NZM-XDMI612

Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: inclusive NZM-XDMI-CAB connection cable between NZM and DMI (length: 2 m). Query from diagnostics and operational data. Recording of current values, motor starter function, parameter assignment. Control of the circuit-breakers with electronic trip block. Comprehensive remote diagnostic options and remote access via field bus in combination with a fieldbus connection. NZM-XDMI-DPV1 remote parameter definition . Only for use in combination with circuit-breakers with electronic releases. Can be used for: NZM2, NZM2-4, NZM3, NZM3-4, NZM4, NZM4-4

More details


PLC's > Fieldbus, decentr. periphery - communication module

Circuit Breakers NZM Accessories

Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



General specifications

Product Name
Eaton Moeller series NZM electronic accessory
Catalog Number
260217
Model Code
NZM-XDMI612
EAN
4015082602178
Product Length/Depth
53 mm
Product Height
90 mm
Product Width
107.5 mm
Product Weight
0.614 kg
Compliances
IEC
RoHS conform

Product specifications

Used with
Diagnostics, communication
Special features
Take appropriate measures to prevent condensation
Type
Accessory
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
Frame
NZM2/3/4
Pollution degree
2 (EMC)
Explosion safety category for dust
Other
Explosion safety category for gas
None
Mounting method
Top-hat rail IEC/EN 60715, 35 mm
Front build in possible
Rail mounting possible
Voltage type
DC
Mounting position
Vertical or horizontal
Dimensions
107.5 mm x 90 mm x 53 mm
Ambient operating temperature (LCD display)
0 °C - 55 °C
Safety performance level (EN ISO 13849-1)
None
SIL (IEC 61508)
None
Vibrations at constant acceleration 2 g (IEC/EN 60068-2-6)
57 Hz - 150 Hz
Vibrations at constant amplitude .15 mm (IEC/EN 61131-2:2008)
10 Hz - 57 Hz
Ambient operating temperature - min
0 °C
Ambient operating temperature (LCD display) - max
55 °C
Ambient storage temperature - max
70 °C
Ambient storage temperature - min
-40 °C
Drop height (IEC/EN 60068-2-31)
50 mm
Heat dissipation of power supply at 24 V DC
5 W
Power supply admissable - max
28.8 VDC
Number of module space units (total)
6
Degree of protection
IP20
Corrosion resistance
1 cm³/m³ (4 days SO₂)
10 cm³/m³ (4 days SO₂)
Shock resistance
18 impacts (IEC 60068-2-27)
System accessory
No
Voltage dips
10 ms
Operating air pressure - max
1080 hPa
Operating air pressure - min
795 hPa
Packaged free fall height (IEC/EN 60068-2-32)
1 m
Power supply admissable - min
20.4 VDC
Relative humidity - max
95 %
Residual ripple - max
5 %
Supply voltage at AC, 50 Hz - max
0 V
Supply voltage at AC, 50 Hz - min
0 V
Supply voltage at AC, 60 Hz - max
0 V
Supply voltage at AC, 60 Hz - min
0 V
Supply voltage at DC - max
24 V
Supply voltage at DC - min
24 V
Rated current of power supply
210 mA (24 V DC)

ETIM for 260217 PLC's (EC001604)
Feature Name Feature Value
Supply voltage AC 50 Hz (EF007532) 0 V
Supply voltage AC 60 Hz (EF007533) 0 V
Supply voltage DC (EF007534) 24 V
Voltage type (supply voltage) (EF002991) DC
Supporting protocol for EtherCAT (EF017564) No
Supporting protocol for TCP/IP (EF003050) No
Supporting protocol for PROFIBUS (EF003052) No
Supporting protocol for CAN (EF003053) No
Supporting protocol for INTERBUS (EF003054) No
Supporting protocol for ASI (EF003051) No
Supporting protocol for KNX (EF003055) No
Supporting protocol for Modbus (EF003057) No
Supporting protocol for Data-Highway (EF003058) No
Supporting protocol for DeviceNet (EF003059) No
Supporting protocol for SUCONET (EF003060) No
Supporting protocol for LON (EF003017) No
Supporting protocol for SERCOS (EF006657) No
Supporting protocol for PROFINET IO (EF007525) No
Supporting protocol for PROFINET CBA (EF007524) No
Supporting protocol for Foundation Fieldbus (EF007522) No
Supporting protocol for EtherNet/IP (EF007521) No
Supporting protocol for AS-Interface Safety at Work (EF007519) No
Supporting protocol for DeviceNet Safety (EF007520) No
Supporting protocol for INTERBUS-Safety (EF006662) No
Supporting protocol for PROFIsafe (EF007526) No
Supporting protocol for SafetyBUS p (EF007527) No
Supporting protocol for other bus systems (EF003062) No
Radio standard Bluetooth (EF007178) No
Radio standard WLAN 802.11 (EF007179) No
Radio standard GPRS (EF008523) No
Radio standard eGPRS (EF009703) No
Radio standard GSM (EF008524) No
Radio standard LTE (EF009709) No
Radio standard UMTS (EF008525) No
IO link master (EF007298) No
System accessory (EF004118) No
Degree of protection (IP) (EF005474) IP20
With potential separation (EF003272) No
Fieldbus connection over separate bus coupler possible (EF004002) No
Suitable for rail mounting (EF003972) Yes
Wall mounting/direct mounting (EF007020) No
Front built-in possible (EF007016) Yes
Rack-assembly possible (EF007018) No
Suitable for safety functions (EF001597) No
SIL according to IEC 61508 (EF009889) None
Performance level according to EN ISO 13849-1 (EF007399) None
Appendant operation agent (Ex ia) (EF004141) No
Appendant operation agent (Ex ib) (EF004142) No
Explosion safety category for gas (EF003997) None
Explosion safety category for dust (EF003998) Other
Certified for UL hazardous location class I (EF017622) No
Certified for UL hazardous location class II (EF017625) No
Certified for UL hazardous location class III (EF017627) No
Certified for UL hazardous location division 1 (EF017628) No
Certified for UL hazardous location division 2 (EF017629) No
Certified for UL hazardous location group A (acetylene) (EF017632) No
Certified for UL hazardous location group B (hydrogen) (EF017633) No
Certified for UL hazardous location group C (ethylene) (EF017635) No
Certified for UL hazardous location group D (propane) (EF017636) No
Certified for UL hazardous location group E (metal dusts) (EF017637) No
Certified for UL hazardous location group F (carbonaceous dusts) (EF017638) No
Certified for UL hazardous location group G (non-conductive dusts) (EF017639) No
Width (EF000008) 107.5 mm
Height (EF000040) 90 mm
Depth (EF000049) 53 mm

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.