ELIWELL IDP29DB3S0000 IDP29DB3S0000 - Image 1

Images are for illustrative purposes only. Please refer to data sheet for details.

IDP29DB3S0000 ELIWELL IDPLUS 971 12V 2 PROBES, 2 RELAY (DEFROST OR VENT.) Electronic controls for automation

Reference: IDP29DB3S0000

Manufacturer: ELIWELL

Description:

IDPLUS 971 12V 2 PROBES, 2 RELAY (DEFROST OR VENT.) Electronic controls for automation

Categories:

  • ELIWELL

Brand new product in its original packaging covered by the warranties and certifications provided by ELIWELL

  • More Info
  • Reviews
Guarantee, repair and return.

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

LAST VIEWED

MORE INFO

CONTROLS FOR UNITS, STATIC, AIRY, OR HEAT



The family IDPLUS is especially suitable for stockists, since due to
yourversatility allows you to reduce the number of codescovering the maximum of possibilities.


Up to 4 different schedules of pre-configured parameters.


Parameter Cold/Heat.


Installation: on panel, with mounting hole 71x29mm (+0,2/-0,1 mm).


Usage temperature: -5...55°C.


Storage temperature: -30...85°C.


Type of probe range: PTC, NTC AND PT1000.


Simplified user interface.


List of parameters predefined
- selectable and rearmable.


Function HACCP.


Is connected to TelevisSystem and
ModBus.


New Unicard USB/TTL for upload/download of parameters.

Technical Datafor models IDPLUS 902 - 961 -971 -974 -978 (See corresponding tables)

IDPLUS902IDPLUS961IDPLUS971
Display field
  • probe NTC: -50,0...110,0°C
  • probe PTC: -55,0...140,0°C
  • probe Pt1000: -55,0...150,0°C
  • probe NTC: -50,0...110,0°C
  • probe PTC: -55,0...140,0°C
  • probe Pt1000: -55,0...150,0°C
  • probe NTC: -50,0...110,0°C
  • probe PTC: -55,0...140,0°C
  • probe Pt1000: -55,0...150,0°C
Displaywith decimal point * 3 digits + sign

with decimal point * 3 digits + sign

with decimal point * 3 digits + sign

Analog inputs1 PTC / NTC / Pt1000* 1 PTC / NTC / Pt1000* 2 PTC / NTC / Pt1000*
Configurable inputs1 digital (SELV) / analogue (PTC/NTC/Pt1000)*

1 digital (SELV) / analogue (PTC/NTC/Pt1000)*

1 digital (SELV) / analogue (PTC/NTC/Pt1000)*
1 digital (SELV) / serial TTL*
Connectivity

Port TTL for connection to Unicard/ Copy Card or to system monitoring TelevisSystem/ModBus* (need Bus Adapter)

Port TTL for connection to Unicard/ Copy Card or to system monitoring TelevisSystem/ModBus* (need Bus Adapter)

Port TTL for connection to Unicard/ Copy Card or to system monitoring TelevisSystem/ModBus* (need Bus Adapter)

Digital outputs
  • N. A. 8(4)A - N. C. 6(3)A max 250V~
  • 1 SPST 2Hp 12(12)A 250V~ N. A.
  • 1 SPDT ½Hp 8(4)A 250V~ N. A.
  • 1 SPST 2Hp 12(12)A 250V~
Field measurement

-55,0...150,0°C

-55,0...150,0°C

-55,0...150,0°C

Consumption4.5 W max4.5 W max4.5 W max
Power
  • 230V~ ±10% 50/60Hz
  • 12V~/c ▒ 10% 50/60Hz
  • 230V~ ±10% 50/60Hz
  • 12V~/c ▒ 10% 50/60Hz
  • 230V~ ±10% 50/60Hz
  • 12V~/c ▒ 10% 50/60Hz
Dimensions74 x 32 x 59 mm74 x 32 x 59 mm74 x 32 x 59 mm
HACCPpresentpresentpresent
* selectable by parameter

IDPLUS974IDPLUS978
Display field
  • probe NTC: -50,0...110,0°C
  • probe PTC: -55,0...140,0°C
  • probe Pt1000: -55,0...150,0°C
  • probe NTC: -50,0...110,0°C
  • probe PTC: -55,0...140,0°C
  • probe Pt1000: -55,0...150,0°C
Display

with decimal point * 3 digits + sign

with decimal point * 3 digits + sign

Analog inputs2 PTC / NTC / Pt1000* 2 PTC / NTC / Pt1000*
Configurable inputs

1 digital (SELV) / analogue (PTC/NTC/Pt1000)*
1 digital (SELV) / serial TTL*

1 digital (SELV) / analogue (PTC/NTC/Pt1000)*
1 digital (SELV) / serial TTL*
Connectivity

Port TTL for connection to Unicard/ Copy Card or to system monitoring TelevisSystem/ModBus* (need Bus Adapter)

Port TTL for connection to Unicard/ Copy Card or to system monitoring TelevisSystem/ModBus* (need Bus Adapter)

Digital outputs
  • 1 SPDT ½Hp 8(4)A 250V~ N. A.
  • 1 SPST 2Hp 12(12)A 250V~
  • 1 SPST 5(2)A 250V~
  • 1 SPDT ½Hp 8(4)A 250V~ N. A.
  • 1 SPST 5Hp 12(12)A 250V~
  • 1 SPST 1.5 HP 10(6)A 250V~
  • 1 SPST 5(2)A 250V~
Field measurement

-55,0...150,0°C

-55,0...150,0°C

Consumption3W max3W max
Power
  • 230V~ ±10% 50/60Hz
  • 12V~/c ▒ 10% 50/60Hz
  • 230V~ ±10% 50/60Hz
  • 12V~/c ▒ 10% 50/60Hz
Dimensions74 x 32 x 59 mm74 x 32 x 59 mm
HACCPpresentpresent
* selectable by parameter

Characteristics

ReferenceIDP29DB3S0000
ModelIDPLUS 971
Relays2
USB UnicardIf
Copy CardIf
Individual PackingIf
HACCPIf
D. IIf
Probes2 NTC, PTC, PT1000
Digital InputIf
FormatPanel 74x32
Supply voltage12 Vac/vdc

DATASHEET - PDF

Title
Size
Type

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.