ECL Comfort 120
| Gross weight | 0.485 Kilogram |
| Net weight | 0.377 Kilogram |
| Volume | 1.982 Liter |
| EAN | 5715162499177 |
| Type | ECL Comfort 120 |
| Product group | Electronic controllers |
| Gross weight | 0.485 Kilogram |
| Net weight | 0.377 Kilogram |
| Volume | 1.982 Liter |
| EAN | 5715162499177 |
| Type | ECL Comfort 120 |
| Product group | Electronic controllers |
| Actuator output load [VA] | 15 VA |
| Ambient humidity [% RH] [Max] | 95 % |
| Ambient temperature [°C] [max] | 55 °C |
| Ambient temperature [°C] [min] | -5 °C |
| Application source | On-board |
| Approval | CE EAC UKCA UA |
| CE evaluated | Yes |
| Communications | Modbus (galvanically isolated) |
| Contains batteries | No |
| Description | ECL Comfort 120 |
| EU RoHS compliance | Yes with exemptions |
| General functions | Alarm functions Circulation pump exercise Control valve exercise External override facility Frost protection Motor protection Master - Slave network Remote control connection |
| Grade of enclosure | IP41 |
| Heat curve setting for heating circuit | 6 points Slope |
| Number of 3-point motor control outputs | 1 |
| Number of comfort periods per day | 3 |
| Number of digital inputs | 1 |
| Number of heating circuits | 1 |
| Number of pumps | 1 |
| Number of relay outputs | 1 |
| Number of Sensor inputs | 4 pc |
| Power consumption [W] | 3 W |
| REACH Candidate List substances | Lead (CAS no. 7439-92-1) Lead monoxide (PbO, CAS no. 1317-36-8) Diboron trioxide (B2O3, CAS no. 1303-86-2) Lead titanium trioxide (CAS no. 12060-00-3) Disodium octaborate (CAS no. 12008-41-2) |
| Relay output inductive load [A] | 2 A |
| Relay output ohmic load [A] | 3 A |
| Relay output voltage [V] AC | 230 V |
| SCIP dossier no. | 63ff497e-8c51-4844-9537-63d1cd363aac |
| Storage temperature [°C] [Max] | 70 °C |
| Storage temperature [°C] [Min] | -40 °C |
| Supply voltage [V] AC | 230 V |
| Supply voltage [V] AC [max] | 244 V |
| Supply voltage [V] AC [min] | 207 V |
| Supply voltage frequency [Hz] | 50 Hz |
| Temperature sensors type | Pt 1000 |
| Time switch power backup [h] | 10 h |
| Time switch type | Week |
| User input type | Push buttons |
| Actuator output load [VA] | 15 VA |
| Ambient humidity [% RH] [Max] | 95 % |
| Ambient temperature [°C] [max] | 55 °C |
| Ambient temperature [°C] [min] | -5 °C |
| Application source | On-board |
| Approval | CE EAC UKCA UA |
| CE evaluated | Yes |
| Communications | Modbus (galvanically isolated) |
| Contains batteries | No |
| Description | ECL Comfort 120 |
| EU RoHS compliance | Yes with exemptions |
| General functions | Alarm functions Circulation pump exercise Control valve exercise External override facility Frost protection Motor protection Master - Slave network Remote control connection |
| Grade of enclosure | IP41 |
| Heat curve setting for heating circuit | 6 points Slope |
| Number of 3-point motor control outputs | 1 |
| Number of comfort periods per day | 3 |
| Number of digital inputs | 1 |
| Number of heating circuits | 1 |
| Number of pumps | 1 |
| Number of relay outputs | 1 |
| Number of Sensor inputs | 4 pc |
| Power consumption [W] | 3 W |
| REACH Candidate List substances | Lead (CAS no. 7439-92-1) Lead monoxide (PbO, CAS no. 1317-36-8) Diboron trioxide (B2O3, CAS no. 1303-86-2) Lead titanium trioxide (CAS no. 12060-00-3) Disodium octaborate (CAS no. 12008-41-2) |
| Relay output inductive load [A] | 2 A |
| Relay output ohmic load [A] | 3 A |
| Relay output voltage [V] AC | 230 V |
| SCIP dossier no. | 63ff497e-8c51-4844-9537-63d1cd363aac |
| Storage temperature [°C] [Max] | 70 °C |
| Storage temperature [°C] [Min] | -40 °C |
| Supply voltage [V] AC | 230 V |
| Supply voltage [V] AC [max] | 244 V |
| Supply voltage [V] AC [min] | 207 V |
| Supply voltage frequency [Hz] | 50 Hz |
| Temperature sensors type | Pt 1000 |
| Time switch power backup [h] | 10 h |
| Time switch type | Week |
| User input type | Push buttons |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE DANFOSS HEATING EN .pdf | 11 Mbytes |
|
| 100B1200 FR_100B1200.pdf | 412 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.