Product name
Eaton Moeller® series M22 Accessory Bulkhead interface
Product Length/Depth
30 millimetre
Product height
30 millimetre
Product width
30 millimetre
Product weight
0.014 kilogram
Certifications
CSA Std. C22.2 No. 142
IEC 6113-2
UL 508
Certified by UL for use in Canada
UL File No.: E330994
UL Category Control No.: DUXR, DUXR7
UL
CSA-C22.2 No. 142
CE
UL report applies to both US and Canada
CSA Class No.: none
IEC/EN 6113-2
Product Sub Type
Bulkhead interface
Catalog Notes
RJ45 socket, 8/8, cat. 5e
Material
Titanium front ring
Number of poles
Eight-pole
Accessory/spare part type
Accessory
Degree of protection
IP65 (with closed cover)
IP20 (with plug connected)
NEMA 12 (with closed cover)
Lifespan, mechanical
750 insertion cycles
Climatic environmental conditions
Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
70 °C
Ambient storage temperature - min
-25 °C
Ambient storage temperature - max
80 °C
Insulation resistance
≥ 100 MΩ
Nominal voltage - max
50 V
Rated operational voltage
24 V AC
Resistance
< 30 mΩ (volume resistance)
Connection to SmartWire-DT
No
Contact material
CuSn, gold-plated
Force for positive opening - min
0 N
Heat dissipation capacity Pdiss
0 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Please enquire
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.