Product successfully added to your shopping cart
DXC-EXT-LOCSIM
169034
EATON-MOELLER
1
Expansion for DC1 variable frequency drives (Local Sim)
Control signal terminal simulator, Subrange: Control signal terminal simulator, Basic function: Commissioning and testing simulator, Description: 3 digital inputs (+24 V), 1 relay output (max. 30 V DC), 3 microswitches, 1 reference value potentiometer (0 - +10 V / = 0 - fmax), For connecting to the control signal terminals on the DC1, For use with: DC1
Low-voltage industrial components > Accessories/spare parts for frequency controller
Power XL Frequency Converters
Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Part group reference (e.g. DIL) | DC1 | ||
Subrange | Control signal terminal simulator | ||
Basic function | Commissioning and testing simulator | ||
Description | 3 digital inputs (+24 V) 1 relay output (max. 30 V DC) 3 microswitches 1 reference value potentiometer (0 - +10 V / = 0 - fmax) For connecting to the control signal terminals on the DC1 | ||
For use with | DC1 |
Technical data for design verification | |||
Operating ambient temperature min. | °C | -10 | |
Operating ambient temperature max. | °C | 50 | |
IEC/EN 61439 design verification | |||
10.2 Strength of materials and parts | |||
10.2.2 Corrosion resistance | Meets the product standard's requirements. | ||
10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. | ||
10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. | ||
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects | Meets the product standard's requirements. | ||
10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. | ||
10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.2.7 Inscriptions | Meets the product standard's requirements. | ||
10.3 Degree of protection of ASSEMBLIES | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.4 Clearances and creepage distances | Meets the product standard's requirements. | ||
10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. | ||
10.8 Connections for external conductors | Is the panel builder's responsibility. | ||
10.9 Insulation properties | |||
10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. | ||
10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. | ||
10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. | ||
10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. | ||
10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. | ||
10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. | ||
10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
| Low-voltage industrial components (EG000017) / Accessories for frequency controller (EC002025) | |||
| Electric engineering, automation, process control engineering / Electrical drive / Electrical drive (accessories) / Frequency controller (accessories) ([email protected] [ACN127008]) | |||
Type of accessory | - | ||
| Product Standards | UL 508C; CSA-C22.2 No. 14; IEC/EN61800-3; IEC/EN61800-5; CE marking | ||
| UL File No. | E172143 | ||
| UL Category Control No. | NMMS, NMMS7 | ||
| CSA File No. | UL report applies to both US and Canada | ||
| North America Certification | UL listed, certified by UL for use in Canada | ||
| Specially designed for North America | No | ||
| Suitable for | Branch circuits | ||
| Degree of Protection | IEC: IP00 |
| Feature Name | Feature Value |
|---|---|
| Accessory (EF013236) | No |
| Spare part (EF013237) | No |
| Title: | Size: | Type: |
|---|---|---|
| PDF EATON STARTING CONTROLLING MOTORS EN.pdf | 37 Mbytes |
|
| PDF CATALOGUE EATON EN .pdf | 38 Mbytes |
|
| DXC-EXT-LOCSIM 169034 169034_EN.pdf | 196 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.