Product name
Eaton Moeller series NZM connection type
Product Length/Depth
54 millimetre
Product height
10 millimetre
Product width
129 millimetre
Product weight
0.639 kilogram
Compliances
IEC
UL/CSA
RoHS conform
Certifications
CSA-C22.2 No. 5-09
UL (File No. E31593)
CSA (Class No. 1432-01)
IEC60947
UL489
UL (Category Control Number DIHS)
CSA certified
CE marking
UL listed
CSA (File No. 22086)
Product Sub Type
Connection type
Type
AccessoryModule plateTerminal
Number of poles
Three-pole
Special features
Two holes
Suitable for
Copper cable lugs
Three-pole
Technical Data - Mechanical
Special features
Two holes
Technical Data - Mechanical - Terminals
Terminal capacity (flexible cable)
35 mm² - 185 mm² (4x)
Max. 350 AWG/kcmil (2x)
2 - 350 AWG/kcmil (4x)
95 mm² - 185 mm² (2x)
Terminal capacity (copper busbar)
50 mm x 10 mm (2x)
Terminal capacity (copper strip)
10 segments of 50 mm x 1 mm (2x)
Design verification as per IEC/EN 61439
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.