SPCT2-175/1 167588 EATON ELECTRIC Plug-in surge arresters, 1p, 175VAC, 20 kA View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

SPCT2-175/1 167588 EATON ELECTRIC Plug-in surge arresters, 1p, 175VAC, 20 kA

SPCT2-175/1

167588

EATON-MOELLER

Plug-in surge arresters, 1p, 175VAC, 20 kA

SPCT2-175/1

More details


Earthing, lightning and surge protection > Surge protection device for power supply systems

Modular Switchgear – Industrial

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Plug-in surge arresters, 1p, 175VAC, 20 kA
For protecting consumer systems against transient overvoltages caused by indirect lightning strikes and switching operations, test class II according to IEC 61643-1+A1, SPD-type T2 according to EN 61643-11, SPC-S-HK auxiliary contact for remote signaling can be added, can be bussed with all Xtra Combinations switchgear caused by indirect lightning strikes and switching operations, test class II according to IEC 61643-1+A1, SPD-type T2 according to EN 61643-11, SPC-S-HK auxiliary contact for remote signaling can be added, can be bussed with all Xtra Combinations switchgear

Delivery program

Products
Surge arresters
Application field
Residential buildings
Utility buildings
Open areas

Technical data ETIM 7.0

Earthing, lightning and surge protection (EG000021) / Surge protection device for power supply systems (EC000941)
Electric engineering, automation, process control engineering / Protection installation, device (electric) / Surge protection device (inner lightning protection) / Surge protection device for power supply systems ([email protected] [ACN278011])
System configuration DC
No
System configuration IT
No
System configuration TN
Yes
System configuration TN-C
No
System configuration TN-C-S
No
System configuration TN-S
No
System configuration TT
No
System configuration other
Yes
Number of conductors (without earthing)
1
Nominal discharge surge current (8/20)
20 kA
Nominal voltage AC
175 V
Nominal voltage DC
0 V
Short-circuit breaking capacity (Isccr)
0 kA
Max. continuous voltage AC
175 V
Max. discharge surge current (8/20)
40 kA
Max. continuous voltage DC
0 V
Mounting method
DIN rail (top hat rail) 35 mm
Construction size
1 modular spacing
Max. PV-voltage
0 V
Voltage protection level
1 kV
Max. conductor cross section solid (solid, stranded)
25 mm²
Max. conductor cross section flexible (fine-strand)
35 mm²
Voltage protection level L-N
0 kV
Voltage protection level N-PE
0 kV
With remote signalling contact
No
Integrated backup fuse
No
Signalling at the device
Optic
Category type 2
Yes
Degree of protection (IP)
IP20

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.