1023761 LAPP H1Z2Z2-K, OPTIMIZED VERSION 1X10 BK View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

1023761 LAPP H1Z2Z2-K, OPTIMIZED VERSION 1X10 BK

1023761

LAPP

1 m.

H1Z2Z2-K, OPTIMIZED VERSION 1X10 BK

H1Z2Z2-K, optimized version

More details


ÖLFLEX SOLAR cabling

Brand new product in its original packaging covered by the warranties and certifications provided by LAPP

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Benefits

  • Reduction of flame propagation and of toxic combustion gases in the event of fire
  • Robust against mechanical impacts
  • For outdoor applications
  • Inside the EU, and particularly on site, applicable for many building types as per local, legal implementation of EU CPR - Construction Product Regulation (EU) No. 305/2011, thanks to Dca Classification
  • 25 years in expectable lifespan under normal use conditions as defined in EN 50618

Application range

  • For free and stationary or for freely suspended outdoor and indoor cabling between the solar modules, or between the module strings and the DC/AC inverter, for example in line with HD 60364-7-712 on PV systems, and EN 50618 on H1Z2Z2-K cable type, etc....; Short circuit and earth fault protected per EN 50618, Annex A, and per HD 60364-5-52
  • Photovoltaic systems with DC system voltage up to 1800 V to ground
  • As per EN 50618, Annex A, inside electrical installation pipe/ duct/ channel, plaster, and appliance, as well as inside or connected to double insulated/ protected appliance or system of protection class II
  • AD8: Permanent water contact and submersion down to 1 metre in water depth
  • Increased, mechanical robustness, for instance in the event of impact, with regard to assessed, burial based Impact-Resistance Test and Crushing-Resistance Test per UL 854

Product features

  • Weather/ UV resistant per EN 50618, Annex E, as well as ozone resistant per EN 50396;
    Transversely watertight "AD8" per IEC 60364-5-51/ HD 60364-5-51, IEC 62440, and EN 50525-2-21 down to 1 metre in water depth
  • Flame retardant per IEC 60332-1-2, and Dca classified per EU CPR - Construction Product Regulation (EU) No. 305/2011
  • Halogen-free according to IEC 60754-1 (amount of halogen acid gas),
    Low Corrosiveness of combustion gases according to IEC 60754-2 (degree of acidity)
  • Good notch and abrasion resistance
  • Tested against burial-related, mechanical UL 854 Tests Impact-Resistance and Crushing-Resistance

Norm references / Approvals

  • H1Z2Z2-K type certified according to EN 50618
  • Items with other cross-sections on request

Product Make-up

  • Fine-wire, tinned-copper conductor
  • Coreinsulation made of cross-linked copolymer
  • Outer sheath made of cross-linked copolymer
  • Outer sheath colour: black, red or blue
  • Further single colours for the outer sheath on request

Classification ETIM 5

  • ETIM 5.0 Class-ID: EC001578
  • ETIM 5.0 Class-Description: Flexible cable

Classification ETIM 6

  • ETIM 6.0 Class-ID: EC001578
  • ETIM 6.0 Class-Description: Flexible cable

Conductor stranding

  • Fine wire according to VDE 0295,
    class 5/IEC 60228 class 5

Minimum bending radius

  • 4 x OD

Nominal voltage

  • AC U0/U: 1.0/1.0 kV
    DC U0/U: 1.5/1.5 kV
    Max. permissible DC operating voltage: 1.8 kV

Test voltage

  • AC 6500 V
  • DC 15000 V

Current rating

  • Im compliance with EN 50618, Table A.3
  • Acc. to EN 50618, reduction factors for clustered wiring per... HD 60364-5-52

Temperature range

  • >Conductor..., max., per EN 60216-1: 120°C;
    >Conductor..., max., short-circuit/ earth fault (period of max. 5 s): 250°C;
    >Ambient..., min., stationary use: -40°C;
    >Ambient..., min., flexible use or during installation: -25°C;
    >Ambient..., max., in conjunction with EN 60216-1: 90°C;
    >Ambient..., constant, in conjunction with HD 60364-7-712: 70°C to 90°C;
    >Ambient..., ambient temp. related reduction factor 1.00: 60°C;
    >Ambient..., max., storage: 40°C

Datasheet - PDF

Title: Size: Type:
PDF CATALOGUE LAPP EN.pdf 69 Mbytes
1023761 1023761 EN_1023761.pdf 640 Kbytes   1023761  1023761 EN_1023761.pdf

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.