ANUNCIAR
114X6003 DANFOSS REFRIGERATION OP-UPAC015COP04E View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

114X6003 DANFOSS REFRIGERATION OP-UPAC015COP04E

114X6003

DANFOSS REFRIGERATION

OP-UPAC015COP04E

Optyma™ iCO2, OP-UPAC015COP04E

More details


Home > DANFOSS REFRIGERATION

Brand new product in its original packaging covered by the warranties and certifications provided by DANFOSS REFRIGERATION

Total: $44,250.89
Unit price: $44,250.89
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Segment usage: Low Back Pressure; Medium Back Pressure, Refrigerants: R744, Compressor power supply [V]: 400/3/50, Mandatory accessory: Module controller assembly (118U5498) is not included with the unit and must be ordered separately.Oil tank (LCA006A008) upon oil charge calculation method given inside application; Note that the use of AK-CC55 single coil and AKVP pulsating expansion valve are mandatories

Product details

Gross weight360 Kilogram
Net weight340 Kilogram
Volume1744.613 Liter
EAN5702424547202
TypeOptyma™ iCO2 P04
Product groupCondensing Units
Product Name DescriptionPackage unit
Gross weight360 Kilogram
Net weight340 Kilogram
Volume1744.613 Liter
EAN5702424547202
TypeOptyma™ iCO2 P04
Product groupCondensing Units
Product Name DescriptionPackage unit

Accumulator volume [L]7.2 L
Air flow @ 50Hz [m³/h]15120 m³/h
ApplicationsHBP
LBP
MBP
ApprovalCE
UKCA
Capacity controlInverter
CE markYes
China RoHS complianceOut of scope
Compressor modelVCO015T4E
Compressor power supply [V]400/3/50
Connection typeSolder
Contains batteriesNo
DescriptionOP-UPAC015COP04E
Design Pressure High [bar]140 bar
Design Pressure Low [bar]80 bar
Electrical codeE
EU RoHS complianceYes
EU RoHS exemption clauseNo
FamilyOptyma™ iCO2
Fan blade size [mm]572 mm
Fan cowl/grill typeGrill
Fan current @ 50Hz [A]3.65 A
Fan diameter [mm]570 mm
Fan power output @ 50Hz [W]386 W
Fan power supply [V/Ph/Hz]280/339V DC
Frequency [Hz]50 Hz
Gas cooler internal volume [L]6.1 L
High value of nominal voltage at 50Hz [V]415 V
Length [mm]1350 mm
Liquid line connection [in]1/2 in
Low value of nominal voltage at 50Hz [V]400 V
Mandatory accessoryModule controller assembly (118U5498) is not included with the unit and must be ordered separately.Oil tank (LCA006A008) upon oil charge calculation method given inside application
Note that the use of AK-CC55 single coil and AKVP pulsating expansion valve are mandatories
Max pressure (PS) - high side140 bar
Max pressure (PS) - low side80 bar
MCC19 A
Min fuse rating [A]25 A
Model numberOP-UPAC015COP04E
No. of phases (compressor)3
Number of fans2
Number of receivers2
Oil separator volume [L]0.87 L
Oil typeDiamond freeze MA68
PED categoryII
Phase3
Receiver approvalCE
EAC
Receiver volume [L]7.6 L
RefrigerantsR744
RLA16.5 A
Segment usageLow Back Pressure
Medium Back Pressure
Sound pressure level 50Hz (@1 m distance) [db(A)]62 dBA
Sound pressure level 50Hz (@10 m distance) [db(A)]42 dBA
Suction connection size [in]3/4 in
Total height [mm]1692 mm
TS max43 °C
TS min-20 °C
VersionP04
Voltage 50Hz [V]400 V
Voltage 50Hz [V] [Max]415 V
Width [mm]764 mm
Accumulator volume [L]7.2 L
Air flow @ 50Hz [m³/h]15120 m³/h
ApplicationsHBP
LBP
MBP
ApprovalCE
UKCA
Capacity controlInverter
CE markYes
China RoHS complianceOut of scope
Compressor modelVCO015T4E
Compressor power supply [V]400/3/50
Connection typeSolder
Contains batteriesNo
DescriptionOP-UPAC015COP04E
Design Pressure High [bar]140 bar
Design Pressure Low [bar]80 bar
Electrical codeE
EU RoHS complianceYes
EU RoHS exemption clauseNo
FamilyOptyma™ iCO2
Fan blade size [mm]572 mm
Fan cowl/grill typeGrill
Fan current @ 50Hz [A]3.65 A
Fan diameter [mm]570 mm
Fan power output @ 50Hz [W]386 W
Fan power supply [V/Ph/Hz]280/339V DC
Frequency [Hz]50 Hz
Gas cooler internal volume [L]6.1 L
High value of nominal voltage at 50Hz [V]415 V
Length [mm]1350 mm
Liquid line connection [in]1/2 in
Low value of nominal voltage at 50Hz [V]400 V
Mandatory accessoryModule controller assembly (118U5498) is not included with the unit and must be ordered separately.Oil tank (LCA006A008) upon oil charge calculation method given inside application
Note that the use of AK-CC55 single coil and AKVP pulsating expansion valve are mandatories
Max pressure (PS) - high side140 bar
Max pressure (PS) - low side80 bar
MCC19 A
Min fuse rating [A]25 A
Model numberOP-UPAC015COP04E
No. of phases (compressor)3
Number of fans2
Number of receivers2
Oil separator volume [L]0.87 L
Oil typeDiamond freeze MA68
PED categoryII
Phase3
Receiver approvalCE
EAC
Receiver volume [L]7.6 L
RefrigerantsR744
RLA16.5 A
Segment usageLow Back Pressure
Medium Back Pressure
Sound pressure level 50Hz (@1 m distance) [db(A)]62 dBA
Sound pressure level 50Hz (@10 m distance) [db(A)]42 dBA
Suction connection size [in]3/4 in
Total height [mm]1692 mm
TS max43 °C
TS min-20 °C
VersionP04
Voltage 50Hz [V]400 V
Voltage 50Hz [V] [Max]415 V
Width [mm]764 mm

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.