EATON - MOELLER DTZ0,1(*/*)* 914799 Y7-914799 - Image 1

Images are for illustrative purposes only. Please refer to data sheet for details.

DTZ0,1(*/*)* 914799 Y7-914799 EATON ELECTRIC Three-phase control/isolation/safety transformer, 100VA, non-st..

Reference: DTZ0,1(*/*)*

Code: 914799

Catalog Number: Y7-914799

Manufacturer: EATON - MOELLER

Description:

Three-phase control/isolation/safety transformer, 100VA, non-standard voltage
DTZ0,1(*/*)*
Eaton Moeller® series DTZ Three-phase control isolating safety transformer, 0.1 kVA, Rated input voltage 50 – 950 ± 5 % V, Rated output voltage 18.5 – 1000 V
Three-phase control transformer performed according to VDE 0550, VDE 0550 part1, IEC/EN 61558-2-2, VDE0570 part 2-2 as safety transformer VDE 0570 part 2-6 and as isolating transformer VDE 0570 part 2-4, UL 506, CSA 22.2 No.66, OVE. Rated input voltage selectable of 50-950V +-5%, rated output voltage can be selected from 18.5 - 1000 rated power 0.1 kVA (*/*) = wildcard for rated input voltage / rated output voltage

Categories:

  • Low-voltage industrial components > Three-phase control transformer
  • EATON - MOELLER > Transformers

Brand new product in its original packaging covered by the warranties and certifications provided by EATON - MOELLER

  • More Info
  • ETIM
  • PDF
  • Reviews
Guarantee, repair and return.

* This article is restricted. Please ask us for a quotation and we will check if there are units available or we will offer you an alternative product.

Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

LAST VIEWED

MORE INFO

General specifications

Product Name
Eaton Moeller® series DTZ Control transformer
Catalog Number
914799
Model Code
DTZ0,1(*/*)*
Product Length/Depth
65 mm
Product Height
134 mm
Product Width
125 mm
Product Weight
1.9 kg
Certifications
CSA-C22.2 No. 66
UL5085-1
CSA-C22.2 No. 66.1-06
UL File No.: E167225
CE
UL report applies to both US and Canada
IEC/EN 61558-2-2
UL Category Control No.: XPTQ2, XPTQ8
CSA-C22.2 No. 66.2-06
UL Recognized
Certified by UL for use in Canada
UL 5085-2
UL 506

General

Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
40 °C
Product category
Three-phase DTZ control transformers
Suitable for
Branch circuits, (UL/CSA)

Electrical rating

Rated power
100 VA
Relative short-circuit voltage
15 %
Short-time rating
0.2 kVA
Voltage rating - max
600 V

Design verification

Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Rated operational current for specified heat dissipation (In)
0 A
Static heat dissipation, non-current-dependent Pvs
33 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

ETIM for 914799 Low-voltage industrial controls and switchgear (EC002485)

Feature nameBuilt as safety transformer (EF007235)
Feature valueYes
Feature nameBuilt as isolating transformer (EF007238)
Feature valueYes
Feature nameBuilt as energy saving transformer (EF007005)
Feature valueNo
Feature namePrimary voltage 1 (EF006125)
Feature value50 V
Feature namePrimary voltage 2 (EF006126)
Feature value50 V
Feature namePrimary voltage 3 (EF006127)
Feature value50 V
Feature namePrimary voltage 4 (EF007410)
Feature value50 V
Feature namePrimary voltage 5 (EF007411)
Feature value50 V
Feature namePrimary voltage 6 (EF007412)
Feature value50 V
Feature namePrimary voltage 7 (EF007413)
Feature value0 V
Feature namePrimary voltage 8 (EF007414)
Feature value0 V
Feature namePrimary voltage 9 (EF007415)
Feature value0 V
Feature namePrimary voltage 10 (EF007409)
Feature value0 V
Feature nameSecondary voltage 1 (EF007472)
Feature value18.5 V
Feature nameSecondary voltage 2 (EF007474)
Feature value18.5 V
Feature nameSecondary voltage 3 (EF007475)
Feature value18.5 V
Feature nameSecondary voltage 4 (EF007476)
Feature value18.5 V
Feature nameSecondary voltage 5 (EF007477)
Feature value18.5 V
Feature nameSecondary voltage 6 (EF007478)
Feature value18.5 V
Feature nameSecondary voltage 7 (EF007479)
Feature value0 V
Feature nameSecondary voltage 8 (EF007480)
Feature value0 V
Feature nameSecondary voltage 9 (EF007481)
Feature value0 V
Feature nameSecondary voltage 10 (EF007473)
Feature value0 V
Feature nameWiring system (EF002960)
Feature valueOther
Feature nameRated power (EF007051)
Feature value100 VA
Feature nameType of insulation material according to IEC 85 (EF007299)
Feature valueB
Feature nameShort-circuit-proof (EF007332)
Feature valueNo
Feature nameRelative short circuit voltage (EF007452)
Feature value15 %
Feature nameConductor material (EF001622)
Feature valueCopper
Feature nameWidth (EF000008)
Feature value125 mm
Feature nameHeight (EF000040)
Feature value134 mm
Feature nameDepth (EF000049)
Feature value65 mm
Feature nameDegree of protection (IP) (EF005474)
Feature valueIP00
Feature nameDegree of protection (NEMA) (EF011959)
Feature valueOther

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.