5/5 .
— CHE 5/6/26, 10:33 AM
Product:MTZ18-4VM DANFOSS REFRIGERATION Reciproc...

Images are for illustrative purposes only. Please refer to data sheet for details.
Reference: BF-U-2/48-E
Code: 283052
Catalog Number: Y7-283052
Manufacturer: EATON - MOELLER
Description:
Categories:
Brand new product in its original packaging covered by the warranties and certifications provided by EATON - MOELLER
Unit Price: 183,53 €
This price is per unit and is the net value (not including taxes if applicable).
Calculate price by quantity
| Quantity | Price |
|---|---|
More units, standard lead time: 5 days.
LAST VIEWED
| Product Name | Eaton xComfort BF small distribution board |
| Catalog Number | 283052 |
| Model Code | BF-U-2/48-E |
| EAN | 4015082830526 |
| Product Length/Depth | 140 mm |
| Product Height | 480 mm |
| Product Width | 600 mm |
| Product Weight | 9.4 kg |
| Compliances | RoHS conform |
| Certifications | IEC/EN 61439-1 IEC/EN 61439-3 IEC/EN 62208 |
| Type | Basic deviceBF flat DBOInstallation distribution boards |
| Application | Indoor (installation site) |
| Color | White Traffic white (RAL 9016) |
| Voltage rating at AC | 415 V AC |
| Frequency rating of contacts | 50 Hz / 60 Hz |
| Closure type | Other |
| Width in number of modular spacings | 24 |
| Mounting method | Flush mounted (plaster) Hollow-wall mounting and flush mounting DIN-rail Flush mounting Hollow wall |
| Material | Sheet steel, powder-coated |
| Degree of protection | IK07 (impact resistance) IP30 |
| Number of module space units per row | 24 |
| Number of rows | 2 |
| Terminal type | Screw terminals |
| PE and N terminal number and cross section | N: 2 x 25 mm² + 13 x 16 mm² PE: 2 x 25 mm² + 13 x 16 mm² |
| Built-in depth | 127 mm |
| Built-in height | 420 mm |
| Built-in width | 560 mm |
| Internal depth | 127 mm |
| Cover/door color | White |
| Cover/door model | Closed |
| Cover/door type | Door Single |
| Module rack type | Rail frame |
| Protective shrouding material | Metal |
| Heat diss. ambient 35°C delta T:20°C flush mount individ. encl. top(IEC 60890) | 34 W |
| Heat diss. ambient 35°C delta T:35°C flush mount individ. encl. top(IEC 60890) | 69 W |
| Ambient operating temperature details | -5 °C - 40 °C |
| 10.2.2 Corrosion resistance | Meets the product standard's requirements. |
| 10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. |
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. |
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | Meets the product standard's requirements. |
| 10.2.4 Resistance to ultra-violet (UV) radiation | Not relevant to indoor installations. |
| 10.2.5 Lifting | Does not apply to enclosures without lifting aids. |
| 10.2.6 Mechanical impact | IK07 |
| 10.2.7 Inscriptions | Meets the product standard's requirements. |
| 10.3 Degree of protection of assemblies | IP30 |
| 10.4 Clearances and creepage distances | Is the panel builder's responsibility. |
| 10.5 Protection against electric shock | < 0.1 Ω; meets the product standard's requirements. |
| 10.6 Incorporation of switching devices and components | Is the panel builder's responsibility. |
| 10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. |
| 10.8 Connections for external conductors | Is the panel builder's responsibility. |
| 10.9.2 Power-frequency electric strength | Ui = 415 V AC |
| 10.9.3 Impulse withstand voltage | Does not apply to basic enclosures as defined in EN 62208. |
| 10.9.4 Testing of enclosures made of insulating material | Does not apply to metal enclosures. |
| 10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
| 10.11 Short-circuit rating | Is the panel builder's responsibility. |
| 10.12 Electromagnetic compatibility | Is the panel builder's responsibility. |
| 10.13 Mechanical function | Meets the product standard's requirements. |
| Features | EMC-version Earthing terminal block Neutral terminal block |
| Fitted with: | Front plates Wall trough with door frame DIN rail mounting frame Neutral-/protective conductor terminal Door with Profi-Line three-point turn-lock |
| Functions | Basic device Sealable |
| Protection class | I (earthed) |
| RAL-number | 9016 |
| Special features | IP30Protection Class ISteel sheet enclosure white (RAL 9016) |
| Used with | Basic device Installation distribution board BF flat distribution board |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.
5/5 .
— CHE 5/6/26, 10:33 AM
Product:MTZ18-4VM DANFOSS REFRIGERATION Reciproc...
5/5 merci beaucoup
— sotitradim 11/29/25, 11:12 AM
Product:SL20,MNM,IP42,300lm,1H SL2MNM42H1C EATON...
4/5 a,azing to use it
— B rahul 10/4/25, 8:05 AM
Product:661601 LEGRAND URA21LED 70LM 1H IP42 NP
4/5 Amazing to use it
— B rahul 10/4/25, 8:04 AM
Product:661601 LEGRAND URA21LED 70LM 1H IP42 NP