ANUNCIAR
NZM4-XKM2 266820 Y7-266820 EATON ELECTRIC Module plate 2-hole 3p, size 4 View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

NZM4-XKM2 266820 Y7-266820 EATON ELECTRIC Module plate 2-hole 3p, size 4

NZM4-XKM2

266820

Y7-266820

EATON-MOELLER

Module plate 2-hole 3p, size 4

NZM4-XKM2

Eaton Moeller series NZM - Molded Case Circuit Breaker. Module plate 2-hole 3p, size 4

Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: part no. contains parts for a terminal located at top or bottom for 3 or 4 pole switches. For M10 screws. Can be enlarged for M12 screws. Use special cable lug narrow version. Can be fitted to circuit-breaker with screw connection. insulation using NZM4(-4)-XKSA cover or NZM4(-4)-XKP phase isolator necessary. Can be used for: NZM4, N(S)4

More details


Low-voltage industrial components > Connection vane/phase spreader

Circuit Breakers NZM

Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total: $162.69
Unit price: $162.69
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



General specifications

Product Name
Eaton Moeller series NZM connection type
Catalog Number
266820
Model Code
NZM4-XKM2
EAN
4015082668204
Product Length/Depth
54 mm
Product Height
10 mm
Product Width
129 mm
Product Weight
0.639 kg
Compliances
UL/CSA
IEC
RoHS conform
Certifications
UL489
CE marking
UL listed
UL (File No. E31593)
CSA (File No. 22086)
UL (Category Control Number DIHS)
IEC60947
CSA certified
CSA-C22.2 No. 5-09
CSA (Class No. 1432-01)

Product specifications

Type
AccessoryModule plateTerminal
Special features
Two holes
Amperage Rating
≦ 1400 A
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
Frame
NZM4
Used with
NZM4, N(S)4
Suitable for
Copper cable lugs
Three-pole
Number of poles
Three-pole
Terminal capacity (copper strip)
10 segments of 50 mm x 1 mm (2x)
Terminal capacity (flexible cable)
35 mm² - 185 mm² (4x)
Max. 350 AWG/kcmil (2x)
2 - 350 AWG/kcmil (4x)
95 mm² - 185 mm² (2x)
Terminal capacity (copper busbar)
50 mm x 10 mm (2x)

ETIM for 266820 Low-voltage industrial controls and switchgear (EC002019)
Feature Name Feature Value
Suitable for number of poles (EF001589) 3

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.