The Keor DK 6000VA UPS is an advanced uninterruptible power supply solution designed for critical applications that require maximum reliability and energy efficiency. This single-phase double conversion system guarantees total protection against power cuts, fluctuations and electrical disturbances, ensuring the operational continuity of sensitive equipment in industrial, commercial and IT environments.- Active output power of 6000W and apparent power of 6000VA, allowing to power demanding loads with an output power factor 1, optimizing the actual use of available energy.- Input voltage range from 176V to 280V and regulated output between 200V to 240V, adapting to network variations and providing a stable and safe power supply.- Input frequency from 45Hz to 65Hz and output from 50Hz to 60Hz, compatible with international standards and adaptable to different electrical environments.- Double conversion online technology (ISV), which completely isolates the load from any anomaly in the electrical network, ensuring superior power quality.- Total efficiency of 95.1% and eco mode with efficiency of 99%, which significantly reduces energy consumption and operating costs, contributing to environmental sustainability.- Maximum voltage distortion at the output less than 2% under linear load, ensuring a clean and stable power supply for sensitive electronic equipment.- Includes internal VRLA type battery (rechargeable accumulator), with 20 individual elements, located inside the UPS itself, which facilitates installation and maintenance.- Compatible with lithium and VRLA batteries, offering flexibility to adapt to different autonomy needs and life cycles.- Eight IEC C13 output sockets and two IEC C19, in addition to a terminal output, allowing the direct connection of multiple critical devices and systems.- Fixed input connection, guaranteeing a safe and robust installation.- USB and RS232 communication interface, as well as SNMP capability, allowing remote monitoring, integration into network management systems and advanced UPS control.- Network management capability and switching contact without potential, facilitating integration into automation infrastructures and alert systems.- Automatic disconnection function to protect the load and the UPS itself from anomalous situations.- Touch LCD control panel, intuitive and easy to use, which provides clear information and quick navigation through interactive icons.- Compact design with dimensions of 176x440x700mm, optimizing space in technical rooms or racks.- Weight of 54kg, suitable for fixed and robust installations.- Noise level of 45dB, allowing its use in environments where noise is a critical factor.- IP20 protection degree, suitable for protected indoor installations.- Operating temperature from 0°C to 40°C and storage from -10°C to 50°C, ensuring reliability in a wide range of environmental conditions.- Nominal current of 33A, Suitable for high demand loads.- Universal load type, compatible with a wide variety of equipment and systems.- Includes indication of marks on the connection terminals to facilitate installation and safe maintenance.- Non-modular, which simplifies configuration and reduces potential failure points.- No additional electrical power socket, prioritizing the safety and robustness of the installation.- Complies with the IEC designation for VRLA batteries, ensuring international quality and safety standards.- Industrial classification (non-portable), ideal for professional applications and environments where reliability is a priority. Competitive and differential advantages:- Unit power factor (kVA=kW), which maximizes the actual power available for the connected load, surpassing many conventional UPS.- Class-leading efficiency, with up to 96% in normal operation and 99% in eco mode, reducing energy consumption and associated costs.- Compatibility with lithium batteries and VRLA, allowing to choose the most appropriate technology according to the needs of autonomy, maintenance and life cycle.- Easy to use touch LCD panel, which simplifies system supervision and configuration, improving the user experience and reducing intervention times.- Simple Plug&Play type installation; and easy maintenance thanks to hot-swappable battery blocks, minimizing downtime.- Convertible for tower or rack use, adapting to different configurations of technical room or data center.- Advanced network management and remote monitoring, easily integrating into IT infrastructures and centralized management systems.- Total protection against electrical anomalies, guaranteeing continuity of service in critical applications such as servers, telecommunications systems, medical equipment, industrial automation and security systems. The Keor DK 6000VA UPS is the ideal choice for those looking for a robust, efficient and flexible solution for the protection of critical equipment, combining cutting-edge technology, ease of use and an excellent ratio between performance and operating cost.
| Input Voltage (Min-Max) | 176-280 V |
|---|
| Primary Frequency (Min-Max) | 45-65 Hz |
|---|
| Number of primary phases | 1 |
|---|
| Output Voltage (Min-Max) | 200-240 V |
|---|
| Secondary Frequency (Min-Max) | 50-60 Hz |
|---|
| Active power output | 6000 W |
|---|
| Apparent power output | 6000 VA |
|---|
| Power consumption | 101 W |
|---|
| USB interface | Yes |
|---|
| With RD 232 communication interface | Yes |
|---|
| Number of secondary phases | 1 |
|---|
| SNMP | Yes |
|---|
| Type of voltage | AC |
|---|
| Height | 176 mm |
|---|
| Width | 440 mm |
|---|
| Depth | 700 mm |
|---|
| Weight | 54 kg |
|---|
| Network management capability | Yes |
|---|
| ISV Technology | Online |
|---|
| Modulate | No |
|---|
| Max. voltage distortion at output (linear load) | 2 % |
|---|
| Power Factor at Output | 1 |
|---|
| Total efficiency | 95.1 % |
|---|
| Efficiency in Eco mode | 99 % |
|---|
| Potential-free switching contact | Yes |
|---|
| Automatic switch-off function | Yes |
|---|
| Input socket | Fixed connection |
|---|
| Number of C13 outlet outlets | 8 |
|---|
| Number of C19 outlet sockets | 2 |
|---|
| Number of fixed-type output sockets | 1 |
|---|
| Protection Class (IP) | IP20 |
|---|
| Operating Temperature (Min-Max) | 0-40 °C |
|---|
| Storage Temperature (Min-Max) | -10-50 °C |
|---|
| Rated Current (Min-Max) | 33-33 A |
|---|
| Sound Level | 45 dB |
|---|
| Display of markings on the connection terminals | Yes |
|---|
| Load Type | Universal |
|---|
| With electrical outlet | No |
|---|
| Contains battery and/or accumulator | Yes |
|---|
| IEC Designation | VRLA |
|---|
| Battery or accumulator (Pack1) | Accumulator (rechargeable) |
|---|
| Pack Number1 | 1 |
|---|
| Number of individual items (Pack1) | 20 |
|---|
| Location of Pack1 | The product includes a battery |
|---|
| Regulatory Type (Pack1) | I : Industrial (not portable) |
|---|