ANUNCIAR
DIL-SWD-32-001 118560 Y7-118560 EATON ELECTRIC Function element, contactor, SmartWire-DT, DIL/MSC View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

DIL-SWD-32-001 118560 Y7-118560 EATON ELECTRIC Function element, contactor, SmartWire-DT, DIL/MSC

DIL-SWD-32-001

118560

Y7-118560

EATON-MOELLER

5

Function element, contactor, SmartWire-DT, DIL/MSC

DIL-SWD-32-001

Eaton Moeller® series DIL-SWD Function element, contactor, SmartWire-DT, DIL/MSC

Function element, Connection to SmartWire-DT: yes, For use with: DILM(C)7… - DILM(C)32…, DILM38…, DILA…, DILMP20…, DILMP32…, DILMP45…, MSC-D(E)-...(24VDC)

More details


PLC's > Fieldbus, decentr. periphery - digital I/O module

Contactors up to 170A

Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total: $311.22
Unit price: $62.24
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

Best sellers

More info



General specifications

Product Name
Eaton Moeller® series DIL-SWD SWD contactor module
Catalog Number
118560
Model Code
DIL-SWD-32-001
EAN
4015081168309
Product Length/Depth
72 mm
Product Height
38 mm
Product Width
45 mm
Product Weight
0.04 kg
Certifications
CSA File No.: 2324643
CSA Class No.: 3211-07
CSA-C22.2 No. 14-05
UL
UL File No.: E29184
CSA
IEC/EN 61131-2
UL Category Control No.: NKCR
CE
EN 50178
IEC/EN 60947
IEC/EN 60947-4-1
UL 508

Features & Functions

Features
Fieldbus connection over separate bus coupler possible
Functions
Contactor actuation
Display of Switch status Contactor, status of the digital inputs 1 and 2
For connecting the contactors to SmartWire-DT
Fitted with:
Own supply
Electric connection type
Spring clamp connection

General

Cable length
≤ 2.8 m, Connection auxiliary contact
Current consumption
40 mA, SmartWire-DT network
Input current at signal 1
3 mA
Number of inputs (digital)
2
Number of outputs (digital)
1
Output current
0.5 A
Overvoltage category
II
Pollution degree
2
Product category
SmartWire-DT slave
Protocol
Other bus systems
Type
SWD contactor modules
Voltage type
DC

Ambient conditions, mechanical

Constant acceleration
1 g, 8.4 - 150 Hz, according to IEC/EN 61131-2, Vibrations
Constant amplitude
3,5 mm, 5 - 8.4 Hz, according to IEC/EN 61131-2, Vibrations
Drop and topple
50 mm Drop height, Drop to IEC/EN 60068-2-31
Height of fall (IEC/EN 60068-2-32) - max
0.3 m
Mounting position
As DILM7 to DILM38
Shock resistance
15 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 11 ms, 9 Impacts

Climatic environmental conditions

Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
60 °C
Ambient storage temperature - min
30 °C
Ambient storage temperature - max
70 °C
Environmental conditions
Condensation: prevent with appropriate measures
Relative humidity
5 - 95 % (non-condensing, IEC/EN 60068-2-30)
Relative humidity
5 - 95 % (non-condensing, IEC/EN 60068-2-30)

Electro Magnetic Compatibility

Air discharge
8 kV, according to IEC 61131-2, level 3, ESD
Contact discharge
4 kV, according to IEC/EN 61131-2, Level 2, ESD
Electromagnetic fields
1 V/m at 2.0 - 2.7 GHz (according to IEC/EN 61131-2:2008)
10 V/m at 80 - 1000 MHz (according to IEC/EN 61131-2:2008)
3 V/m at 1.4 - 2 GHz (according to IEC/EN 61131-2:2008)
Radiated RFI
10 V (IEC/EN 61131-2:2008, Level 3)
Radio interference class
Class A (EN 55011)

Terminal capacities

Terminal capacity
0.2 - 1.5 mm² (24 - 16 AWG), solid
0.25 - 1.5 mm², flexible with ferrule

Electrical Rating

Rated operational voltage
15 V DC (auxiliary contact)
Supply voltage at AC, 50 Hz - min
0 VAC
Supply voltage at AC, 50 Hz - max
0 VAC
Supply voltage at DC - min
15 VDC
Supply voltage at DC - max
15 VDC

Magnet system

Pick-up current
500 mA (for DILM 17-38)
188 mA (for DILM 12-15)
125 mA (for DILM 7-9)
Power consumption
3 W for DILM 7-9 (Pick-up power)
4.5 W for DILM 12-15 (Pick-up power)
4.5 W for DILM 12-15 (Sealing power)
12 W for DILM 17-38 (Pick-up power)
3 W for DILM 7-9 (Sealing power)
0.5 W for DILM 17-38 (Sealing power)
Sealing current
125 mA, SmartWire-DT network for DILM 7-9
21 mA, SmartWire-DT network for DILM 17-38
188 mA, SmartWire-DT network for DILM 12-15

Communication

Addressing
Address set automatically
Connection to SmartWire-DT
Yes
Connection type
Push in terminals, Auxiliary contact
SWD: Plug, 8-pole
External device plug SWD4-8SF2-5, SmartWire-DT
LED indicator
Status indication of SmartWire-DT network: Green and orange LED
Station
SmartWire-DT slave, SmartWire-DT network

Contacts

Number of auxiliary contacts
2

Safety

Explosion safety category for dust
None
Explosion safety category for gas
None
Potential isolation
Connection auxiliary contact: no

Design verification

Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Rated operational current for specified heat dissipation (In)
0 A
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

ETIM for 118560 PLC's (EC001599)
Feature Name Feature Value
Supply voltage AC 50 Hz (EF007532) 0 V
Supply voltage AC 60 Hz (EF007533) 0 V
Supply voltage DC (EF007534) 15 V
Voltage type (supply voltage) (EF002991) DC
Number of digital inputs (EF001992) 2
Number of digital outputs (EF001993) 1
Digital inputs configurable (EF008516) No
Digital outputs configurable (EF008520) No
Input current at signal 1 (EF001428) 3 mA
Permitted voltage at input (EF007554) 15 V
Type of voltage (input voltage) (EF003033) DC
Type of digital output (EF003601) None
Output current (EF003202) 0.5 A
Permitted voltage at output (EF007553) 20.4 V
Type of output voltage (EF008222) DC
Short-circuit protection, outputs available (EF003203) No
Number of HW-interfaces industrial Ethernet (EF003020) 0
Number of interfaces PROFINET (EF006932) 0
Number of HW-interfaces RS-232 (EF003021) 0
Number of HW-interfaces RS-422 (EF003022) 0
Number of HW-interfaces RS-485 (EF003023) 0
Number of HW-interfaces serial TTY (EF003024) 0
Number of HW-interfaces parallel (EF003026) 0
Number of HW-interfaces wireless (EF006933) 0
Number of HW-interfaces USB (EF003025) 0
Number of HW-interfaces other (EF003027) 1
With optical interface (EF003028) No
Supporting protocol for EtherCAT (EF017564) No
Supporting protocol for TCP/IP (EF003050) No
Supporting protocol for PROFIBUS (EF003052) No
Supporting protocol for CAN (EF003053) No
Supporting protocol for INTERBUS (EF003054) No
Supporting protocol for ASI (EF003051) No
Supporting protocol for KNX (EF003055) No
Supporting protocol for Modbus (EF003057) No
Supporting protocol for Data-Highway (EF003058) No
Supporting protocol for DeviceNet (EF003059) No
Supporting protocol for SUCONET (EF003060) No
Supporting protocol for LON (EF003017) No
Supporting protocol for PROFINET IO (EF007525) No
Supporting protocol for PROFINET CBA (EF007524) No
Supporting protocol for SERCOS (EF006657) No
Supporting protocol for Foundation Fieldbus (EF007522) No
Supporting protocol for EtherNet/IP (EF007521) No
Supporting protocol for AS-Interface Safety at Work (EF007519) No
Supporting protocol for DeviceNet Safety (EF007520) No
Supporting protocol for INTERBUS-Safety (EF006662) No
Supporting protocol for PROFIsafe (EF007526) No
Supporting protocol for SafetyBUS p (EF007527) No
Supporting protocol for other bus systems (EF003062) Yes
Radio standard Bluetooth (EF007178) No
Radio standard WLAN 802.11 (EF007179) No
Radio standard GPRS (EF008523) No
Radio standard GSM (EF008524) No
Radio standard UMTS (EF008525) No
IO link master (EF007298) No
System accessory (EF004118) Yes
Degree of protection (IP) (EF005474) IP20
Type of electric connection (EF003961) Spring clamp connection
Time delay at signal change (EF002382) 10 ms
Fieldbus connection over separate bus coupler possible (EF004002) Yes
Suitable for rail mounting (EF003972) No
Wall mounting/direct mounting (EF007020) No
Front built-in possible (EF007016) No
Rack-assembly possible (EF007018) No
Suitable for safety functions (EF001597) No
SIL according to IEC 61508 (EF009889) None
Performance level according to EN ISO 13849-1 (EF007399) None
Appendant operation agent (Ex ia) (EF004141) No
Appendant operation agent (Ex ib) (EF004142) No
Explosion safety category for gas (EF003997) None
Explosion safety category for dust (EF003998) None
Certified for UL hazardous location class I (EF017622) No
Certified for UL hazardous location class II (EF017625) No
Certified for UL hazardous location class III (EF017627) No
Certified for UL hazardous location division 1 (EF017628) No
Certified for UL hazardous location division 2 (EF017629) No
Certified for UL hazardous location group A (acetylene) (EF017632) No
Certified for UL hazardous location group B (hydrogen) (EF017633) No
Certified for UL hazardous location group C (ethylene) (EF017635) No
Certified for UL hazardous location group D (propane) (EF017636) No
Certified for UL hazardous location group E (metal dusts) (EF017637) No
Certified for UL hazardous location group F (carbonaceous dusts) (EF017638) No
Certified for UL hazardous location group G (non-conductive dusts) (EF017639) No
Width (EF000008) 45 mm
Height (EF000040) 38 mm
Depth (EF000049) 72 mm

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.