NZM4-XUV 266588 0004358959 EATON ELECTRIC Undervoltage release, for delay unit View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

NZM4-XUV 266588 0004358959 EATON ELECTRIC Undervoltage release, for delay unit

NZM4-XUV

266588

0004358959

EATON-MOELLER

Undervoltage release, for delay unit

NZM4-XUV

More details


Low-voltage industrial components > Under voltage coil

Circuit Breakers NZM Accessories

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total price: $146.67
Unit price: $146.67

Quantity Price
1+$146.67
2+$133.21
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Undervoltage release, for delay unit
Undervoltage release for switch frame size NZM4, for combination with separate delay unit

General specifications
Product name
Eaton Moeller series NZM release
Part no.
NZM4-XUV
EAN
4015082665883
Product Length/Depth
107 millimetre
Product height
51 millimetre
Product width
64 millimetre
Product weight
0.263 kilogram
Compliances
IEC
RoHS conform
Certifications
CSA certified
UL listed
CE marking
CSA (Class No. 1437-01)
UL (File No. E140305)
IEC60947
UL (Category Control Number DIHS)
CSA (File No. 22086)
CSA-C22.2 No. 5-09
UL489
Product Tradename
NZM
Product Type
Accessories
Product Sub Type
Release
Delivery program
Type
AccessoryUndervoltage releaseUndervoltage release, off-delayed
Special features
Special releases for combining with separate delay time.For use with emergency-stop devices in connection with an emergency-stop button.not UL/CSA approvedUVU-NZM delay unit is additionally required.Cannot be installed simultaneously with separate NZM...-XHIV early-make auxiliary contact or NZM...-XA... shunt release.
Frame
NZM4
Suitable for
Off-load switch
Used with
NZM4(-4)
N(S)4(-4)
Technical Data - Electrical
Voltage type
DC
Voltage rating at DC
18 V DC
Rated control supply voltage (Us) at AC, 50 Hz - min
0 V
Rated control supply voltage (Us) at AC, 50 Hz - max
0 V
Rated control supply voltage (Us) at AC, 60 Hz - min
0 V
Rated control supply voltage (Us) at AC, 60 Hz - max
0 V
Rated control supply voltage (Us) at DC - min
0 V
Rated control supply voltage (Us) at DC - max
0 V
Electric connection type
Screw connection
Technical Data - Mechanical
Number of contacts (change-over contacts)
0
Number of contacts (normally closed contacts)
0
Number of contacts (normally open contacts)
0
Connection type
With bolt connection
Special features
Special releases for combining with separate delay time.For use with emergency-stop devices in connection with an emergency-stop button.not UL/CSA approvedUVU-NZM delay unit is additionally required.Cannot be installed simultaneously with separate NZM...-XHIV early-make auxiliary contact or NZM...-XA... shunt release.
Technical Data - Mechanical - Terminals
Terminal capacity (solid/flexible conductor)
18 - 14 AWG (1x) at shunt release
18 - 14 AWG (2x) at shunt release
0.75 mm² - 2.5 mm² (2x) for undervoltage releases, off-delayed with ferrule
18 - 14 AWG (1x) for undervoltage releases, off-delayed
0.75 mm² - 2.5 mm² (1x) at shunt release with ferrule
0.75 mm² - 2.5 mm² (2x) at shunt release with ferrule
0.75 mm² - 2.5 mm² (1x) for undervoltage releases, off-delayed with ferrule
18 - 14 AWG (2x) for undervoltage releases, off-delayed
Design verification as per IEC/EN 61439
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Additional information
Functions
Delayed

Technical data ETIM 9.0

Low-voltage industrial components (EG000017) / Under voltage coil (EC001022)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Circuit breaker (LV < 1 kV) / Undervoltage trip (ecl@ss13-27-37-04-17 [AKF015018])
Rated control supply voltage AC 50 Hz
0 - 0 V
Rated control supply voltage AC 60 Hz
0 - 0 V
Rated control supply voltage DC
0 - 0 V
Voltage type for actuating
DC
Type of electric connection
Screw connection
Number of contacts as normally open contact
0
Number of contacts as normally closed contact
0
Number of contacts as change-over contact
0
Delayed
Yes
Suitable for power circuit breaker
No
Suitable for off-load switch
Yes
Suitable for motor safety switch
No
Suitable for overload relay
No

Datasheet - PDF

Title: Size: Type:
NZM4-XUV 0004358959 266588 EN_266588.pdf 114 Kbytes   NZM4-XUV 0004358959 266588 EN_266588.pdf

Reviews (1)

  • R Omar
    Customer rating:
  • Page:1
    Add Review
    hide form
    Rating:
    Name:
    Email:
    Subject:
    Text:
      Captcha
      Add review

    All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.