5/5 .
— CHE 5/6/26, 10:33 AM
Product:MTZ18-4VM DANFOSS REFRIGERATION Reciproc...

Images are for illustrative purposes only. Please refer to data sheet for details.
Reference: AQ1018
Manufacturer: CARLO GAVAZZI
Description:
Categories:
Brand new product in its original packaging covered by the warranties and certifications provided by CARLO GAVAZZI
* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.
Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.
Energy Management
Modular Smart Power Quality Analyzer
Type WM3-96
• Class 0.5 (current/voltage)
• 32-bit µP-based modular smart power quality analyzer
• Graph display (128x64 dots)
• Front size: 96x96 mm
• Measurements of single phase and system variables: W, Wdmd,
VA, VAdmd, PF, PFavg, V, A, An dmd (for all of them max. and
min. values). Energies: ±kWh, 4 quadrant varh measurement.
• Neutral current measurement
• TRMS measurement of distorted waves (voltage/current)
• Current and voltage inputs with autoranging capability
• 4x4-dgt instantaneous variable read-out
• 4x9-dgt total energies read-out
• 4x6-dgt partial energies read-out
• 48 independent energy meters to be used as single,
dual, multi-time energy management
• Sampling rate: 10 samples/s
• Harmonic distorsion analysis (FFT) up to 50th harmonic
with both graph and numerical indication (of current
and voltage)
• Harmonics source detection
• Optional RS232 + real time clock function with data
logging of alarm and MIN/MAX events, montly energy
metering recording
• Degree of protection (front): IP 65
• Up to 4 optional alarm setpoints
• Up to 4 optional pulse outputs
• Up to 4 optional analogue outputs
• Optional serial RS 422/485 output
• Universal power supply: 18 to 60VAC/DC - 90 to 260 VAC/DC
• MODBUS RTU, JBUS, N2 METASYS protocols (on request)
Product Description
32-bit µP-based smart power quality analizer with a built-in configuration key-pad.
The housing is for panel mounting and ensures a degree of protection (front) of IP 65. The instrument is par-
Type Selection
ticularly indicated for those application where there is the need to control the power supply quality. The variables being displayed are more than 400.
Ordering Key WM3-96AV53H XX XX XX XX X
Model Range code System
Power supply
Slot A Slot B Slot C Slot D Options
Range code
AV5: 240/415 VAC -
1/5 AAC
(max. 300 V (L-N)/
520 V (L-L) - 6 A) (standard)
AV7: 400/690VAC -
1/5 AAC
(max. 480V (L-N) /
Slot A (signal retransmission)
XX: None
A1: Single analogue output,
20mADC (standard)
A2: Single analogue output,
±5mADC 1)
A3: Single analogue output,
±10mADC 1)
A4: Single analogue output,
1)
Slot B (communication)
XX: None
B1: Dual analogue output,
20mADC(standard)
B2: Dual analogue output,
±5mADC 1)
B3: Dual analogue output,
±10mADC 1)
B4: Dual analogue output,
1)
Slot C (alarm or pulse out)
XX: None
R1: Single relay output, (AC1-8AAC, 250VAC) 1)
R2: Dual relay output,
(AC1-8AAC, 250VAC) 1)
O1: Single open collector output (30V/100mADC) 1)
O2: Dual open collector out-
1)
830 V (L-L) / 6 A 1)
B1:
±20mADC
Dual analogue
output,
±20mADC
W1:Dual analogue output,
put (30V/100mADC)
D1: 3 digital inputs 1)
System
20mADC(standard)
B2: Dual analogue output,
±5mADC 1)
10VDC (standard)
W2:Dual analogue output,
±1VDC1)
Slot D (alarm or pulse out)
3:One phase, three-
B3: Dual analogue output,
±10mADC1)
W3:Dual analogue output,
±5VDC1)
phase system
(3 or 4 wires, balan- ced load)
Three phase system (3 or 4 wires, unba- lanced load)
Power supply
B4: Dual analogue output,
±20mADC 1)
V1: Single analogue output,
10VDC (standard)
V2: Single analogue output,
±1VDC 1)
V3: Single analogue output,
±5VDC 1)
W4:Dual analogue output,
±10VDC1)
S1: Serial port,
RS485 multidrop, bidirectional 1)
Note:
XX: None
R2: Dual relay output,
(AC1-8AAC, 250VAC) 1)
O2: Dual open collector out- put (30V/100mADC) 1)
O4: 4open collector out- puts (30V/100mADC) 1)
V4: Single analogue output,
±10VDC1)
Slot A + Slot B
Max 4 analogue outputs
Options
L: 18 to 60VAC/DC 1)
H: 90 to 260VAC/DC
1) On request
W1:Dual analogue output,
10VDC (standard)
W2:Dual analogue output,
±1VDC 1)
W3:Dual analogue output,
±5VDC 1)
W4:Dual analogue output,
±10VDC1)
Slot C + Slot D
max 4 digital outputs
X: None
S: Serial RS232 + RTC N: With N2 Metasys protocol C:options: S+N
Specifications are subject to change without noticeWM3-96DS03031
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.
5/5 .
— CHE 5/6/26, 10:33 AM
Product:MTZ18-4VM DANFOSS REFRIGERATION Reciproc...
5/5 merci beaucoup
— sotitradim 11/29/25, 11:12 AM
Product:SL20,MNM,IP42,300lm,1H SL2MNM42H1C EATON...
4/5 a,azing to use it
— B rahul 10/4/25, 8:05 AM
Product:661601 LEGRAND URA21LED 70LM 1H IP42 NP
4/5 Amazing to use it
— B rahul 10/4/25, 8:04 AM
Product:661601 LEGRAND URA21LED 70LM 1H IP42 NP