SWD4-SF8-20 116031 EATON ELECTRIC Housing bushing socket, SmartWire-DT, socket, M20, for SWD4-SM8 plugs for .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

SWD4-SF8-20 116031 EATON ELECTRIC Housing bushing socket, SmartWire-DT, socket, M20, for SWD4-SM8 plugs for ..

SWD4-SF8-20

116031

EATON-MOELLER

Housing bushing socket, SmartWire-DT, socket, M20, for SWD4-SM8 plugs for round cable

More details


PLC's > Accessories/spare parts for controls

Smartwire Darwin

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Housing bushing socket, SmartWire-DT, socket, M20, for SWD4-SM8 plugs for round cable
Enclosure bushing for flush mounting in surface mounting enclosure M22-I…, 8 pole socket for connection to SWD4-SM8-67(W), enclosure degree of protection IP67 8 prefabricated cables for connection to card M22-SWD-I...

Delivery program

Basic function accessories
Housing bushing socket
Product range
SmartWire-DT accessories
Degree of Protection
IP20
Length
0.15 m
For use with
M22-SWD…

Technical data

General
Standards
IEC/EN 61131-2
EN 50178
Dimensions (W x H x D)
24 x 26 x 162 mm
Weight
0.02 kg
Mounting position
As required
Note on heat dissipation
not relevant
Ambient conditions, mechanical
Protection type (IEC/EN 60529, EN50178, VBG 4)
IP20
Climatic environmental conditions
Climatic proofing
Dry heat to IEC 60068-2-2
Damp heat as per EN 60068-2-3
Air pressure (operation)
795 - 1080 hPa
Ambient temperatureOperation [ϑ]
-25 - +55 °C
Ambient temperatureStorage / Transport [ϑ]
-40 - +70 °C
Ambient temperatureRelative humidityCondensation
Take appropriate measures to prevent condensation
Ambient temperatureRelative humidityRelative humidity, non-condensing (IEC/EN 60068-2-30)
5 - 95 %
Connection options
Connection 1
SWD-IN: 8 cables
Connection 2
M20 socket, 8 pole
Number of insertion cycles
≥ 500

Design verification as per IEC/EN 61439

Technical data for design verification
Rated operational current for specified heat dissipation [In]
0 A
Heat dissipation per pole, current-dependent [Pvid]
0 W
Equipment heat dissipation, current-dependent [Pvid]
0 W
Static heat dissipation, non-current-dependent [Pvs]
0 W
Heat dissipation capacity [Pdiss]
0 W
Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+55 °C
Degree of Protection
IP20
IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Meets the product standard's requirements.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 7.0

PLC's (EG000024) / Accessories for controls (EC002584)
Electric engineering, automation, process control engineering / Control / Programmable logic control (SPS) / Programmable logic control (SPS, accessories) ([email protected] [AFR333003])
Type of electrical accessory
Plug
Type of mechanical accessory
Other

Approvals

UL File No.
E29184
UL Category Control No.
NKCR
CSA File No.
2324643
CSA Class No.
3211-07
North America Certification
UL listed, CSA certified
Specially designed for North America
No

Dimensions

2723DIM-14
Housing bushing socket

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.