LEGRAND 028237 - Image 1

Images are for illustrative purposes only. Please refer to data sheet for details.

028237 LEGRAND DMX³1600 50KA S 4P1000A+028302

Code: 028237

Manufacturer: LEGRAND

Description:

DMX³1600 50KA S 4P1000A+028302
Open frame switch DMX³ 1600 - secc - lcu 50kA - size 0 - 4P - ln 1000A, complete with MP4.10 protection unit 028302
DMX³ 1600 secc 50kA 4P 1000A open frame switch with integrated UP

Categories:

  • Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
  • LEGRAND > OPEN FRAME AUTOMATION DMX3

Brand new product in its original packaging covered by the warranties and certifications provided by LEGRAND

  • More Info
  • ETIM
  • Reviews
Guarantee, repair and return.

Unit Price: 5.997,08 €

This price is per unit and is the net value (not including taxes if applicable).

Calculate price by quantity

QuantityPrice

Standard lead time: 15-17 days.

  • These delivery times are an estimate any may vary when the item order has been processed.

LAST VIEWED

MORE INFO

DMX³ open-frame switches enable protection and control at the inlet of low-voltage installations from 630A to 6300A. DMX³-I Load Cut Disconnectors allow low-voltage circuits from 1000A to 6300A to be cut and sectioned under load. These power protection devices are available in a fixed or sectional version and can be equipped with interlocking mechanisms for mains inverters. They can be complemented with auxiliaries such as trigger coils, motorized controls, locks, front or rear sockets, separators. The electronic protection units allow precise adjustments of the protection parameters and must be ordered at the same time as the DMX³ for factory installation. The DMX³ 1600 has a complete version pre-equipped with a protection unit. The protection units can be adjusted directly on the display or in combination with a Bluetooth dongle, the parameters can be adjusted via an app.
Permanent nominal current Iu1000 A
Nominal voltage230-690 V
Rated short-circuit current at the cut-off current Icu at 50 Hz 400 V50 kA
Current Overload Release Setting400-1000 A
Short-Term Short-Circuit Delayed Release Adjustment Range600-10000 A
Short-circuit instantaneous release adjustment range2000-50000 A
Device constructionSliding technology for integrated device
Integrated ground fault protectionYes
Main Current Circuit Connection TypeScrew connection
Suitable for DIN rail mountingNo
Optional DIN rail mountingNo
Number of auxiliary contacts as change contact1
With alarm activatedYes
With integrated low-voltage releaseNo
Number of poles4
Connection position for the main voltage circuitBehind
Execution of the actuator elementPush button
Complete device with protective deviceYes
Integrated motorized driveNo
Optional motorized driveYes
Protection Class (IP)IP30
Width309 mm
Height310 mm
Depth239 mm
Impact resistanceNot applicable
Operating Temperature-25-70 °C
Storage temperature-25-70 °C
Type of voltageAC
frequency50-60 Hz
Direction of the electricity supplyFrom the top or bottom
Display of markings on the connection terminalsNo
ColourGrey
RAL number7035
Halogen-freeYes
Terminal capacity240-600 mm²
Connection Cable TypeFlexible or rigid
Label Space/Print AreaNo
Contains battery and/or accumulatorYes

ETIM for 028237 Low-voltage industrial controls and switchgear (EC000228)

Feature nameDegree of protection (IP) (EF005474)
Feature valueIP30
Feature nameNumber of auxiliary contacts as change-over contact (EF003531)
Feature value1
Feature nameAdjustment range undelayed short-circuit release (EF007131)
Feature value2000 A
Feature nameIntegrated earth fault protection (EF007296)
Feature valueYes
Feature nameWith integrated under voltage release (EF001390)
Feature valueNo
Feature nameSuitable for DIN rail (top hat rail) mounting (EF007250)
Feature valueNo
Feature nameDevice construction (EF008240)
Feature valueBuilt-in device slide-in technique (withdrawable)
Feature nameNumber of poles (EF001391)
Feature value4
Feature nameType of electrical connection of main circuit (EF006819)
Feature valueBolt connection
Feature nameOverload release current setting (EF002336)
Feature value400 A
Feature nameMotor drive integrated (EF006697)
Feature valueNo
Feature nameAdjustment range short-term delayed short-circuit release (EF007129)
Feature value600 A
Feature nameType of control element (EF006976)
Feature valuePush button
Feature nameRated short-circuit breaking capacity Icu at 400 V, 50 Hz (EF007048)
Feature value50 kA
Feature nameRated permanent current Iu (EF001389)
Feature value1000 A
Feature nameWith switched-off indicator (EF007006)
Feature valueYes
Feature nameMotor drive optional (EF007386)
Feature valueYes
Feature namePosition of connection for main current circuit (EF006671)
Feature valueBack
Feature nameRated voltage (EF003977)
Feature value230 V
Feature nameDIN rail (top hat rail) mounting optional (EF008904)
Feature valueNo
Feature nameComplete device with protection unit (EF008906)
Feature valueYes

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.