ECL COMFORT 310/230 V

ECL Comfort 310, LCD dot matrix, Supply voltage [V] AC: 207 - 244

More details


Home > DANFOSS HEATING

Brand new product in its original packaging covered by the warranties and certifications provided by DANFOSS HEATING

Total: $1,190.50
Unit price: $1,190.50
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



ECL COMFORT 310/230 V

Product details

Gross weight0.682 Kilogram
Net weight0.476 Kilogram
Volume4.877 Liter
EAN5710104013244
TypeECL Comfort 310
Product groupElectronic controllers
Gross weight0.682 Kilogram
Net weight0.476 Kilogram
Volume4.877 Liter
EAN5710104013244
TypeECL Comfort 310
Product groupElectronic controllers

Actuator output load [VA]15 VA
Ambient humidity [% RH] [Max]65 %
Ambient temperature [°C] [max]55 °C
Ambient temperature [°C] [min]0 °C
Application sourceBy ECL application key
ApprovalCE
Approval standardEMC-Directive: 2004/108/EC
Immunity: EN 61000-6-1:2007
Emission: EN 61000-6-3:2007
LVD directive 2006/95/EC
EN 60730
CE evaluatedYes
China RoHS complianceOut of scope
CommunicationsECL 485 Bus (non-galvanically isolated)
M-Bus
Modbus (galvanically isolated)
Contains batteriesNo
DescriptionECL COMFORT 310/230 V
DHW functionsAnti-bacteria program
Auto-tunning
Return temperature influence
Digital inputs type12 V pull-up possible
Display typeLCD dot matrix
EEE category5 small equipment (any external dimension < 50 cm)
EU RoHS complianceYes with exemptions
EU RoHS exemption clause6(c)
General functionsAlarm functions
Circulation pump exercise
Control valve exercise
External override facility
Frost protection
Holiday program
Master - Slave network
Motor protection
Remote control connection
Visible temperature logging
Grade of enclosureIP41
Heat curve setting for heating circuit6 points
Slope
In scope of WEEEYes
Number of 3-point motor control outputs3
Number of comfort periods per day3
Number of DHW circuits2
Number of DHW storage tank circuits1
Number of digital inputs4
Number of heating circuits3
Number of pumps5
Number of relay outputs6
Number of Sensor inputs10 pc
Power consumption [W]5 W
REACH Candidate List substancesLead (CAS no. 7439-92-1)
Lead monoxide (PbO, CAS no. 1317-36-8)
Diboron trioxide (B2O3, CAS no. 1303-86-2)
Lead titanium trioxide (CAS no. 12060-00-3)
6,6'-di-tert-butyl-2,2'-methylenedi-p-cresol (CAS no. 119-47-1)
Relay output inductive load [A]2 A
Relay output ohmic load [A]4 A
Relay output voltage [V] AC230 V
SCIP dossier no.ad51fccb-924b-4843-a9b7-7e3da2fef171
SCIP dossier product nameECL Comfort 310 and 210
Sensor cable length [m]200 m
Storage temperature [°C] [Max]70 °C
Storage temperature [°C] [Min]-40 °C
Supply voltage [V] AC230 V
Supply voltage [V] AC [max]244 V
Supply voltage [V] AC [min]207 V
Supply voltage frequency [Hz]50 Hz
Temperature sensors typePt 1000, configurable input
Time switch power backup [h]72 h
Time switch typeWeek
User input typeDisplay
Push-turn dial
Actuator output load [VA]15 VA
Ambient humidity [% RH] [Max]65 %
Ambient temperature [°C] [max]55 °C
Ambient temperature [°C] [min]0 °C
Application sourceBy ECL application key
ApprovalCE
Approval standardEMC-Directive: 2004/108/EC
Immunity: EN 61000-6-1:2007
Emission: EN 61000-6-3:2007
LVD directive 2006/95/EC
EN 60730
CE evaluatedYes
China RoHS complianceOut of scope
CommunicationsECL 485 Bus (non-galvanically isolated)
M-Bus
Modbus (galvanically isolated)
Contains batteriesNo
DescriptionECL COMFORT 310/230 V
DHW functionsAnti-bacteria program
Auto-tunning
Return temperature influence
Digital inputs type12 V pull-up possible
Display typeLCD dot matrix
EEE category5 small equipment (any external dimension < 50 cm)
EU RoHS complianceYes with exemptions
EU RoHS exemption clause6(c)
General functionsAlarm functions
Circulation pump exercise
Control valve exercise
External override facility
Frost protection
Holiday program
Master - Slave network
Motor protection
Remote control connection
Visible temperature logging
Grade of enclosureIP41
Heat curve setting for heating circuit6 points
Slope
In scope of WEEEYes
Number of 3-point motor control outputs3
Number of comfort periods per day3
Number of DHW circuits2
Number of DHW storage tank circuits1
Number of digital inputs4
Number of heating circuits3
Number of pumps5
Number of relay outputs6
Number of Sensor inputs10 pc
Power consumption [W]5 W
REACH Candidate List substancesLead (CAS no. 7439-92-1)
Lead monoxide (PbO, CAS no. 1317-36-8)
Diboron trioxide (B2O3, CAS no. 1303-86-2)
Lead titanium trioxide (CAS no. 12060-00-3)
6,6'-di-tert-butyl-2,2'-methylenedi-p-cresol (CAS no. 119-47-1)
Relay output inductive load [A]2 A
Relay output ohmic load [A]4 A
Relay output voltage [V] AC230 V
SCIP dossier no.ad51fccb-924b-4843-a9b7-7e3da2fef171
SCIP dossier product nameECL Comfort 310 and 210
Sensor cable length [m]200 m
Storage temperature [°C] [Max]70 °C
Storage temperature [°C] [Min]-40 °C
Supply voltage [V] AC230 V
Supply voltage [V] AC [max]244 V
Supply voltage [V] AC [min]207 V
Supply voltage frequency [Hz]50 Hz
Temperature sensors typePt 1000, configurable input
Time switch power backup [h]72 h
Time switch typeWeek
User input typeDisplay
Push-turn dial

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.