E57-30GS10-D1 135974 EATON ELECTRIC Proximity switch, inductive, 1 N/C, Sn 10mm, 2L, 10-30VDC, M30, metal, l.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

E57-30GS10-D1 135974 EATON ELECTRIC Proximity switch, inductive, 1 N/C, Sn 10mm, 2L, 10-30VDC, M30, metal, l..

E57-30GS10-D1

135974

EATON-MOELLER

Proximity switch, inductive, 1 N/C, Sn=10mm, 2L, 10-30VDC, M30, metal, line 2m

E57-30GS10-D1

Proximity switch, E57 Global Series, 1 NC, 2-wire, 10 - 30 V DC, M30 x 1.5 mm, Sn= 10 mm, Flush, NPN/PNP, Metal, 2 m connection cable

More details


Sensors > Inductive proximity switch

Sensors

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Proximity switch, E57 Global Series, 1 NC, 2-wire, 10 - 30 V DC, M30 x 1.5 mm, Sn= 10 mm, Flush, NPN/PNP, Metal, 2 m connection cable
Proximity switch, Inductive Sensors, Product range: E57 Global Series, Connection: 2-wire, Design (outer dimensions): M30 x 1.5 mm, Rated operational voltage: Ue= 10 - 30 V DC, Rated switching distance: Sn= 10 mm, Type of mounting: Flush, 2 m connection cable, Contacts N/C = Normally closed: 1 NC, Material: Metal, Degree of Protection: IP67, IP69K, Standards: IEC/EN 60947-5-2

Delivery program

Basic function
Inductive Sensors
Product range
E57 Global Series
Connection
2-wire
Design (outer dimensions)
M30 x 1.5 mm
Rated operational voltage [Ue]
10 - 30 V DC
Rated switching distance [Sn]
10 mm
Type of mounting
Flush
Switching type
NPN/PNP
For connection of:
2 m connection cable
Contacts
N/C = Normally closed
1 NC
Material
Metal
Degree of Protection
IP67, IP69

Technical data

General
Standards
IEC/EN 60947-5-2
Ambient temperature
-25 - +70
Mechanical shock resistance
30
Shock duration 11 ms g
Degree of Protection
IP67, IP69
Characteristics
Rated switching distanceRated switching distance [Sn]
10 mm
Repetition accuracy of Sn
2 %
Temperature drift of Sn
10 %
Switching hysteresis of Sn
15 %
Rated operational voltage [Ue]
10 - 30 V DC
Residual ripple of Ue
10 %
Maximum load current [Ie]
< 100 mA
Operating current in the switched state at 24 V DC [Ib]
10 mA
Voltage drop at Ie[Ud]
1.5 V
Switching Frequency
500 Hz
Min. load current [Ie]
3 mA
Residual current through the load in the blocked state at 230 V AC and 24 V DC [Ir]
0.8 mA
Switching state display
Red LED
Connection
2-wire
ContactsN/C = Normally closed
1 NC
StyleDesign (outer dimensions)
M30 x 1.5 mm
For connection of:
2 m connection cable
Material
Metal

Design verification as per IEC/EN 61439

Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+70 °C

Technical data ETIM 7.0

Sensors (EG000026) / Inductive proximity switch (EC002714)
Electric engineering, automation, process control engineering / Binary sensor technology, safety-related sensor technology / Proximity switch / Inductive proximity switch ([email protected] [AGZ376015])
Width sensor
0 mm
Height of sensor
0 mm
Length of sensor
55 mm
Diameter sensor
30 mm
Mechanical mounting condition for sensor
Concise
Switching distance
10 mm
Suitable for safety functions
No
Type of switch function
Breaker contact
Type of switching output
Two-wire
Type of electric connection
Cable
Number of semiconductor outputs with signalling function
1
Number of contact energized outputs with signalling function
0
Number of protected semiconductor outputs
0
Number of protected contact energized outputs
0
Type of actuation
Metallic Target
Type of interface
None
Type of interface for safety communication
None
Construction type housing
Cylinder, screw-thread
Coating housing
Other
Cascadable
No
Category according to EN 954-1
B
SIL according to IEC 61508
None
Performance level acc. EN ISO 13849-1
None
Max. output current at protected output
0 mA
Supply voltage
10 - 30 V
Rated control supply voltage Us at AC 50HZ
0 - 0 V
Rated control supply voltage Us at AC 60HZ
0 - 0 V
Rated control supply voltage Us at DC
10 - 30 V
Voltage type
DC
Switching frequency
500 Hz
With monitoring function downstream switching devices
No
Material housing
Metal
Compression-resistant
No
Explosion safety category for gas
None
Explosion safety category for dust
None
Interference resistance to magnetic fields

Approvals

Product Standards
UL 508; CSA-C22.2 No. 14; IEC60947-5-2; CE marking
UL File No.
CSA report applies to both Canada and US
UL Category Control No.
CSA File No.
224447
CSA Class No.
4652-04 / 4652-84
North America Certification
CSA certified, certified by CSA for use in the US
Max. Voltage Rating
30 V DC
Degree of Protection
IEC: IP67, IP69K; UL/CSA Type: -

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.