DANFOSS REFRIGERATION 068-2090 068-2090 - Image 1

Images are for illustrative purposes only. Please refer to data sheet for details.

068-2090 DANFOSS REFRIGERATION Orifice for expansion valve

Reference: 068-2090

Manufacturer: DANFOSS REFRIGERATION

Description:

Orifice for expansion valve
Orifice No 00 for T/TE 2
Orifice for expansion valve, ORF, R407A; R134a/R513A; R23; R455A; R407C; R236fa; R452A; R454C; R404A/R507A; R1234yf; R448A; R22/R407C; R449A

Categories:

  • DANFOSS REFRIGERATION

Brand new product in its original packaging covered by the warranties and certifications provided by DANFOSS REFRIGERATION

  • More Info
  • PDF
  • Reviews
Guarantee, repair and return.

Unit Price: 28,72 €

This price is per unit and is the net value (not including taxes if applicable).

Calculate price by quantity

QuantityPrice

Standard lead time: 4-5 days.

  • These delivery times are an estimate any may vary when the item order has been processed.

MORE INFO

Used for product: T 2; TE 2, Parts Program name: T2/TE2, Packing format: Multi pack, Quantity per packing format: 25

Product details

Gross weight13.411 Gram
Net weight9 Gram
Volume0.017 Liter
EAN5702422100270
TypeORF
Product groupExpansion valves
Product Name DescriptionOrifice for expansion valve
Gross weight13.411 Gram
Net weight9 Gram
Volume0.017 Liter
EAN5702422100270
TypeORF
Product groupExpansion valves
Product Name DescriptionOrifice for expansion valve

ApprovalEAC
LLC CDC TYSK
China RoHS complianceOut of scope
Contains batteriesNo
DesignSolder Adapter only
EU RoHS complianceYes with exemptions
EU RoHS exemption clause6(a)
6(c)
Fluid Group1
Orifice size00
Packing formatMulti pack
Parts Program nameT2/TE2
PED categoryArt. 4, par. 3
Product accessoriesTXV accessories
Quantity per packing format25 pc
Rated cap. cond. Range N [IMP]tcond=100 ºF
tevap=40 ºF
tliq=98 ºF
Rated cap. cond. Range N [SI]tcond=38 ºC
tevap=4.4 ºC
tliq=37 ºC
Rated cap. R1234yf, N [kW]0.87 kW
Rated cap. R1234yf, N [TR]0.25 TR
Rated cap. R134a, Range N [kW]1.2 kW
Rated cap. R134a, Range N [TR]0.34 TR
Rated cap. R22, Range B [kW]1.3 kW
Rated cap. R22, Range B [TR]0.38 TR
Rated cap. R22, Range N [kW]1.8 kW
Rated cap. R22, Range N [TR]0.51 TR
Rated cap. R404A, Range B [kW]1 kW
Rated cap. R404A, Range B [TR]0.29 TR
Rated cap. R404A, Range N [kW]1.3 kW
Rated cap. R404A, Range N [TR]0.37 TR
Rated cap. R407C, Range N [kW]1.8 kW
Rated cap. R407C, Range N [TR]0.51 TR
Rated cap. R452A, Range N [kW]1.33 kW
Rated cap. R452A, Range N [TR]0.38 TR
Rated cap. R454C, Range N [kW]1.48 kW
Rated cap. R454C, Range N [TR]0.42 TR
Rated cap. R455A, Range N [kW]1.67 kW
Rated cap. R455A, Range N [TR]0.47 TR
Rated cap. R507, Range B [kW]1 kW
Rated cap. R507, Range B [TR]0.29 TR
Rated cap. R507, Range N [kW]1.3 kW
Rated cap. R507, Range N [TR]0.37 TR
Rated cap. R513A, Range N [kW]1 kW
Rated cap. R513A, Range N [TR]0.29 TR
REACH Candidate List substancesLead (CAS no. 7439-92-1)
RefrigerantsR134a/R513A
R22/R407C
R23
R236fa
R404A/R507A
R407A
R407C
R448A
R449A
R452A
R1234yf
R454C
R455A
SCIP dossier no.c164ed45-f10d-4d73-9eae-355ccb479f4b
SCIP dossier product nameT2 /TE2 - Thermostatic Expansion Valve
ServiceableNo
Temperature range [°C] [max]10 °C
Temperature range [°C] [min]-40 °C
Temperature range [°F] [max]50 °F
Temperature range [°F] [min]-40 °F
UA addressUA_2L.png
Used for productT 2
TE 2
ApprovalEAC
LLC CDC TYSK
China RoHS complianceOut of scope
Contains batteriesNo
DesignSolder Adapter only
EU RoHS complianceYes with exemptions
EU RoHS exemption clause6(a)
6(c)
Fluid Group1
Orifice size00
Packing formatMulti pack
Parts Program nameT2/TE2
PED categoryArt. 4, par. 3
Product accessoriesTXV accessories
Quantity per packing format25 pc
Rated cap. cond. Range N [IMP]tcond=100 ºF
tevap=40 ºF
tliq=98 ºF
Rated cap. cond. Range N [SI]tcond=38 ºC
tevap=4.4 ºC
tliq=37 ºC
Rated cap. R1234yf, N [kW]0.87 kW
Rated cap. R1234yf, N [TR]0.25 TR
Rated cap. R134a, Range N [kW]1.2 kW
Rated cap. R134a, Range N [TR]0.34 TR
Rated cap. R22, Range B [kW]1.3 kW
Rated cap. R22, Range B [TR]0.38 TR
Rated cap. R22, Range N [kW]1.8 kW
Rated cap. R22, Range N [TR]0.51 TR
Rated cap. R404A, Range B [kW]1 kW
Rated cap. R404A, Range B [TR]0.29 TR
Rated cap. R404A, Range N [kW]1.3 kW
Rated cap. R404A, Range N [TR]0.37 TR
Rated cap. R407C, Range N [kW]1.8 kW
Rated cap. R407C, Range N [TR]0.51 TR
Rated cap. R452A, Range N [kW]1.33 kW
Rated cap. R452A, Range N [TR]0.38 TR
Rated cap. R454C, Range N [kW]1.48 kW
Rated cap. R454C, Range N [TR]0.42 TR
Rated cap. R455A, Range N [kW]1.67 kW
Rated cap. R455A, Range N [TR]0.47 TR
Rated cap. R507, Range B [kW]1 kW
Rated cap. R507, Range B [TR]0.29 TR
Rated cap. R507, Range N [kW]1.3 kW
Rated cap. R507, Range N [TR]0.37 TR
Rated cap. R513A, Range N [kW]1 kW
Rated cap. R513A, Range N [TR]0.29 TR
REACH Candidate List substancesLead (CAS no. 7439-92-1)
RefrigerantsR134a/R513A
R22/R407C
R23
R236fa
R404A/R507A
R407A
R407C
R448A
R449A
R452A
R1234yf
R454C
R455A
SCIP dossier no.c164ed45-f10d-4d73-9eae-355ccb479f4b
SCIP dossier product nameT2 /TE2 - Thermostatic Expansion Valve
ServiceableNo
Temperature range [°C] [max]10 °C
Temperature range [°C] [min]-40 °C
Temperature range [°F] [max]50 °F
Temperature range [°F] [min]-40 °F
UA addressUA_2L.png
Used for productT 2
TE 2

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.