SIEMENS

Siemens is a global powerhouse in industrial automation and electrification, present in over 190 countries. Their product portfolio is the most extensive on the market, covering everything from power distribution and control to digital factory solutions. For the electrical engineer, Siemens offers a comprehensive range of industrial control comp...

7ML5440-1EA00-1BB1 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-1EA00-1BB1
Reference: 7ML5440-1EA00-1BB1
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 100m (328 ft) max range, -40 C degrees to +200 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 4" / 100 mm, 316L stainless steel Enclosure (with cable inlet): Stainless Steel, 1 X 1/2" NPT . Label: Sitrans LR560 Pressure Rating: 3 bar g (40 psi g) maximum Output/communication: PROFIBUS PA Approvals: CSA/FM Class I, Div. 2, Gr. A, B,C,D, Class II, Div.1, Gr. E, F,G, Class III, IC FCC Local display interface: Without LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measuring range and process temperature 100 m max range, -40 ... +200 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 4" / 100 mm, 316L stainless steel Box (with cable entry): Stainless steel, 1 X 1/2" NPT. Label: Sitrans LR560 Pressure: 3 bar g (40 psi g) max. Output/Communications: PROFIBUS PA Approvals: CSA/FM Class I, Div. 2, Gr. A,B,C,D, Class II, Div.1,Gr. E,F,G, Class III, IC FCC User Interface (Local): No LDI (User Interface)
Delivery: See availability
7ML5433-2AA20-1AL0 SIEMENS SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: conti..

SIEMENS

Manufacturer Code: 7ML5433-2AA20-1AL0
Reference: 7ML5433-2AA20-1AL0
Catalog Number: -
SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: continuous, non-contact, 20 m (66 ft) range, for liquids, solids, and slurries. For use in hygienic applications. Hygienic Approvals: EHEDG EL Aseptic Class I Process Connection Types: (all types have TFM1600 PTFE lens): 316L st/st (1.4435 or 1.4404) 2 inch Sanitary Clamp according to ISO 2852 Communication: 4-20mA HART,start-up at < 3.6mA - Enclosure (with Cable Inlets): Aluminum, 2 X M20 x 1.5 A: Approvals: Intrinsically Safe: NEPSI Ex ia IIC T4 Ga, Ex iaD 20 T90 IP67 DIP A20 TA 90C Pressure Rating: Rating per pressure/ temperature curves in instruction manual
SITRANS LR250 Radar Level Transmitter with Encapsulated Horn Antenna and PTFE Lens: Continuous, non-contact, 20 m (66 ft) range measurement for liquids, solids and slurries. For use in hygienic applications. Approvals for hygienic/sanitary requirements: EHEDG EL aseptic Class I Process connection types (all types have TFM1600 PTFE lens): 316L stainless steel (1.4435 or 1.4404): 2 inch sanitary clamp according to ISO 2852 Communications: 4-20mA HART, start at <3.6mA - Box (with cable entry): Aluminum, 2 X M20 x 1.5 A: Approvals: Intrinsic safety: NEPSI Ex ia IIC T4 Ga, Ex iaD 20 T90 IP67 DIP A20 TA 90 C Pressure: See pressure/temperature reduction curves in the operating instructions
Delivery: See availability
7ML5432-0FD20-1AD0 SIEMENS SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: conti..

SIEMENS

Manufacturer Code: 7ML5432-0FD20-1AD0
Reference: 7ML5432-0FD20-1AD0
Catalog Number: -
SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: continuous, non-contact, 20 m (66 ft) range, for liquids and slurries in the chemical industry. Process Connection Material:Stainless steel 1.4404/1.4435 Flanged Process Connection Types (Stainless steel 1.4404/1.4435): 50A 10K JIS B 2220 raised face Communication: 4...20mA HART,start-up at <3.6mA - Enclosure (with Cable inlets): Aluminum, 2 X M20 x 1.5 Antenna Lens Material: TFM 1600 Flush lens Approvals: Non-incendive: CSA/FM Class I, Div. 2, Groups A, B, C, D T5, FCC, Industry Canada Pressure Rating: Rating per pressure/ temperature curves in instruction manual
SITRANS LR250 Radar Level Transmitter with Encapsulated Horn Antenna and PTFE Lens: Continuous, non-contact, 20 m (66 ft) range measurement for liquids and slurries in chemical industry applications. Material, process connection: Stainless steel 1.4404/1.4435 Types of flanged process connection (stainless steel 1.4404/1.4435): 50A 10K JIS B 2220 with highlight Communications: 4...20mA HART, start at <3.6mA - Box (with cable entry): Aluminum, 2 X M20 x 1.5 Lens material (antenna): TFM 1600 recessed lens Approvals: Non-incendiary: CSA/FM Class I, Div. 2, Groups A,B, C, D T5, FCC, Industry Canada Pressure: See pressure/temperature reduction curves in the service instructions
Delivery: See availability
7ML5033-2BA03-2B SIEMENS MultiRanger 200 Ultrasonic level controller: continuous, non-contact, 15 m (50 ft) ..

SIEMENS

Manufacturer Code: 7ML5033-2BA03-2B
Reference: 7ML5033-2BA03-2B
Catalog Number: -
MultiRanger 200 Ultrasonic level controller: continuous, non-contact, 15 m (50 ft) range. Monitors level, volume, and open channel flow in liquids, slurries, and solids. Versions: MultiRanger 200, level, volume, flow and differential measurements Mounting, enclosure design: Wall mount, 4 entries, 4 M20 cable glands included Input voltage: 100 to 230 VAC Number of measurement points: Single point version Data Communications (Smartlinx): Smartlinx Devicenet module Output relays: 6 relays (4 Form A, 2 Form C), 250 V AC Approvals: CSA Class I, Div.2, Group A,B,C and D; Class II, Div.2, Group F and G; Class III
MultiRanger 100/200 Ultrasonic Level Controller: Continuous, non-contact measurement, range 15 m (50 ft). It monitors the level, volume, and flow in open channel of liquids, sludge, and solids. Versions: MultiRanger 200 for level, volume, flow and differential level measurement Mounting, enclosure design: Wall mounting, 4 holes, 4 M20 grommets included Product is in phase out but still available to order, Consider replacing with 7ML5033-xE Input voltage: 100 ... 230 V AC Number of Measurement Points: Single Point Version Data Communication (SmartLinx): SmartLinx DeviceNet Module Output Relays: 6 Relays (4 A-Contacts, 2 C Contacts), 250 V AC Approvals: CSA Class I, Div. 2, Groups A, B, C, and D; Class II, Div. 2, Groups F and G; Class III
Delivery: See availability
7ML5433-2AA20-1AN0 SIEMENS SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: conti..

SIEMENS

Manufacturer Code: 7ML5433-2AA20-1AN0
Reference: 7ML5433-2AA20-1AN0
Catalog Number: -
SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: continuous, non-contact, 20 m (66 ft) range, for liquids, solids, and slurries. For use in hygienic applications. Hygienic Approvals: EHEDG EL Aseptic Class I Process Connection Types: (all types have TFM1600 PTFE lens): 316L st/st (1.4435 or 1.4404) 2 inch Sanitary Clamp according to ISO 2852 Communication: 4-20mA HART,start-up at < 3.6mA - Enclosure (with Cable Inlets): Aluminum, 2 X M20 x 1.5 A: Approvals: Increased Safety: NEPSI Ex e ia mb IIC T4 Ga/Gb , Ex iaD 20 T90 IP67 DIP A20 TA 90C Pressure Rating: Rating per pressure/ temperature curves in instruction manual
SITRANS LR250 Radar Level Transmitter with Encapsulated Horn Antenna and PTFE Lens: Continuous, non-contact, 20 m (66 ft) range measurement for liquids, solids and slurries. For use in hygienic applications. Approvals for hygienic/sanitary requirements: EHEDG EL aseptic Class I Process connection types (all types have TFM1600 PTFE lens): 316L stainless steel (1.4435 or 1.4404): 2 inch sanitary clamp according to ISO 2852 Communications: 4-20mA HART, start at <3.6mA - Box (with cable entry): Aluminum, 2 X M20 x 1.5 A: Approvals: Increased safety: NEPSI Ex e ia mb IIC T4 Ga/Gb, Ex iaD 20 T90 IP67 DIP A20 T A, 90 C Pressure: See pressure/temperature reduction curves in the operating instructions
Delivery: See availability
7ML5433-1FA20-0AL0 SIEMENS SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: conti..

SIEMENS

Manufacturer Code: 7ML5433-1FA20-0AL0
Reference: 7ML5433-1FA20-0AL0
Catalog Number: -
SITRANS LR250 Radar level transmitter with encapsulated horn and PTFE lens: continuous, non-contact, 20 m (66 ft) range, for liquids, solids, and slurries. For use in hygienic applications. Hygienic Approvals: EHEDG EL Class 1 Process Connection Types: 316L st/st (1.4435 or 1.4404) (all types have TFM1600 PTFE lens) Type F (50 mm) Tuchenhagen Varivent EHEDG only Communication: 4-20mA HART,start-up at < 3.6mA - Enclosure (with Cable Inlets):Aluminum, 2 X 1/2 inch NPT A: Approvals: Intrinsically Safe: NEPSI Ex ia IIC T4 Ga, Ex iaD 20 T90 IP67 DIP A20 TA 90C Pressure Rating: Rating per pressure/ temperature curves in instruction manual
SITRANS LR250 Radar Level Transmitter with Encapsulated Horn Antenna and PTFE Lens: Continuous, non-contact, 20 m (66 ft) range measurement for liquids, solids and slurries. For use in hygienic applications. Approvals for hygienic/sanitary requirements: EHEDG EL Class I Process connection types (all types have TFM1600 PTFE lens): 316L stainless steel (1.4435 or 1.4404): Type F (50 mm) Tuchenhagen Varivent EHEDG only Communications: 4-20mA HART, start at <3.6mA - Box (with cable entry): Aluminum, 2 X 1/2 inch NPT A: Approvals: Intrinsic safety: NEPSI Ex ia IIC T4 Ga, Ex iaD 20 T90 IP67 DIP A20 TA 90 C Pressure: See pressure/temperature reduction curves in the operating instructions
Delivery: See availability
7ML5440-0BB00-1BA2 SIEMENS SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monit..

SIEMENS

Manufacturer Code: 7ML5440-0BB00-1BA2
Reference: 7ML5440-0BB00-1BA2
Catalog Number: -
SITRANS LR560: A 2-wire, 78 GHz FMCW radar level transmitter for continuous monitoring of solids and liquids to a range of 100 m (329ft) Order hand programmer separately! Measurement and process temperature range: 40m (131 ft) max range, -40 C degrees to +100 C degrees Process connection: Universal flat-faced flange fits ANSI/DIN/JIS flanges: 4" / 100 mm, 304 stainless steel Enclosure (with cable inlet): Stainless Steel, 1 X M20 x 1.5 (plastic gland included) . Label: Sitrans LR560 Pressure Rating: 3 bar g (40 psi g) maximum Output/communication: PROFIBUS PA Approvals: General purpose, FM, CSA US/C, Industry Canada, FCC, CE, RED, RCM Local display interface: With LDI (local display interface)
SITRANS LR560 Recessed Lens Radar Level Transmitter - continuous, non-contact measurement, 100 m (328 ft) range, for general applications with solids. Measurement range and process temperature: 40 m max. range, -40 ... +100 C Process connection Universal flat face flange compatible with ANSI/DIN/JIS flanges: 4" / 100 mm, 304 stainless steel Box (with cable entry): Stainless steel, 1 X M20 x 1.5 (includes plastic cable gland). Label: Sitrans LR560 Pressure: 3 bar g (40 psi g) max. Output/Communications: PROFIBUS PA Approvals: Ordinary Locations/General Purpose (Non-Ex), FM, cCSAus, IC, FCC, CE, UKCA, RED, RCM User Interface (Local): With LDI (User Interface)
Delivery: See availability

products sitemap