ÖLFLEX 191 CY 9G 1.5

ÖLFLEX® 191 CY

More details


ÖLFLEX PVC cable AWM recognized

Brand new product in its original packaging covered by the warranties and certifications provided by LAPP

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



ÖLFLEX® 191, UL/CSA AWM certified control cable, oil resistant, shielded and flexible for various applications, UL/CSA: 600 V

  • Cross section of conductors up to 120 mm²
  • For sections 0.75 mm² see ÖLFLEX® 150 CY
  • Oil resistant, according to EN 50363-4-1: TM5

proceeds

  • Excellent electrical performance, with a test voltage of 4 kV
  • Multifunctional cable

Scope of use

  • Plant Engineering
    Industrial machinery
    Air conditioning installations
  • In critical EMC (electromagnetic compatibility) environments
  • Dry, wet and wet indoors (including mixtures of water and oils), but not suitable for outdoor use
  • For fixed installations under conditions of medium mechanical load, as well as with occasional movement in non-concurrent or continuous bending; no traction load or forced guidance
  • Note: Use of AWM (Appliance Wiring Material) cables in industrial machines (USA) according to NFPA 79: see catalog annex, Table T29

Product features

  • Non-flame propagator according to IEC 60332-1-2 and UL 1581 §1061 Flame Test Cable
  • Oil resistant, according to EN 50363-4-1: TM5
  • High percentage of screen coverage with low transfer impedance (max. 250 Ω/km at 30 MHz)

Reference Standards / Approvals

  • UL AWM Style 21098
    CSA AWM I A/B II A/B
  • Cables according to IEC and American standard have braided conductors with nominal sizes in mm² or AWG/kcmil. The main size is mentioned in the table below, and the equivalent size of the other system can be found in Appendix T16 of this catalog. for this related secondary size the cross-section of the conductor is usually greater than the specified nominal value

Product composition

  • Conductor formed by fine stranded bare copper wires braided
  • PVC insulation
  • Layered braided conductors
  • PVC inner cover, grey
  • Tinned copper braid screen
  • Cover: PVC, with improved oil resistance, gray (similar to RAL 7001)

ETS Classification 5

  • ETIM 5.0 Class-ID: EC000104
  • ETIM 5.0 Class Description: Control Cable

ETTIM Rating 6

  • ETIM 6.0 Class-ID: EC000104
  • ETIM 6.0 Class-Description: Control Line

Driver Identification Code

  • Black with white numbers according to VDE 0293-334

Driver training

  • Fine threads braided according to
    VDE 0295 Class 5 / IEC 60228 Class 5

Minimum radius of curvature

  • Occasional flexible use: 20 x outside diameter
  • Fixed installation: 6 x outer diameter

Nominal voltage

  • HAR U0/U: 300/500 V
  • UL/CSA: 600 V

Test voltage

  • 4000 V

Protective conductor

  • G = with AM/VE protection conductor
  • X = no protective conductor

Temperature range

  • Occasional bending: -5°C to +70°C; UL/CSA: -5°C to +90°C
  • Fixed installation: -40 °C to +70 °C UL/CSA: +90 °C

Datasheet - PDF

Title: Size: Type:
PDF CATALOGUE LAPP EN.pdf 69 Mbytes

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.