131X7132 DANFOSS DRIVES VLT HVAC Drive FC 102 View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

131X7132 DANFOSS DRIVES VLT HVAC Drive FC 102

131X7132

DANFOSS DRIVES

VLT HVAC Drive FC 102

Frequency ConverterFC-102P2K2T4E21H2XGX3XXSXXXXAXBKCXXXXDX VLT® HVAC Drive FC-102(P2K2) 2.2 KW / 3.0 HP, Three phase, 380 - 480 VAC, IP21 / Type 1RFI FilterNo brake chopperGraphical Loc. Cont. PanelNot coated PCB, Mains Disconnect + FuseLatest release std. SW.Frame: A2No A Option, MCB-101 General purp. I/ONo C1 option, No D optionOther options according to Model Code

More details


VLT FC102 HVAC - DANFOSS DRIVES

Brand new product in its original packaging covered by the warranties and certifications provided by DANFOSS DRIVES

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Frequency Converter
FC-102P2K2T4E21H2XGX3XXSXXXXAXBKCXXXXDX

VLT® HVAC Drive FC-102
(P2K2) 2.2 KW / 3.0 HP,
Three phase, 380 - 480 VAC, IP21 / Type 1
RFI Filter
No brake chopper
Graphical Loc. Cont. Panel
Not coated PCB, Mains Disconnect + Fuse
Latest release std. SW.
Frame: A2
No A Option, MCB-101 General purp. I/O
No C1 option, No D option

Other options according to Model Code

Product details

Gross weight6.016 Kilogram
Net weight5.17 Kilogram
Volume52.831 Liter
EAN5710107262533

Product View (Switch)GLBLGlobal (Standard)
Product GroupFC-VLT® HVAC Drive FC-
Series102102
Power RatingP2K2(P2K2) 2.2 KW / 3.0 HP
PhaseTThree phase
Mains Voltage4380 - 480 VAC
EnclosureE21IP21 / Type 1
RFI FilterH2RFI Filter
Brake - Safe StopXNo brake chopper
LCPGGraphical Loc. Cont. Panel
Coating PCBXNot coated PCB
Mains Option3Mains Disconnect + Fuse
Adaptation AXStandard Cable Entries
Adaptation BXNo adaptation
Software ReleaseSXXXLatest release std. SW.
Software Language PackXStandard Language Pack
A OptionAXNo A Option
B OptionBKMCB-101 General purp. I/O
C0 Option MCOCXNo C0 option
C1 OptionXNo C1 option
C Option SoftwareXXNo software option
D OptionDXNo D option
Frame SizeA2A2
Product CatalogNO_VIEWNO VIEW
Typecode Part 1FC-102P2K2T4E21H2XGX
Typecode Part 23XXSXXXXAXBKCXXXXDX
Power 110% (NO) [KW]2.22.2
Height [mm]375,0375,0
Width w/ no C options [mm]90,090,0
Width w/ two C options [mm]150,0150,0
Depth [mm]207,0207,0
Depth with Option A/B [mm]222,0222,0
kVA3.883.88
Power Loss NO [W]8888
Power Loss NO [W]8888
Continuous Current (NO) [A]5.65.6
Intermittent Current (NO) [A]6.166.16
Continuous Current (NO) [A]4.84.8
Intermittent Current (NO) [A]5.285.28
Calculated Gross Weight [kg]6.016
Calculated Net Weight [kg]5.17
ECCN EUY901Y901
ECCN US3A999.a3A999.a
VendorERR01Cannot Determine Vendor
Producing plantERR01Cannot Determine Vendor
Modelcode01FC-102P2K2T4E21H2XGX
Modelcode023XXSXXXXAXBKCXXXXDX
Delivering plantERR01ERR01

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.