EATON - MOELLER PLSM-B20/4-MW 242587 Y7-242587 - Image 1

Images are for illustrative purposes only. Please refer to data sheet for details.

PLSM-B20/4-MW 242587 Y7-242587 EATON ELECTRIC Over current switch, 20A, 4p, type B characteristic

Reference: PLSM-B20/4-MW

Code: 242587

Catalog Number: Y7-242587

Manufacturer: EATON - MOELLER

Description:

Over current switch, 20A, 4p, type B characteristic
PLSM-B20/4-MW
Eaton Moeller series xPole - PLS6/M MCB. PLSM, 4 pole, tripping characteristic: B, rated current In: 20 A, rated switching capacity IEC/EN 60898-1: 10 kA
Miniature circuit breaker (MCB), PLSM, 4 pole, tripping characteristic: B, rated current In: 20 A, rated switching capacity according to IEC/EN 60898-1: 10 kA, Switchgear for residential and commercial applications

Categories:

  • Circuit breakers and fuses > Miniature circuit breaker (MCB)
  • EATON - MOELLER > Modular Switchgear – Industrial

Brand new product in its original packaging covered by the warranties and certifications provided by EATON - MOELLER

  • More Info
  • ETIM
  • PDF
  • Reviews
Guarantee, repair and return.

Unit Price: 139,45 €

This price is per unit and is the net value (not including taxes if applicable).

Calculate price by quantity

QuantityPrice

Standard lead time: 5 days.

  • These delivery times are an estimate any may vary when the item order has been processed.

LAST VIEWED

MORE INFO

General specifications

Product Name
Eaton Moeller series xPole - PLS6/M MCB
Catalog Number
242587
Model Code
PLSM-B20/4-MW
EAN
4015082425876
Product Length/Depth
80 mm
Product Height
75 mm
Product Width
70 mm
Product Weight
0.418 kg
Compliances
RoHS conform

Product specifications

Type
Special features
Ambient temperature hint: a 1 °C increase results in a 0.5% linear reduction of current carrying capacity
Application
  • Switchgear for residential and commercial applications
  • xPole - Switchgear for residential and commercial applications
Amperage Rating
20 A
Features
Additional equipment possible
Concurrently switching N-neutral
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
Pollution degree
2
Used with
Miniature circuit breaker
PLSM
Degree of protection
IP20
Equipment heat dissipation, current-dependent
12.8 W
Rated impulse withstand voltage (Uimp)
4 kV
Tripping characteristic
B
Ambient operating temperature - max
75 °C
Ambient operating temperature - min
-25 °C
Built-in depth
70.5 mm
Connectable conductor cross section (multi-wired) - max
25 mm²
Connectable conductor cross section (multi-wired) - min
1 mm²
Connectable conductor cross section (solid-core) - max
25 mm²
Connectable conductor cross section (solid-core) - min
1 mm²
Current limiting class
3
Frequency rating - max
60 Hz
Frequency rating - min
50 Hz
Heat dissipation capacity
0 W
Heat dissipation per pole, current-dependent
0 W
Width in number of modular spacings
4
Voltage type
AC
Overvoltage category
III
Number of poles
Four-pole
Release characteristic
B
Number of poles (protected)
4
Number of poles (total)
4
Rated insulation voltage (Ui)
440 V
Rated operational current for specified heat dissipation (In)
20 A
Rated operational voltage (Ue) - max
400 V
Rated short-circuit breaking capacity (EN 60898) at 230 V
10 kA
Rated short-circuit breaking capacity (EN 60898) at 400 V
10 kA
Rated short-circuit breaking capacity (IEC 60947-2) at 230 V
0 kA
Rated short-circuit breaking capacity (IEC 60947-2) at 400 V
0 kA
Rated switching capacity (IEC/EN 60898-1)
10 kA
Static heat dissipation, non-current-dependent
0 W
Power loss
10.5 W

ETIM for 242587 Circuit breakers and fuses (EC000042)

Feature nameBuilt-in depth (EF000218)
Feature value70.5 mm
Feature nameRelease characteristic (EF000889)
Feature valueB
Feature nameNumber of poles (total) (EF008618)
Feature value4
Feature nameNumber of protected poles (EF005548)
Feature value4
Feature nameRated current (EF000227)
Feature value20 A
Feature nameRated voltage (EF000228)
Feature value400 V
Feature nameRated insulation voltage Ui (EF001366)
Feature value440 V
Feature nameRated impulse withstand voltage Uimp (EF011980)
Feature value4 kV
Feature nameRated short-circuit breaking capacity Icn according to EN 60898 at 230 V (EF009556)
Feature value10 kA
Feature nameVoltage type (EF000187)
Feature valueAC
Feature nameRated short-circuit breaking capacity Icn according to EN 60898 at 400 V (EF009555)
Feature value10 kA
Feature nameRated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V (EF009557)
Feature value0 kA
Feature nameRated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V (EF009558)
Feature value0 kA
Feature nameFrequency (EF000416)
Feature value50 Hz
Feature namePower loss (EF005387)
Feature value10.5 W
Feature nameCurrent limiting class (EF002568)
Feature value3
Feature nameFlush-mounted installation (EF007517)
Feature valueNo
Feature nameConcurrently switching neutral conductor (EF005997)
Feature valueYes
Feature nameOver voltage category (EF002569)
Feature value3
Feature namePollution degree (EF002570)
Feature value2
Feature nameAdditional equipment possible (EF008148)
Feature valueYes
Feature nameWidth in number of modular spacings (EF002950)
Feature value4
Feature nameDegree of protection (IP) (EF005474)
Feature valueIP20
Feature nameAmbient temperature during operating (EF007515)
Feature value-25 °C
Feature nameConnectable conductor cross section multi-wired (EF007343)
Feature value1 mm²
Feature nameConnectable conductor cross section solid-core (EF007337)
Feature value1 mm²
Feature nameExplosion-proof (EF004663)
Feature valueNo

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.