131X2181
DANFOSS DRIVES
1
VLT HVAC Drive FC 102
Frequency ConverterFC-102P450T7E00H2XGC7XXSXXXXA0BXCXXXXD0 VLT® HVAC Drive FC-102(P450) 450 KW / 600 HP, Three phase, 525 - 690 VAC *, (E00) IP00 / ChassisRFI FilterNo brake chopperGraphical Loc. Cont. PanelCoated PCB, FuseLatest release std. SW.Frame: E2PROFIBUS DP MCA 101, No B OptionNo C1 option, MCB-107 24V DC backupOther options according to Model Code
VLT FC102 HVAC - DANFOSS DRIVES
Brand new product in its original packaging covered by the warranties and certifications provided by DANFOSS DRIVES
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Frequency Converter
FC-102P450T7E00H2XGC7XXSXXXXA0BXCXXXXD0
VLT® HVAC Drive FC-102
(P450) 450 KW / 600 HP,
Three phase, 525 - 690 VAC *, (E00) IP00 / Chassis
RFI Filter
No brake chopper
Graphical Loc. Cont. Panel
Coated PCB, Fuse
Latest release std. SW.
Frame: E2
PROFIBUS DP MCA 101, No B Option
No C1 option, MCB-107 24V DC backup
Other options according to Model Code
| Gross weight | 221.3 Kilogram | ||
| Net weight | 221 Kilogram | ||
| EAN | 5710107039807 |
| Product View (Switch) | GLBL | Global (Standard) | |
| Product Group | FC- | VLT® HVAC Drive FC- | |
| Series | 102 | 102 | |
| Power Rating | P450 | (P450) 450 KW / 600 HP | |
| Phase | T | Three phase | |
| Mains Voltage | 7 | 525 - 690 VAC * | |
| Possible rating issue | WARN01 | Possible Rating Issue: | |
| Enclosure | E00 | (E00) IP00 / Chassis | |
| RFI Filter | H2 | RFI Filter | |
| Brake - Safe Stop | X | No brake chopper | |
| LCP | G | Graphical Loc. Cont. Panel | |
| Coating PCB | C | Coated PCB | |
| Mains Option | 7 | Fuse | |
| Adaptation A | X | Standard Cable Entries | |
| Adaptation B | X | No adaptation | |
| Software Release | SXXX | Latest release std. SW. | |
| Software Language Pack | X | Standard Language Pack | |
| A Option | A0 | PROFIBUS DP MCA 101 | |
| B Option | BX | No B Option | |
| C0 Option MCO | CX | No C0 option | |
| C1 Option | X | No C1 option | |
| C Option Software | XX | No software option | |
| D Option | D0 | MCB-107 24V DC backup | |
| Frame Size | E2 | E2 | |
| Product Catalog | NO_VIEW | NO VIEW | |
| Typecode Part 1 | FC-102P450T7E00H2XGC | ||
| Typecode Part 2 | 7XXSXXXXA0BXCXXXXD0 | ||
| Power 110% (NO) [KW] | 450 | 450 | |
| Height [mm] | 1547,0 | 1547,0 | |
| Width w/ no C options [mm] | 585,0 | 585,0 | |
| Depth [mm] | 505,0 | 505,0 | |
| Depth with Option A/B [mm] | 505,0 | 505,0 | |
| kVA | 538 | 538 | |
| Power Loss NO [W] | 5323 | 5323 | |
| Power Loss NO [W] | 5529 | 5529 | |
| Continuous Current (NO) [A] | 470 | 470 | |
| Intermittent Current (NO) [A] | 517 | 517 | |
| Continuous Current (NO) [A] | 450 | 450 | |
| Intermittent Current (NO) [A] | 495 | 495 | |
| Calculated Gross Weight [kg] | 221.3 | ||
| Calculated Net Weight [kg] | 221 | ||
| ECCN EU | Y901 | Y901 | |
| ECCN US | 3A999.a | 3A999.a | |
| Vendor | ERR01 | Cannot Determine Vendor | |
| Producing plant | ERR01 | Cannot Determine Vendor | |
| Modelcode01 | FC-102P450T7E00H2XGC | ||
| Modelcode02 | 7XXSXXXXA0BXCXXXXD0 | ||
| Delivering plant | ERR01 | ERR01 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG DANFOSS FC102 EN.pdf | 11 Mbytes |
|
| PDF CATALOG DANFOSS GENERAL EN.pdf | 2 Mbytes |
|
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.