Eaton Moeller® series M22 Surface mounting enclosure, 2 mounting locations
Surface mounting enclosure, Housing: Insulated material, With high-grade steel screws, Number of locations: 2, Cable entry: rear: 2 x M20, at top: 1 x M20, lateral: 2 x M20/M25 (1 x each side), Degree of Protection: IP66, IP67, IP69K, Color RAL Value: RAL 7035, Color: Enclosure base anthracite, Connection to SmartWire-DT: no, For use with: (Illuminated) pushbuttons, (Illuminated) selector switches, Key-operated pushbuttons, Indicator light, controlled stop/emergency-stop buttons with yellow label
Low-voltage industrial components > Enclosure for control circuit devices
Auxiliary Control and Signalling Elements
Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER
| Product Name | Eaton Moeller® series M22 surface mounting enclosure |
| Catalog Number | 216537 |
| Model Code | M22-I2 |
| EAN | 4015082165376 |
| Product Length/Depth | 80 mm |
| Product Height | 56 mm |
| Product Width | 120 mm |
| Product Weight | 0.197 kg |
| Certifications | UL 508 CSA File No.: 012528 CSA CE UL Category Control No.: NKCR CSA-C22.2 No. 94-91 IEC/EN 60947-5 UL UL File No.: E29184 CSA Class No.: 3211-03 CSA-C22.2 No. 14-05 |
| 10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
| 10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
| 10.2.2 Corrosion resistance | Meets the product standard's requirements. |
| 10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. |
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. |
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | Meets the product standard's requirements. |
| 10.2.4 Resistance to ultra-violet (UV) radiation | Please enquire |
| 10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.7 Inscriptions | Meets the product standard's requirements. |
| 10.3 Degree of protection of assemblies | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.4 Clearances and creepage distances | Meets the product standard's requirements. |
| 10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. |
| 10.8 Connections for external conductors | Is the panel builder's responsibility. |
| 10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
| 10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
| 10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. |
| Fitted with: | High-grade steel screws |
| Connection to SmartWire-DT | No |
| Enclosure material | Plastic |
| Enclosure type | Surface mounting housing |
| Ambient operating temperature - max | 70 °C |
| Ambient operating temperature - min | -25 °C |
| Force for positive opening - min | 0 N |
| Number of command positions | 2 |
| Number of locations | 2 |
| Enclosure color | Gray |
| Material quality | Other |
| Opening diameter | 22.5 mm |
| RAL-number | 7035 |
| Degree of protection | IP67/IP69K NEMA 4X |
| Knockouts | 1 x M20 (cable entry knockout at the top) 2 x M20/25 (cable entry knockout at the side, 1 x each side) 2 x M20 (cable entry knockouts at the rear) |
| Feature Name | Feature Value |
|---|---|
| Number of command positions (EF001372) | 2 |
| Construction type housing (EF004008) | Surface mounting housing |
| Housing material (EF001596) | Plastic |
| Housing material quality (EF024143) | Other |
| Diameter openings (EF000243) | 22.5 mm |
| Colour housing cover (EF001373) | Grey |
| Degree of protection (IP) (EF005474) | IP67/IP69K |
| Degree of protection (NEMA) (EF011959) | 4X |
| Width (EF000008) | 120 mm |
| Height (EF000040) | 56 mm |
| Depth (EF000049) | 80 mm |
| Title: | Size: | Type: |
|---|---|---|
| PDF EATON COMMAND INDICATION EN.pdf | 24 Mbytes |
|
| PDF CATALOGUE EATON EN .pdf | 38 Mbytes |
|
| M22-I2 Y7-216537 216537 DE_216523.pdf | 1 Mbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.