IN32B4-08F 124076 EATON ELECTRIC Break switch, 4P, 800A, fixed

IN32B4-08F

124076

EATON-MOELLER

Break switch, 4P, 800A, fixed

More details


Home > EATON - MOELLER

Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Delivery programme
Product range
Air circuit-breakers/switch-disconnectors
Product range
Open switch-disconnectors
Current Range
over 4000 A
Protective function
Switch disconnector
Installation type
Fixed
Construction size
IN32
Release system
Electronic release
Standard/Approval
IEC
Number of poles
4 pole
Degree of Protection
IP20, IP55 with protective cover
Rated current = rated uninterrupted current
In= Iu A 800
Making capacity Icm to 440 V 50/60 Hz
Icm kA 55
t = 1 s
Icw kA 65
Notes

Including rear connection main terminals and secondary terminal blocks according to ordered breaker options.

Technical data
General
Standards
IEC/EN 60947
Ambient temperature
Storage
ϑ °C -40 - +70
Operating (open)
°C -25 - +70
Mounting position
>>
Utilization category
B
Degree of Protection
IP20, IP55 with protective cover
Direction of incoming supply
as required
Main conducting paths
Rated current = rated uninterrupted current
In= Iu A 800
Rated uninterrupted current at 50 °C
Iu A 800
Rated uninterrupted current at 60 °C
Iu A 800
Rated uninterrupted current at 70 °C
Iu A 800
Rated impulse withstand voltage
Uimp V AC 8000
Rated operational voltage
Ue V AC 690
Use in IT electrical power networks up to U = 440 V
IIT kA 13
Overvoltage category/pollution degree
III/3
Rated insulation voltage
Ui V 1000
Switching capacity
Rated short-circuit making capacity
Icm
up to 440 V 50/60 Hz
Icm kA 55
up to 690 V 50/60 Hz
Icm kA 143
Rated short-time withstand current 50/60 Hz
t = 1 s
Icw kA 65
Operating times
Closing delay via spring release
ms 35
Break times
ms 40
Total opening delay via shunt release
ms 30
Total opening delay via undervoltage release
ms 35/70
Maximum operating frequency
Ops./h
Maximum operating frequency
Operations/h 60
Heat dissipation at rated current In
Fixed mounting
W 40
Withdrawable units (switch with cassette)
W 85
Weight
Fixed mounting
3-pole
kg 58
4-pole
kg 72
Withdrawable
3-pole
kg 70
4-pole
kg 88
Cassette
3 pole
kg 34
4 pole
kg 38
Terminal capacities
Copper bar
Fixed mounting
Black
mm 2 x 5 x 50
Withdrawable units
Black
mm 2 x 5 x 50


Permissible continuous current for circuit‐breakers operating in switchboards at various internal ambient temperatures. The switchboard’s internal ambient temperature should be estimated using the calculation methods of IEC regulation.

Design verification as per IEC/EN 61439(Show features)(Hide features)
Technical data for design verification
Operating ambient temperature min.
°C -25
Operating ambient temperature max.
°C 70
Dimensions
>

Datasheet - PDF

Title: Size: Type:
PDF CATALOGUE EATON EN .pdf 38 Mbytes
IN32B4-08F 124076 124076_EN.pdf 225 Kbytes   IN32B4-08F  124076 124076_EN.pdf

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.