T0-1-15110/E 009172 EATON MOELLER Series switches, Contacts: 2, 20 A, front plate: 0-1-2-3, 90 °, maintained.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

T0-1-15110/E 009172 EATON MOELLER Series switches, Contacts: 2, 20 A, front plate: 0-1-2-3, 90 °, maintained..

T0-1-15110/E

009172

EATON-MOELLER

Available Ship on today

Series switches, Contacts: 2, 20 A, front plate: 0-1-2-3, 90 °, maintained, flush mounting

More details


* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total price: $33.43
Unit price: $33.43

Quantity Price
1+$33.43
6+$29.73
11+$28.93
16+$28.52
22+$28.21
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Delivery program
Product range
Control switches
Part group reference
T0
Basic function
Series switches
with black thumb grip and front plate
Contacts
2
Degree of Protection
Front IP65
Design
flush mounting
Contact sequence
Switching angle
° 90
Switching performance
maintained
With 0 (Off) position
Front plate no.
front plate
0-1-2-3
Motor rating AC-23A, 50 - 60 Hz
400 V
PkW 5.5
Rated uninterrupted current
IuA 20
Note on rated uninterrupted current !u
Rated uninterrupted current Iu is specified for max. cross-section.
Number of contact units
contact unit(s) 1
Technical data
General
Standards
IEC/EN 60947, VDE 0660, IEC/EN 60204, CSA, UL
Switch-disconnector according to IEC/EN 60947-3
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperature
Open
°C -25 - +50
Enclosed
°C -25 - +40
Overvoltage category/pollution degree
III/3
Rated impulse withstand voltage
UimpV AC 6000
Mechanical shock resistance
g 15
Mounting position
As required
Contacts
Electrical characteristics
Rated operational voltage
UeV AC 690
Rated uninterrupted current
IuA 20
Note on rated uninterrupted current !u
Rated uninterrupted current Iu is specified for max. cross-section.
Load rating with intermittent operation, class 12
AB 25 % DF
x Ie 2
AB 40 % DF
x Ie 1.6
AB 60 % DF
x Ie 1.3
Short-circuit rating
Fuse
A gG/gL 20
Rated short-time withstand current (1 s current)
IcwArms 320
Note on rated short-time withstand current lcw
Current for a time of 1 second
Rated conditional short-circuit current
IqkA 6
Switching capacity
cos ϕ rated making capacity as per IEC 60947-3
A 130
Rated breaking capacity cos ϕ to IEC 60947-3
A
230 V
A 100
400/415 V
A 110
500 V
A 80
690 V
A 60
Safe isolation to EN 61140
between the contacts
V AC 440
Current heat loss per contact at Ie
W 0.6
Current heat loss per auxiliary circuit at Ie (AC-15/230 V)
CO 0.6
Lifespan, mechanical
Operationsx 106 > 0.4
Maximum operating frequency
Operations/h 1200
AC
AC-3
Rating, motor load switch
PkW
220 V 230 V
PkW 3
230 V Star-delta
PkW 5.5
400 V 415 V
PkW 5.5
400 V Star-delta
PkW 7.5
500 V
PkW 5.5
500 V Star-delta
PkW 7.5
690 V
PkW 4
690 V Star-delta
PkW 5.5
Rated operational current motor load switch
230 V
IeA 11.5
230 V star-delta
IeA 20
400V 415 V
IeA 11.5
400 V star-delta
IeA 20
500 V
IeA 9
500 V star-delta
IeA 15.6
690 V
IeA 4.9
690 V star-delta
IeA 8.5
AC-21A
Rated operational current switch
440 V
IeA 20
AC-23A
Motor rating AC-23A, 50 - 60 Hz
PkW
230 V
PkW 3
400 V 415 V
PkW 5.5
500 V
PkW 7.5
690 V
PkW 5.5
Rated operational current motor load switch
230 V
IeA 13.3
400 V 415 V
IeA 13.3
500 V
IeA 13.3
690 V
IeA 7.6
DC
DC-1, Load-break switches L/R = 1 ms
Rated operational current
IeA 10
Voltage per contact pair in series
V 60
DC-21A
IeA
Rated operational current
IeA 1
Contacts
Quantity 1
DC-23A, motor load switchL/R = 15 ms
24 V
Rated operational current
IeA 10
Contacts
Quantity 1
48 V
Rated operational current
IeA 10
Contacts
Quantity 2
60 V
Rated operational current
IeA 10
Contacts
Quantity 3
120 V
Rated operational current
IeA 5
Contacts
Quantity 3
240 V
Rated operational current
IeA 5
Contacts
Quantity 5
DC-13, Control switches L/R = 50 ms
Rated operational current
IeA 10
Voltage per contact pair in series
V 32
Control circuit reliability at 24 V DC, 10 mA
Fault probabilityHF < 10 -5, < 1 fault in 100000 operations
Terminal capacities
Solid or stranded
mm2 1 x (1 - 2,5)
2 x (1 - 2,5)
Flexible with ferrules to DIN 46228
mm2 1 x (0.75 - 2.5)
2 x (0.75 - 2.5)
Terminal screw
M3.5
Tightening torque for terminal screw
Nm 1
Technical safety parameters:
Notes
B10d values as per EN ISO 13849-1, table C1
Rating data for approved types
Contacts
Rated operational voltage
UeV AC 600
Rated uninterrupted current max.
Main conducting paths
General use
A 16
Auxiliary contacts
General Use
IUA 10
Pilot Duty
A 600
P 600
Switching capacity
Maximum motor rating
Single-phase
120 V AC
HP 0.5
200 V AC
HP 1
240 V AC
HP 1.5
Three-phase
200 V AC
HP 3
240 V AC
HP 3
480 V AC
HP 7.5
600 V AC
HP 7.5
Short Circuit Current Rating
SCCR
Basic Rating
kA 5
max. Fuse
A 50
High fault rating
kA 10
max. Fuse
A 20, Class J
Terminal capacity
Solid or flexible conductor with ferrule
AWG 18 - 14
Terminal screw
M3.5
Tightening torque
lb-in 8.8
Approvals
Product Standards UL 60947-4-1;CSA - C22.2 No. 60947-4-1-14; CSA-C22.2 No. 94; IEC/EN 60947-3; CE marking
UL File No. E36332
UL Category Control No. NLRV
CSA File No. 12528
CSA Class No. 3211-05
North America Certification UL listed, CSA certified
Suitable for Branch circuits, suitable as motor disconnect
Degree of Protection IEC: IP65; UL/CSA Type 1, 12
Technical data ETIM 7.0(Show features)(Hide features)
Low-voltage industrial components (EG000017) / Off-load switch (EC001105)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Off-load switch, circuit breaker, control switch / Changeover switch ([email protected] [AKF062013])
Model
Reverser
Number of poles
1
With 0 (off) position
Yes
With retraction in 0-position
No
Rated permanent current Iu
A 20
Rated operation current Ie at AC-3, 400 V
A 11.5
Rated operation power at AC-3, 400 V
kW 4
Degree of protection (IP), front side
IP65
Degree of protection (NEMA), front side
12
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Suitable for ground mounting
No
Suitable for front mounting 4-hole
Yes
Suitable for distribution board installation
No
Suitable for intermediate mounting
No
Complete device in housing
No
Material housing
Plastic
Type of control element
Toggle
Type of electrical connection of main circuit
Screw connection

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Últimas Opiniones de Nuestros Clientes

Todas las valoraciones que recibimos de los artículos que ofrecemos son reales y están verificadas. Un pequeño gesto, pero de mucho valor. Por eso, te agradecemos ese minuto que inviertes en dejarnos tu opinión y calificación sobre los productos, porque nos ayuda a seguir mejorando y a ofrecerte un servicio de todavía mayor calidad.