NZM2/3-XMVRL 104549 EATON ELECTRIC Interlock, mechanical, for remote operator View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

NZM2/3-XMVRL 104549 EATON ELECTRIC Interlock, mechanical, for remote operator

NZM2/3-XMVRL

104549

EATON-MOELLER

Interlock, mechanical, for remote operator

NZM2/3-XMVRL

More details


Low-voltage industrial components > Mechanic interlock for switch

Circuit Breakers NZM Accessories

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total price: $448.79
Unit price: $448.79

Quantity Price
1+$448.79
2+$448.80
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Interlock, mechanical, for remote operator
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: for 2 switches of the same or different type with opposed operation. Extra long Bowden cable for mounting one above the other or in adjacent enclosures. Type contains parts for 2 switches. Remote operator additionally required. Cannot be combined with rotary handles, door coupling rotary handles and early-make auxiliary contacts as well as direct-switching remote operator NZM2-XRD. Can be used for: NZM2(-4), N(N/O)2(-4), +NZM3(-4), N(N/O)3(-4)

Delivery program

Description
For 2 switches of the same or next frame size with each other
Extra long Bowden cables for mounting under one another or in adjacent control panel sections
For use with
NZM2(-4), N(S)2(-4)
+ NZM3(-4), N(S)3(-4)
Notes

Type contains parts for both switch sides.

Extension shaft additionally required.

Max. switch clearances Engineering

Can not be combined with rotary handles, door coupling rotary handles, early-make auxiliary contacts, and direct-switching remote operator NZM2-XRD.

Design verification as per IEC/EN 61439

IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 7.0

Low-voltage industrial components (EG000017) / Mechanic interlock for switch (EC001044)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Component for low-voltage switching technology / Mechanic interlock for switch ([email protected] [AKN341013])
Auxiliary contacts, extendable
No
Number of contacts as normally closed contact
0
Number of contacts as normally open contact
0

Dimensions

1230DRW-74

Datasheet - PDF

Title: Size: Type:
NZM2/3-XMVRL 104549 EN_104549.pdf 216 Kbytes   NZM2/3-XMVRL  104549 EN_104549.pdf

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.