Product successfully added to your shopping cart
068U1034
DANFOSS REFRIGERATION
1
Orifice for expansion valve
Orifice No 04 for TUA
Orifice for expansion valve, ORF, R407C; R407A; R410A; R32; R134a/R513A; R407F; R404A/R507A; R448A; R23; R22/R407C; R508B; R449A
Home > DANFOSS REFRIGERATION
* Brand new product in its original packaging covered by the warranties and certifications provided by DANFOSS REFRIGERATION
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Temperature range [°C]: -40 - 10
Gross weight | 0.048 Kg |
Net weight | 0.042 Kg |
Volume | 0.04 Liter |
EAN | 5702422187790 |
Gross weight | 0.048 Kg |
Net weight | 0.042 Kg |
Volume | 0.04 Liter |
EAN | 5702422187790 |
Approval | EAC LLC CDC TYSK |
Direction | Straightway |
EU RoHS compliance | Yes with exemptions |
Fluid Group | 1 |
In scope of WEEE and contain batteries | No |
Orifice size | 4 |
Packing format | Multi pack |
Parts Program name | TUA |
PED category | Art. 4, par. 3 |
Product accessories | TXV accessories |
Product group | Expansion valves |
Product Name Description | Orifice for expansion valve |
Quantity per packing format | 9 pc |
Rated cap. cond. Range N [IMP] | OS=7.2 ºF tcond=100 ºF tevap=40 ºF tliq=98 ºF |
Rated cap. cond. Range N [SI] | OS=4K tcond=38 ºC tevap=4.4 ºC tliq=37 ºC |
Rated cap. R134a, Range N [kW] | 2.1 kW |
Rated cap. R134a, Range N [TR] | 0.59 TR |
Rated cap. R22, Range B [kW] | 1.8 kW |
Rated cap. R22, Range B [TR] | 0.5 TR |
Rated cap. R22, Range N [kW] | 2.6 kW |
Rated cap. R22, Range N [TR] | 0.75 TR |
Rated cap. R404A, Range B [kW] | 1.3 kW |
Rated cap. R404A, Range B [TR] | 0.37 TR |
Rated cap. R404A, Range N [kW] | 2.1 kW |
Rated cap. R404A, Range N [TR] | 0.6 TR |
Rated cap. R407C, Range B [kW] | 1.4 kW |
Rated cap. R407C, Range B [TR] | 0.41 TR |
Rated cap. R407C, Range N [kW] | 2.8 kW |
Rated cap. R407C, Range N [TR] | 0.8 TR |
Rated cap. R410A, Range N [kW] | 4.5 kW |
Rated cap. R410A, Range N [TR] | 1.3 TR |
Rated cap. R507, Range B [kW] | 1.4 kW |
Rated cap. R507, Range B [TR] | 0.41 TR |
Rated cap. R507, Range N [kW] | 2 kW |
Rated cap. R507, Range N [TR] | 0.57 TR |
Rated cap. R513A, Range N [kW] | 1.4 kW |
Rated cap. R513A, Range N [TR] | 0.39 TR |
REACH Candidate List substances | Lead (CAS no. 7439-92-1) |
Refrigerants | R22/R407C R23 R32 R407C R407F R410A R134a/R513A R407A R448A R449A R404A/R507A R508B |
SCIP dossier no. | 6fed54a1-6cec-4dc8-94c1-451bfa8f7152 |
SCIP dossier product name | TR6 adjustable |
Serviceable | No |
Temperature range [°C] [max] | 10 °C |
Temperature range [°C] [min] | -40 °C |
Temperature range [°F] [max] | 50 °F |
Temperature range [°F] [min] | -40 °F |
Type | ORF |
Used for product | TUA TUAE |
Approval | EAC LLC CDC TYSK |
Direction | Straightway |
EU RoHS compliance | Yes with exemptions |
Fluid Group | 1 |
In scope of WEEE and contain batteries | No |
Orifice size | 4 |
Packing format | Multi pack |
Parts Program name | TUA |
PED category | Art. 4, par. 3 |
Product accessories | TXV accessories |
Product group | Expansion valves |
Product Name Description | Orifice for expansion valve |
Quantity per packing format | 9 pc |
Rated cap. cond. Range N [IMP] | OS=7.2 ºF tcond=100 ºF tevap=40 ºF tliq=98 ºF |
Rated cap. cond. Range N [SI] | OS=4K tcond=38 ºC tevap=4.4 ºC tliq=37 ºC |
Rated cap. R134a, Range N [kW] | 2.1 kW |
Rated cap. R134a, Range N [TR] | 0.59 TR |
Rated cap. R22, Range B [kW] | 1.8 kW |
Rated cap. R22, Range B [TR] | 0.5 TR |
Rated cap. R22, Range N [kW] | 2.6 kW |
Rated cap. R22, Range N [TR] | 0.75 TR |
Rated cap. R404A, Range B [kW] | 1.3 kW |
Rated cap. R404A, Range B [TR] | 0.37 TR |
Rated cap. R404A, Range N [kW] | 2.1 kW |
Rated cap. R404A, Range N [TR] | 0.6 TR |
Rated cap. R407C, Range B [kW] | 1.4 kW |
Rated cap. R407C, Range B [TR] | 0.41 TR |
Rated cap. R407C, Range N [kW] | 2.8 kW |
Rated cap. R407C, Range N [TR] | 0.8 TR |
Rated cap. R410A, Range N [kW] | 4.5 kW |
Rated cap. R410A, Range N [TR] | 1.3 TR |
Rated cap. R507, Range B [kW] | 1.4 kW |
Rated cap. R507, Range B [TR] | 0.41 TR |
Rated cap. R507, Range N [kW] | 2 kW |
Rated cap. R507, Range N [TR] | 0.57 TR |
Rated cap. R513A, Range N [kW] | 1.4 kW |
Rated cap. R513A, Range N [TR] | 0.39 TR |
REACH Candidate List substances | Lead (CAS no. 7439-92-1) |
Refrigerants | R22/R407C R23 R32 R407C R407F R410A R134a/R513A R407A R448A R449A R404A/R507A R508B |
SCIP dossier no. | 6fed54a1-6cec-4dc8-94c1-451bfa8f7152 |
SCIP dossier product name | TR6 adjustable |
Serviceable | No |
Temperature range [°C] [max] | 10 °C |
Temperature range [°C] [min] | -40 °C |
Temperature range [°F] [max] | 50 °F |
Temperature range [°F] [min] | -40 °F |
Type | ORF |
Used for product | TUA TUAE |
Title: | Size: | Type: |
---|---|---|
068U1034 068U1034 EN_068U2205.pdf | 7 Mbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.