EATON - MOELLER NZM4-XUV 266588 Y7-266588 - Image 1

Images are for illustrative purposes only. Please refer to data sheet for details.

NZM4-XUV 266588 Y7-266588 EATON ELECTRIC Undervoltage release, for delay unit

4/5 - 1 Reviews

Reference: NZM4-XUV

Code: 266588

Catalog Number: Y7-266588

Manufacturer: EATON - MOELLER

Description:

Undervoltage release, for delay unit
NZM4-XUV
Eaton Moeller series NZM - Molded Case Circuit Breaker. Undervoltage release for switch frame size NZM4, for combination with separate delay unit
Undervoltage release for switch frame size NZM4, for combination with separate delay unit

Categories:

  • Low-voltage industrial components > Under voltage coil
  • EATON - MOELLER > Circuit Breakers NZM

Brand new product in its original packaging covered by the warranties and certifications provided by EATON - MOELLER

  • More Info
  • ETIM
  • PDF
  • Reviews
Guarantee, repair and return.

Unit Price: 127,19 €

This price is per unit and is the net value (not including taxes if applicable).

Calculate price by quantity

QuantityPrice

Standard lead time: 5 days.

  • These delivery times are an estimate any may vary when the item order has been processed.

LAST VIEWED

MORE INFO

General specifications

Product Name
Eaton Moeller series NZM release
Catalog Number
266588
Model Code
NZM4-XUV
EAN
4015082665883
Product Length/Depth
107 mm
Product Height
51 mm
Product Width
64 mm
Product Weight
0.263 kg
Compliances
IEC
RoHS conform
Certifications
IEC60947
CSA (File No. 22086)
CE marking
UL (Category Control Number DIHS)
CSA-C22.2 No. 5-09
CSA (Class No. 1437-01)
CSA certified
UL (File No. E140305)
UL489
UL listed

Product specifications

Used with
NZM4(-4)
N(S)4(-4)
Type
AccessoryUndervoltage releaseUndervoltage release, off-delayed
Special features
Special releases for combining with separate delay time.For use with emergency-stop devices in connection with an emergency-stop button.not UL/CSA approvedUVU-NZM delay unit is additionally required.Cannot be installed simultaneously with separate NZM...-XHIV early-make auxiliary contact or NZM...-XA... shunt release.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
Electric connection type
Screw connection
Frame
NZM4
Number of contacts (normally open contacts)
0
Rated control supply voltage (Us) at AC, 50 Hz - max
0 V
Rated control supply voltage (Us) at AC, 50 Hz - min
0 V
Rated control supply voltage (Us) at AC, 60 Hz - max
0 V
Rated control supply voltage (Us) at AC, 60 Hz - min
0 V
Voltage rating at DC
18 V DC
Suitable for
Off-load switch
Connection type
With bolt connection
Voltage type
DC
Functions
Delayed
Terminal capacity (solid/flexible conductor)
18 - 14 AWG (1x) at shunt release
18 - 14 AWG (2x) at shunt release
0.75 mm² - 2.5 mm² (2x) for undervoltage releases, off-delayed with ferrule
18 - 14 AWG (1x) for undervoltage releases, off-delayed
0.75 mm² - 2.5 mm² (1x) at shunt release with ferrule
0.75 mm² - 2.5 mm² (2x) at shunt release with ferrule
0.75 mm² - 2.5 mm² (1x) for undervoltage releases, off-delayed with ferrule
18 - 14 AWG (2x) for undervoltage releases, off-delayed
Rated control supply voltage (Us) at DC - max
0 V
Rated control supply voltage (Us) at DC - min
0 V
Number of contacts (normally closed contacts)
0
Number of contacts (change-over contacts)
0
Undelayed short-circuit release - min
0 A
Undelayed short-circuit release - max
0 A

ETIM for 266588 Low-voltage industrial controls and switchgear (EC001022)

Feature nameRated control supply voltage AC 50 Hz (EF003978)
Feature value0 V
Feature nameRated control supply voltage AC 60 Hz (EF003979)
Feature value0 V
Feature nameRated control supply voltage DC (EF003980)
Feature value0 V
Feature nameVoltage type for actuating (EF008242)
Feature valueDC
Feature nameType of electric connection (EF003961)
Feature valueScrew connection
Feature nameNumber of contacts as normally open contact (EF008256)
Feature value0
Feature nameNumber of contacts as normally closed contact (EF008255)
Feature value0
Feature nameNumber of contacts as change-over contact (EF008257)
Feature value0
Feature nameDelayed (EF001541)
Feature valueYes
Feature nameSuitable for power circuit breaker (EF005863)
Feature valueNo
Feature nameSuitable for off-load switch (EF001543)
Feature valueYes
Feature nameSuitable for motor safety switch (EF005826)
Feature valueNo
Feature nameSuitable for overload relay (EF001545)
Feature valueNo

DATASHEET - PDF

Reviews (1)

— R Omar 10/23/17, 12:00 AM

Buen procedimiento de compra

Customer rating:

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.