ELIWELL LKD41CO2XR400 LKD41CO2XR400 - Image 1

Images are for illustrative purposes only. Please refer to data sheet for details.

LKD41CO2XR400 ELIWELL LEAK DETECTOR LKD CO2 IP21 Electronic controls for automation

Reference: LKD41CO2XR400

Manufacturer: ELIWELL

Description:

LEAK DETECTOR LKD CO2 IP21 Electronic controls for automation
LKD 100 mod110 CO2 12/24V

Categories:

  • ELIWELL

Brand new product in its original packaging covered by the warranties and certifications provided by ELIWELL

  • More Info
  • PDF
  • Reviews
Guarantee, repair and return.

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

LAST VIEWED

MORE INFO

LKD LEAK DETECTORS



The gas sensors LKD represent
the current technology in gas detectors
and can detect the leakage of a large
range of gases (R134a, R404a, NH3,
R290, R600a and CO2).


The models available are:
Semiconductor (SC) and Infrared (ir).


Important feature of the sensors
LKD is that they can be used:


  • Alone (stand-alone), thanks to an output
    digital relay that can control a
    buzzer, a siren, etc
  • Integrated in the management system
    remote Eliwell (e.g. TelevisGo) or
    third parties thanks to a RS485 port
    on-board (only model Modbus).

SEMICONDUCTOR
R134a/R404a/NH3 - R290/R600a
INFRA-RED
CO2
PROTECTION IPIP41 (TN applications) — IP66 (applications BT)
DIMENSIONS/WEIGHT
  • IP41: 86x142x53 - 180 grams
  • IP66: 175x165x82 - 629 grams
POWER

12/24Vc/a ±20% 50/60 Hz

POWER CONSUMPTION (AT 12V)153mA136mA
ANALOG OUTPUTS0-5V, 1-5V, 0-10V, 2-10V, 4-20mA
DIGITAL OUTPUTS1 relay 1A/24Vc/a
BUZZERIf
DELAY ALARM SELECTABLE0, 1, 5, 10min
CONNECTIONS1 RS485 for connection to supervisor Modbus only in the corresponding model (see)
FIELD OF WORK TYPICALR134a: 0...1,000 ppm – R404a: 0...1,000 ppm
R290: 0...2,000 ppm – R600a: 0...2,000 ppm
NH3: 0...1,000 and 0...10,000 ppm
CO2 = 0...10,000 ppm
TEMPERATURE RANGEIP41: -20ºC ... +50 ° C — IP66: -40ºC ... +50ºC
HUMIDITY RANGE0 ... 95% (without condensation)
FAULT INDICATIONRed LED ON - green LED OFF
LIFE TIME OF THE SENSOR5-8 years8-10 years
ALARM THRESHOLD T5076 ppm25 ppm
ALARM THRESHOLD T90215 ppm90 ppm
RESETTING TIME600 sec.210 sec.

Characteristics

ReferenceLKD41CO2XR400
ModelLKD 110 CO2 12/24V. IP41
Relays1
GasR744-CO2
Degree IPIP41
Options GasR744-CO2
Supply voltage24 Vac/vdc, 12 Vac/vdc

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.