EATON - MOELLER SVX005A1-5A4B2 180538 - Image 1

Images are for illustrative purposes only. Please refer to data sheet for details.

SVX005A1-5A4B2 180538 EATON ELECTRIC Variable frequency drive

Reference: SVX005A1-5A4B2

Code: 180538

Manufacturer: EATON - MOELLER

Description:

Variable frequency drive
SVX FreqD 5,5kW 690V IP21 w/Br w/coat

Categories:

  • Low-voltage industrial components > Frequency converter less than 1 kV
  • EATON - MOELLER > Eaton Frequency Converters

Brand new product in its original packaging covered by the warranties and certifications provided by EATON - MOELLER

  • More Info
  • ETIM
  • PDF
  • Reviews
Guarantee, repair and return.

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

LAST VIEWED

MORE INFO

General specifications

Product Name
Eaton SVX Variable frequency drive
Catalog Number
180538
Model Code
SVX005A1-5A4B2
EAN
4015081757039
Product Length/Depth
558 mm
Product Height
237 mm
Product Width
195 mm
Product Weight
18.5 kg
Certifications
IEC/EN61800-5
RoHS, ISO 9001
UL Listed
RCM
CSA Class No.: 3211-06
UL Category Control No.: NMMS, NMMS2, NMMS7. NMMS8
UL File No.: E134360
UL report applies to both US and Canada
CSA-C22.2 No. 14
CE marking
UL 508C
DNV
IEC/EN 61800-2
IEC/EN 61800-3
Certified by UL for use in Canada
CUL
UL
CE
IEC/EN 61800-5-1

General

Communication interface
BACnet MS/TP, optional
LonWorks, optional
Modbus-TCP, optional
CANopen®, optional
PROFIBUS-DP
DeviceNet, optional
Ethernet IP, optional
Modbus-RTU, optional
EtherCAT, optional
PROFINET, optional
Connection to SmartWire-DT
No
Degree of protection
IP21
NEMA Other
Electromagnetic compatibility
1st and 2nd environments (according to EN 61800-3)
Environmental class
3C2, 3S2 (Air quality)
Fitted with:
OLED display
Internal DC link
IGBT inverter
Additional PCB protection
Brake chopper
Radio interference suppression filter
Frame size
FR6
Mounting position
Vertical
Product Category
Variable frequency drives
Protection
Finger and back-of-hand proof, Protection against direct contact (BGV A3, VBG4)
Radio interference class
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Suitable for
Branch circuits, (UL/CSA)

Climatic environmental conditions

Altitude
Max. 1000 m
Above 1000 m with 1 % performance reduction per 100 m
Max. 3000 m
Ambient operating temperature - min
-10 °C
Ambient operating temperature - max
50 °C
Ambient storage temperature - min
-40 °C
Ambient storage temperature - max
70 °C
Climatic proofing
< 95 % relative humidity, no condensation, no corrosion, no dripping water

Main circuit

Mains voltage - min
525 V
Mains voltage - max
690 V
Operating mode
Sensorless vector control (SLV)
U/f control
Output frequency - min
0 Hz
Output frequency - max
320 Hz
Output voltage (U2)
600 V AC, 3-phase
690 V AC, 3-phase
Rated control supply voltage
10 V DC (Us, max. 10 mA)
Rated frequency - min
45 Hz
Rated frequency - max
66 Hz
Rated operational current (Ie) at 110% overload
10 A
Rated operational current (Ie) at 150% overload
7.5 A
Rated operational power at 690 V, 50 Hz
5.5 kW
Rated operational power at 690 V, 50 Hz, 110% overload
7.5 kW
Rated operational voltage
690 V AC, 3-phase
600 V AC, 3-phase
Resolution
0.01 Hz (Frequency resolution, setpoint value)
Supply frequency
50/60 Hz
Switching frequency
1.5 kHz, 1 - 6 kHz adjustable, fPWM, Power section, Main circuit
System configuration type
AC supply systems with earthed center point
Voltage rating - max
690 V

Motor rating

Assigned motor current IM at 690 V, 50 Hz, 110% overload
8.8 A
Assigned motor current IM at 690 V, 60 Hz, 110% overload
8 A
Assigned motor current IM at 690 V, 60 Hz, 150% overload
5.3 A
Assigned motor power at 690 V, 60 Hz
5 HP
Assigned motor power at 690 V, 60 Hz, 110% overload
7.5 HP

Control circuit

Number of inputs (analog)
2 (parameterizable, 0 - 10 V DC, 0/4 - 20 mA)
Number of inputs (digital)
6 (parameterizable, max. 30 V DC)
Number of outputs (analog)
1
Number of outputs (digital)
1 (parameterizable, 48 V DC/50 mA)
Number of relay outputs
2 (parameterizable, N/O, 8 A (24 V DC) / 8 A (250 V AC) / 0,4 A (125 V DC))
Rated control voltage (Uc)
24 V DC (external, max. 250 mA)

Design verification

Equipment heat dissipation, current-dependent Pvid
138 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Rated operational current for specified heat dissipation (In)
7.5 A
Static heat dissipation, non-current-dependent Pvs
0 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

ETIM for 180538 Low-voltage industrial controls and switchgear (EC001857)

Feature nameMains voltage (EF006780)
Feature value525 V
Feature nameMains frequency (EF006783)
Feature value50/60 Hz
Feature nameMax. output frequency (EF007350)
Feature value320 Hz
Feature nameNumber of analogue outputs (EF001995)
Feature value1
Feature nameWith control element (EF001538)
Feature valueNo
Feature nameApplication in industrial area permitted (EF007294)
Feature valueNo
Feature nameApplication in domestic- and commercial area permitted (EF007295)
Feature valueNo
Feature nameSupporting protocol for TCP/IP (EF003050)
Feature valueNo
Feature nameSupporting protocol for PROFIBUS (EF003052)
Feature valueNo
Feature nameSupporting protocol for CAN (EF003053)
Feature valueNo
Feature nameSupporting protocol for INTERBUS (EF003054)
Feature valueNo
Feature nameSupporting protocol for ASI (EF003051)
Feature valueNo
Feature nameSupporting protocol for KNX (EF003055)
Feature valueNo
Feature nameSupporting protocol for Modbus (EF003057)
Feature valueNo
Feature nameSupporting protocol for Data-Highway (EF003058)
Feature valueNo
Feature nameSupporting protocol for DeviceNet (EF003059)
Feature valueNo
Feature nameSupporting protocol for SUCONET (EF003060)
Feature valueNo
Feature nameSupporting protocol for LON (EF003017)
Feature valueNo
Feature nameSupporting protocol for PROFINET IO (EF007525)
Feature valueNo
Feature nameSupporting protocol for PROFINET CBA (EF007524)
Feature valueNo
Feature nameSupporting protocol for SERCOS (EF006657)
Feature valueNo
Feature nameSupporting protocol for Foundation Fieldbus (EF007522)
Feature valueNo
Feature nameSupporting protocol for EtherNet/IP (EF007521)
Feature valueNo
Feature nameSupporting protocol for AS-Interface Safety at Work (EF007519)
Feature valueNo
Feature nameSupporting protocol for DeviceNet Safety (EF007520)
Feature valueNo
Feature nameSupporting protocol for INTERBUS-Safety (EF006662)
Feature valueNo
Feature nameSupporting protocol for PROFIsafe (EF007526)
Feature valueNo
Feature nameSupporting protocol for SafetyBUS p (EF007527)
Feature valueNo
Feature nameSupporting protocol for BACnet (EF011944)
Feature valueNo
Feature nameSupporting protocol for other bus systems (EF003062)
Feature valueNo
Feature nameWith optical interface (EF003028)
Feature valueNo
Feature nameWith PC connection (EF006107)
Feature valueNo
Feature nameIntegrated breaking resistance (EF007293)
Feature valueNo
Feature name4-quadrant operation possible (EF006803)
Feature valueNo
Feature nameType of converter (EF006978)
Feature valueOther
Feature nameDegree of protection (IP) (EF005474)
Feature valueIP21
Feature nameDegree of protection (NEMA) (EF011959)
Feature valueOther
Feature nameHeight (EF000040)
Feature value237 mm
Feature nameWidth (EF000008)
Feature value195 mm
Feature nameDepth (EF000049)
Feature value558 mm

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.