iC7-AutomationFrequency converter,air-cooledIC7-60FA3N05-302AE20F3+AGCX +BAMT+BDBA+BEF1+BF20 +DAAU IP20/Open Type, Frame: FA093~, 380-500 V AC, 302 AEMC category: C3 categoryControl Panel 2.8 OPX20Standard I/O: 4xDI, 2xDI/O, 2xAI, 1xAO, 2xROFieldbus protocols enabled: Modbus TCP OS7MTOther protocols enabled: Ethernet port, no protocolFunctional Safety: STO, not upgradableOther options according to model code
iC7-Automation Frequency Converter
Brand new product in its original packaging covered by the warranties and certifications provided by DANFOSS DRIVES
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
iC7-Automation
Frequency converter,air-cooled
IC7-60FA3N05-302AE20F3+AGCX +BAMT+BDBA+BEF1+BF20 +DAAU
IP20/Open Type, Frame: FA09
3~, 380-500 V AC, 302 A
EMC category: C3 category
Control Panel 2.8 OPX20
Standard I/O: 4xDI, 2xDI/O, 2xAI, 1xAO, 2xRO
Fieldbus protocols enabled: Modbus TCP OS7MT
Other protocols enabled: Ethernet port, no protocol
Functional Safety: STO, not upgradable
Other options according to model code
| Gross weight | 75.21 Kilogram | ||
| Net weight | 62.1 Kilogram | ||
| EAN | 5715253183725 |
| Product series | +DAAU | iC7-Automation | |
| Product group | IC7-60 | iC7-60 | |
| Product category | FA | Frequency converter,air-cooled | |
| Product type | 3N | 3~ | |
| Mains voltage | 05 | 380-500 V AC | |
| Current rating | -302A | 302 A | |
| Power rating | 160 | 160 kW/250 hp | |
| Protection rating | E20 | IP20/Open Type | |
| EMC category | F3 | C3 category | |
| Cable entry and EMC plate | +AAST | Standard plate | |
| Integrated brake chopper | +ACXX | None | |
| Extra environmental protection | +AGCX | Coated boards | |
| Humidity protection device | +AHXX | None | |
| Integrated common-mode filter | +AIXX | None | |
| Mains input device | +AJXX | None | |
| DC terminals | +ALXX | None | |
| Touch protection | +AMXX | None | |
| Heat sink access panel | +APXX | None | |
| Communication interface, X1/X2 | +BAMT | Modbus TCP OS7MT | |
| Communication interface, X0 | +BBEL | Ethernet port, no protocol | |
| Standard I/O | +BDBA | 4xDI, 2xDI/O, 2xAI, 1xAO, 2xRO | |
| Functional safety | +BEF1 | STO, not upgradable | |
| Control panel | +BF20 | Control Panel 2.8 OPX20 | |
| Interface board | +BISR | MicroSD card reader and RTC | |
| Option slot A | +CAX0 | None | |
| Option slot B | +CBXX | None, not upgradable | |
| Option slot C | +CCX0 | None | |
| Option slot D | +CDX0 | None | |
| Option Slot E | +CEX0 | None | |
| Customer specific application | +DBXX | None | |
| Additional drive features 1 | +DD1X | None | |
| Additional drive features 2 | +DE2X | None | |
| Additional drive features 3 | +DF3X | None | |
| Additional drive features 4 | +DG4X | None | |
| Additional drive features 5 | +DH5X | None | |
| High speed enabled | +DI6X | No | |
| Customization file package ID | +EAXXXXXX | No customization | |
| Product software ID | +ECXXX | Latest released version | |
| Technical documentation | +EGIN | Installation guide | |
| Customer-specific label | +EJXX | None | |
| Language package | +EL01 | Global | |
| Product specific marine cert. | +VBXX | None | |
| Frame designation | FA09 | FA09 | |
| Modelcode01 | IC7-60FA3N05-302AE20F3 | ||
| Modelcode02 | +AGCX | ||
| Modelcode03 | +BAMT+BDBA | ||
| Modelcode04 | +BEF1+BF20 | ||
| Modelcode05 | +DAAU | ||
| Input Voltage | 3x380-500V | 3x380-500V | |
| Input frequency | 50/60Hz | 50/60Hz | |
| Short circuit current rating | 100kA | 100kA | |
| Output frequency | 0-590Hz | 0-590Hz | |
| Typical motor power PL (110%) | 160KW(400V)/250HP(460V) | 160KW(400V)/250HP(460V) | |
| Continous current IL (1/10min) | 302/302A | 302/302A | |
| Overload current IL (1/10min) | 332/332A | 332/332A | |
| Input current LO (1/10 min) | 291/291A | 291/291A | |
| Ambient temp LO (1/10 min) | 40°C/104°F | 40°C/104°F | |
| Typical motor power PH (150%) | 132KW(400V)/200HP(460V) | 132KW(400V)/200HP(460V) | |
| Continous current IH (1/10min) | 245/240A | 245/240A | |
| Overload current IH (1/10min) | 368/360A | 368/360A | |
| Input current HO (1/10 min) | 236/231A | 236/231A | |
| Ambient temp HO (1/10 min) | 45°C/113°F | 45°C/113°F | |
| Typical motor power PH2 (150%) | 110KW(400V)/150HP(460V) | 110KW(400V)/150HP(460V) | |
| Continous current IH (1/5min) | 206/196A | 206/196A | |
| Overload current IH (1/5min) | 309/294A | 309/294A | |
| Input curent HO2 (1/5 min) | 198/189A | 198/189A | |
| Ambient temp HO2 (1/5 min) | 45°C/113°F | 45°C/113°F | |
| Efficiency class-Relative loss | IE2 - 1.93% | IE2 - 1.93% | |
| Maximum Power Loss LO [W] | 3438 | 3438 | |
| Main unit Width | 250 MM / 9.8 IN | 250 MM / 9.8 IN | |
| Main unit Height | 909 MM / 35.8 IN | 909 MM / 35.8 IN | |
| Main unit Depth | 370 MM / 14.6 IN | 370 MM / 14.6 IN | |
| Calculated Net Weight [kg] | 62.1 | ||
| Calculated Gross Weight [kg] | 75.21 | ||
| ECCN EU | Y901 | Y901 | |
| ECCN US | 3A999.a | 3A999.a | |
| Ambient temp. high overload | 45°C/113°F | 45°C/113°F | |
| Ambient temp. normal overload | 40°C/104°F | 40°C/104°F | |
| Enclosure rating | IP20 / OPEN TYPE | IP20 / OPEN TYPE | |
| Help Counter | 1 | ||
| Input current in High Overload | 236/231A | 236/231A | |
| Input current in Normal Overlo | 291/291A | 291/291A | |
| Product Catalog | NO_VIEW | NO VIEW | |
| Product View (Switch) | GLBL | Global (Standard) | |
| Typecode Part 1 | 7FC-AUFA3N05-302AE20F3 | ||
| Typecode Part 2 | -000072829 | ||
| Vendor | ERR01 | Cannot Determine Vendor |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG DANFOSS GENERAL EN.pdf | 2 Mbytes |
|
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.