PHOENIX CONTACT  AXL F CNT2 INC2 1F 2688093 - Image 1

Images are for illustrative purposes only. Please refer to data sheet for details.

AXL F CNT2 INC2 1F 2688093 PHOENIX CONTACT Special function module

Reference: AXL F CNT2 INC2 1F

Code: 2688093

Manufacturer: PHOENIX CONTACT

Description:

Special function module
AxiolineF, Function module, Counter input for 24 V signals:2, Transmitter inputs of incremental value:2, Symmetrical and asymmetric transmitters, Digital inputs:8, 24 VDC, Digital outputs:2, 24 VDC, transmission speed on the local bus:100 MBit/s, protection index:IP20, including bus socket module and AxiolineF connectors

Categories:

  • PLC's > Fieldbus, decentr. periphery - function-/technology module
  • PHOENIX CONTACT > I/O

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX CONTACT

  • More Info
  • ETIM
  • PDF
  • Reviews
Guarantee, repair and return.

Unit Price: 474,37 €

This price is per unit and is the net value (not including taxes if applicable).

Calculate price by quantity

QuantityPrice

Standard lead time: 2-3 weeks.

  • These delivery times are an estimate any may vary when the item order has been processed.

MORE INFO

Key Commercial Data

Orderkey2688093
Packing unit1 pc
Catalog pagePage 121 (C-6-2017)
GTIN4046356501439
Weight per Piece (excluding packing)255.000 g
Custom tariff number85389091
Country of originDE (Germany)

Dimensions

Dimensional drawing
Width53.6 mm
Height126.1 mm
Depth54 mm
Note on dimensionsThe depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).

Ambient conditions

Ambient temperature (operation)-25 °C ... 60 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)5 % ... 95 % (non-condensing)
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protectionIP20

General

Mounting typeDIN rail
Net weight255 g
Note on weight specificationswith connectors and bus base module
Diagnostics messagesShort-circuit / overload of the digital outputs Yes
Error at the symmetrical incremental encoder Yes

Interfaces

DesignationAxioline F local bus
No. of channels2
Connection methodBus base module
Transmission speed100 Mbps

Axioline potentials

DesignationAxioline F local bus supply (UBus)
Supply voltage5 V DC (via bus base module)
Current consumptiontyp. 100 mA
max. 120 mA
Power consumptiontyp. 0.5 W
max. 0.6 W
DesignationSupply voltage input UI
Supply voltage24 V DC
Supply voltage range19.2 V DC ... 30 V DC including all tolerances, including ripple
Current consumptionmax. 2.5 A (dependent on the encoder or sensor type used and the load on the digital output.)
Power consumptionmax. 60 W (of which 1.6 W internal losses)
Type of protectionSurge protection of the supply voltage
Polarity reversal protection of the supply voltage
Protectionmax. 8 A (polarity reversal protection up to 5 A)

Counter inputs

Input nameCounter input for 24 V signals
Number of inputs2 (S1, S2)
Description of the inputEN 61131-2, type 3
Connection methodPush-in connection
Input voltage24 V DC
Input voltage range "0" signal-3 V DC ... 5 V DC
Input voltage range "1" signal11 V DC ... 30 V DC
Input frequencymax. 300 kHz (1 channel wired)
max. 100 kHz (More than one channel wired or Z signal monitoring via the firmware)
Input current2.5 mA (per channel)
Resolution32 bits
Permissible cable length to the sensor30 m

Encoder inputs

Input nameIncremental encoder inputs
Number of inputs2 (A1, /A1, B1, /B1, Z1, /Z1; A2, /A2, B2, /B2, Z2, /Z2)
Connection methodPush-in connection
Encoder signalsSymmetrical and asymmetrical encoders
Cable length30 m

Encoder data

Number of 5 V encoder supplies2 (UE1, UE2)
Nominal output voltage5 V DC
Voltage range5 V DC ... 5.5 V DC
Current carrying capacitymax. 250 mA
Type of protectionShort-circuit protection
Number of 24 V encoder supplies2 (US1, US2)
Nominal output voltage24 V DC
Voltage range19.2 V DC ... 30 V DC
Current carrying capacitytyp. 500 mA
Type of protectionShort-circuit protection
DesignationSymmetrical incremental encoders
Encoder types that can be connectedmax. 2 (A, /A, B, /B, (Z, /Z))
Type of connection of signalsPush-in connection
Encoder supply voltage5 V DC
24 V DC
Signal voltage levelDifferential signal (signal – inverted signal) ±0.5 V, minimum; ±6 V, maximum
Common mode voltage range signal - ground-10 V ... 13.2 V
Input frequencymax. 300 kHz (1 channel wired)
max. 100 kHz (More than one channel wired or Z signal monitoring via the firmware)
DesignationAsymmetrical incremental encoders
Encoder types that can be connectedmax. 2 (A, B, (Z))
Type of connection of signalsPush-in connection
Signal voltage levelLow ≤ 2.5 V, high ≥ 3.5 V (up to 27 V, maximum)
Input frequencymax. 300 kHz (1 channel wired)
max. 100 kHz (More than one channel wired or Z signal monitoring via the firmware)

Digital inputs

Input nameDigital inputs
Description of the inputEN 61131-2, type 3
Connection methodPush-in connection
Connection technology1-wire (optionally 2, 3-wire)
Number of inputs8 (CNT: G1, G2, Dir1, Dir2; INC: Ref1, Ref2, L1, L2)
Input voltage range "0" signal-3 V DC ... 5 V DC
Input voltage range "1" signal11 V DC ... 30 V DC
Nominal input current at UIN2.5 mA (per channel)

Digital outputs

Output nameDigital outputs
Connection methodPush-in connection
Connection technology1-wire
Number of outputs2 (Out1, Out2)
Type of protectionShort-circuit protection, overload protection of the outputs
Output voltage24 V DC
Nominal output voltage24 V DC
Maximum output current per channel500 mA
Nominal load, inductivemax. 12 VA (1.2 H, 48 Ω, with nominal voltage)
Nominal load, lampmax. 12 W (at nominal voltage)
Nominal load, ohmicmax. 12 W (48 Ω, with nominal voltage)

Electrical isolation

Test section5 V communications power (logic), 24 V supply (I/O) 500 V AC 50 Hz 1 min.
5 V supply (logic)/functional earth ground 500 V AC 50 Hz 1 min.
24 V supply (I/O) / functional earth ground 500 V AC 50 Hz 1 min.

Standards and Regulations

Mechanical testsVibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
Shock in acc. with EN 60068-2-27/IEC 60068-2-27 30g
Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g
Protection classIII, IEC 61140, EN 61140, VDE 0140-1

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications

ETIM for 2688093 PLC's (EC001601)

Feature nameSupply voltage DC (EF007534)
Feature value19.2 V
Feature nameNumber of functions (EF003244)
Feature value2
Feature nameNumber of HW-interfaces industrial Ethernet (EF003020)
Feature value0
Feature nameNumber of interfaces PROFINET (EF006932)
Feature value0
Feature nameNumber of HW-interfaces RS-232 (EF003021)
Feature value0
Feature nameNumber of HW-interfaces RS-422 (EF003022)
Feature value0
Feature nameNumber of HW-interfaces RS-485 (EF003023)
Feature value0
Feature nameNumber of HW-interfaces serial TTY (EF003024)
Feature value0
Feature nameNumber of HW-interfaces parallel (EF003026)
Feature value0
Feature nameNumber of HW-interfaces wireless (EF006933)
Feature value0
Feature nameNumber of HW-interfaces USB (EF003025)
Feature value0
Feature nameNumber of HW-interfaces other (EF003027)
Feature value0
Feature nameWith optical interface (EF003028)
Feature valueNo
Feature nameSupporting protocol for EtherCAT (EF017564)
Feature valueNo
Feature nameSupporting protocol for TCP/IP (EF003050)
Feature valueNo
Feature nameSupporting protocol for PROFIBUS (EF003052)
Feature valueYes
Feature nameSupporting protocol for CAN (EF003053)
Feature valueNo
Feature nameSupporting protocol for INTERBUS (EF003054)
Feature valueNo
Feature nameSupporting protocol for ASI (EF003051)
Feature valueNo
Feature nameSupporting protocol for KNX (EF003055)
Feature valueNo
Feature nameSupporting protocol for Modbus (EF003057)
Feature valueNo
Feature nameSupporting protocol for Data-Highway (EF003058)
Feature valueNo
Feature nameSupporting protocol for DeviceNet (EF003059)
Feature valueNo
Feature nameSupporting protocol for SUCONET (EF003060)
Feature valueNo
Feature nameSupporting protocol for LON (EF003017)
Feature valueNo
Feature nameSupporting protocol for PROFINET IO (EF007525)
Feature valueNo
Feature nameSupporting protocol for PROFINET CBA (EF007524)
Feature valueNo
Feature nameSupporting protocol for SERCOS (EF006657)
Feature valueNo
Feature nameSupporting protocol for Foundation Fieldbus (EF007522)
Feature valueNo
Feature nameSupporting protocol for EtherNet/IP (EF007521)
Feature valueNo
Feature nameSupporting protocol for AS-Interface Safety at Work (EF007519)
Feature valueNo
Feature nameSupporting protocol for DeviceNet Safety (EF007520)
Feature valueNo
Feature nameSupporting protocol for INTERBUS-Safety (EF006662)
Feature valueNo
Feature nameSupporting protocol for PROFIsafe (EF007526)
Feature valueNo
Feature nameSupporting protocol for SafetyBUS p (EF007527)
Feature valueNo
Feature nameSupporting protocol for other bus systems (EF003062)
Feature valueNo
Feature nameIO link master (EF007298)
Feature valueNo
Feature nameSystem accessory (EF004118)
Feature valueYes
Feature nameFunction block restart blockage (EF007212)
Feature valueNo
Feature nameFunction block automatic reset (EF007208)
Feature valueNo
Feature nameContactor control function block (EF007467)
Feature valueNo
Feature nameFunction block emergency stop (EF007211)
Feature valueNo
Feature nameFunction block contactless working protection installation (EF007209)
Feature valueNo
Feature nameFunction block affirm push button (EF007214)
Feature valueNo
Feature nameFunction block 2-hand switching (EF007215)
Feature valueNo
Feature nameFunction block operating mode selection (EF007210)
Feature valueNo
Feature nameFunction block access control (EF007213)
Feature valueNo
Feature nameDegree of protection (IP) (EF005474)
Feature valueIP20
Feature nameFieldbus connection over separate bus coupler possible (EF004002)
Feature valueYes
Feature nameFrequency measurement (EF000599)
Feature valueYes
Feature nameSuitable for rail mounting (EF003972)
Feature valueYes
Feature nameWall mounting/direct mounting (EF007020)
Feature valueNo
Feature nameFront built-in possible (EF007016)
Feature valueNo
Feature nameRack-assembly possible (EF007018)
Feature valueNo
Feature nameSuitable for safety functions (EF001597)
Feature valueNo
Feature nameSIL according to IEC 61508 (EF009889)
Feature valueNone
Feature namePerformance level according to EN ISO 13849-1 (EF007399)
Feature valueNone
Feature nameAppendant operation agent (Ex ia) (EF004141)
Feature valueNo
Feature nameAppendant operation agent (Ex ib) (EF004142)
Feature valueNo
Feature nameExplosion safety category for gas (EF003997)
Feature valueNone
Feature nameExplosion safety category for dust (EF003998)
Feature valueNone

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.