611403 LAPP ÖLFLEX POWER MULTI 3G14AWG View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

611403 LAPP ÖLFLEX POWER MULTI 3G14AWG

611403

LAPP

1 m.

ÖLFLEX POWER MULTI 3G14AWG

ÖLFLEX® POWER MULTI

More details


ÖLFLEX PUR/TPE coloured

Brand new product in its original packaging covered by the warranties and certifications provided by LAPP

Total: $11.02
Unit price: $11.02/m
This price is per unit and is the net value (not including taxes if applicable).
* This article may be obsolete.

Go to successor article: 611405 611405

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Benefits

  • Suitability for different operation types and locations in the USA as per NFPA/ NEC under one LAPP part number, thanks to UL listings (UL) STOOW and (UL) TC, resp. TC-ER, as well as thanks to design and characteristics associated with these listings
  • Apart from unprotected laying on tray in the USA thanks to TC(-ER) listing: ...further, normatively specified, unprotected wiring methods in the USA per application related NEC Articles, thanks to (UL) listing STOOW/ Extra-hard usage Flexible Cord

Application range

  • Industrial machinery, plant engineering in the USA
  • Unprotected 600V operation on cable tray in the USA, incl. 6 ft. Exposed Run laying sections for version with at least 3 conductors
  • As per Article 400 of NEC/ NFPA 70: General Uses Permitted in the USA and General Uses Not Permitted to the overall group of Flexible Cords and Flexible Cables acc. to UL 62;
    Operating bids and limitations for Flexible Cords in special applications acc. to further NEC Articles, such as 501 (Class I Locations), 422 (Appliances), or 520 (specific locations for play and production of entertainment), etc.
  • Further, typical locations in the USA, as specified by respective US installation standardization (e.g., NEC/ NFPA 70): Power cord for equipment, paint booths, appliances, factory installations (branch circuit), any power hook-up in the plant, for harnessed power connecting or extension cord set assemblies
  • In hazardous locations in the USA, as per Chapter 5 of NEC/ NFPA 70: Classes I thru III, Divisions 1 and 2 each, plus intrinsically safe circuits, taking account of:
    - Provisions on cable design, cable type, installation, application in NEC Chapter 5 (esp.: Articles 500 thru 504);
    - This cable's design, approvals, component identification

Product features

  • Highly flame retardant FT4
  • Highly oil resistant OIL RES I/II
  • Tested sunlight resistant per UL 1277, UL 62, UL 2556 in terms of UV resistance
  • Tested for unprotected, direct burial in the USA per UL 1277

Norm references / Approvals

  • Certified by UL per UL 1277 for TC 600V use in the USA, subject to individual third-party inspection: Generally UL Type TC (Tray Cable), and for at least 3 or more conductors TC-ER (Tray Cable for Exposed Run) in addition [UL CCN: QPOR; UL File No.: E171371]
  • Certified by UL per UL 62 for STOOW use in the USA, subject to individual third-party inspection: UL Type STOOW (Extra-hard usage Flexible Cord) [UL CCN: ZJCZ; UL File No.: E146118]
  • Certified by UL per CSA C22.2 No. 239, and CSA C22.2 No. 230 for possible CIC/TC use in Canada, subject to individual third-party inspection: c(UL) CIC/TC FT4 [UL CCN: QPOR7; UL File No.: E171371]
  • Certified by UL per CSA C22.2 No. 49 for STOOW use in Canada, subject to individual third-party inspection: c(UL) STOOW [UL CCN: ZJCZ7; UL File No.: E146118]
  • Certified by CSA per CSA C22.2 No. 210 for AWM use in Canada, subject to individual third-party inspection: CSA AWM II A/B FT4

Product Make-up

  • Fine-wire strand made of bare copper wires
  • Specially formulated PVC insulation
  • Durable, black sheath made of specially formulated thermoplastic polymer for improved service life

Classification ETIM 5

  • ETIM 5.0 Class-ID: EC001578
  • ETIM 5.0 Class-Description: Flexible cable

Classification ETIM 6

  • ETIM 6.0 Class-ID: EC001578
  • ETIM 6.0 Class-Description: Flexible cable

Core identification code

  • - Coloured conductors with numbers, plus ground in green/yellow (30 % stripe width);
    - For 2-conductor cable only: No green/ yellow ground
    - Example 3 conductors:
    BLACK conductor: "1 - ONE"
    WHITE conductor: "2 - TWO"
    GREEN/YELLOW conductor: No Numbers
  • - Colour code:
    2C: Black, White
    3C: Black, White, Green-Yellow
    4C: Black, White, Red, Green-Yellow
    5C: Black, White, Red, Brown, Green-Yellow
    6C or more: Black with white numbers, except for the included Green-Yellow ground

Conductor stranding

  • Fine wire according to DIN EN 60228 (VDE 0295), class 5 / IEC 60228 class 5

Minimum bending radius

  • Installation: 4 x outer diameter

Nominal voltage

  • UL/CSA TC/STOOW: 600 V
  • IEC U0/U: 300/500 V

Test voltage

  • 2000 V

Protective conductor

  • G = with GN-YE protective conductor

Temperature range

  • UL/CSA TC: -25°C to +90°C;
  • Occasional flexing/ North America: -25°C to +105°C;
    Fixed installation/ North America: -40°C to 105°C

Datasheet - PDF

Title: Size: Type:
PDF CATALOGUE LAPP EN.pdf 69 Mbytes
611403 611403 EN_611405.pdf 353 Kbytes   611403  611403 EN_611405.pdf

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.