EATON - MOELLER LN4-800-I 112012 Y7-112012 - Image 1

Images are for illustrative purposes only. Please refer to data sheet for details.

LN4-800-I 112012 Y7-112012 EATON ELECTRIC Switch-disconnector, 3 p, 800A, frame size 4

Reference: LN4-800-I

Code: 112012

Catalog Number: Y7-112012

Manufacturer: EATON - MOELLER

Description:

Switch-disconnector, 3 p, 800A, frame size 4
LN4-800-I
Eaton Moeller series Power Defense - Molded Case Circuit Breaker. Switch-disconnector, 3 p, 800A, frame size 4

Categories:

  • Low-voltage industrial components > Switch disconnector
  • EATON - MOELLER > Circuit Breakers LZM

Brand new product in its original packaging covered by the warranties and certifications provided by EATON - MOELLER

  • More Info
  • ETIM
  • PDF
  • Reviews
Guarantee, repair and return.

Unit Price: 1.410,67 €

This price is per unit and is the net value (not including taxes if applicable).

Calculate price by quantity

QuantityPrice
Stock delivery today. 1 units.

More units, standard lead time: 5 days.

  • These delivery times are an estimate any may vary when the item order has been processed.

LAST VIEWED

MORE INFO

General specifications

Product Name
Eaton Moeller series Power Defense molded case switch-disconnector
Catalog Number
112012
Model Code
LN4-800-I
EAN
4015081115600
Product Length/Depth
401 mm
Product Height
207 mm
Product Width
210 mm
Product Weight
17 kg
Compliances
RoHS conform
Certifications
IEC

Product specifications

Type
Switch-disconnector
Special features
Main switch characteristics including positive drive to IEC/EN 60204 and VDE 0113.Isolating characteristics to IEC/EN 60947-3 and VDE 0660.Busbar tag shroud to VDE 0160 Part 100.Rated current = rated uninterrupted current: 800 A
Application
Use in unearthed supply systems at 525 V
Amperage Rating
800 A
Voltage rating
690 V - 690 V
Circuit breaker frame type
LN4
Features
Version as main switch
Motor drive optional
Version as emergency stop installation
Version as maintenance-/service switch
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
Pollution degree
3
Mounting Method
Built-in device fixed built-in technique
Intermediate mounting
Ground mounting
Fixed
Distribution board installation
Equipment heat dissipation, current-dependent
71.04 W
Rated short-time withstand current (Icw)
25 kA
Electrical connection type of main circuit
Bolt connection
Number of auxiliary contacts (change-over contacts)
0
Number of auxiliary contacts (normally closed contacts)
0
Number of auxiliary contacts (normally open contacts)
0
Rated insulation voltage (Ui)
1000 V
Rated operating frequency
50 Hz
Rated operating power at AC-23, 400 V
450 kW
Rated operating power at AC-3, 400 V
0 kW
Switch positions
I, +, 0
Lifespan, mechanical
10000 operations
Overvoltage category
III
Rated operational current
1600 A (690 V AC-1, making and breaking capacity)
1600 A (690 V AC-22/23A, making and breaking capacity)
1600 A (415 V AC-1, making and breaking capacity)
1600 A (415 V AC-22/23A, making and breaking capacity)
Degree of protection (IP), front side
IP20
Number of poles
Three-pole
Terminal capacity (copper strip)
10 segments of 80 mm x 1 mm (2x) at rear-side width extension
Max. 10 segments of 50 mm x 1 mm (2x) at rear-side connection (punched)
Min. 10 segments of 50 mm x 1 mm (2x) at rear-side connection (punched)
10 segments of 50 mm x 1 mm (2x) at 1-hole module plate
Max. 10 segments of 32 mm x 1 mm (2x) at flat conductor terminal
Min. 6 segments of 16 mm x 0.8 mm at flat conductor terminal
Handle color
Gray
Lifespan, electrical
2000 operations at 415 V AC-3
3000 operations at 415 V AC-1
1000 operations at 690 V AC-3
3000 operations at 400 V AC-1
2000 operations at 690 V AC-1
2000 operations at 400 V AC-3
Functions
Disconnectors/main switches
Interlockable
Voltage release optional
Rated conditional short-circuit current (Iq)
100 kA
Rated conditional short-circuit current with back-up fuse
100 kA at 400/415 V
N4-630…1600: 2 x 800 AgGgL
80 kA at 690 V
Rated conditional short-circuit current with downstream fuse
100 kA at 400/415 V
N4-630…1600: 2 x 800 AgGgL
80 kA at 690 V
Short-circuit total breaktime
< 10 ms
Rated operating voltage (Ue) at AC - max
400 V
Rated operational current for specified heat dissipation (In)
800 A
Rated permanent current at AC-21, 400 V
0 A
Rated short-time withstand current (t = 0.3 s)
25 kA
Rated short-time withstand current (t = 1 s)
25 kA
Switching power at 400 V
0 kW
Handle type
Rocker lever
Number of operations per hour - max
60
Rated short-circuit making capacity Icm at 690 V, 50/60 Hz
53 kA
Rated impulse withstand voltage (Uimp) at auxiliary contacts
6000 V
Rated impulse withstand voltage (Uimp) at main contacts
8000 V
Standard terminals
Screw terminal
Terminal capacity (control cable)
0.75 mm² - 2.5 mm² (1x)
0.75 mm² - 1.5 mm² (2x)
Short-circuit protective device fuses - max
1600 A gL
Terminal capacity (copper busbar)
Max. 50 mm x 10 mm (2x) direct at switch rear-side connection
Max. 80 mm x 10 mm (2x) at rear-side width extension
Min. 25 mm x 5 mm direct at switch rear-side connection
Max. 80 mm x 10 mm (2x) direct at switch rear-side connection
50 mm x 10 mm (2x) at rear-side 2-hole module plate
M10 at rear-side screw connection
Min. 25 mm x 5 mm at rear-side 1-hole module plate
Min. 60 mm x 10 mm at rear-side width extension
Max. 50 mm x 10 mm (2x) at rear-side 1-hole module plate
Terminal capacity (copper solid conductor/cable)
35 mm² - 185 mm² (4x) at rear-side 2-hole module plate
50 mm² - 240 mm² (4x) at 4-hole tunnel terminal
300 mm² (4x) at rear-side width extension
95 mm² - 185 mm² (2x) at rear-side 2-hole module plate
120 mm² - 300 mm² (1x) at rear-side 1-hole module plate
95 mm² - 240 mm² (6x) at rear-side width extension
95 mm² - 300 mm² (2x) at rear-side 1-hole module plate
Terminal capacity (copper stranded conductor/cable)
120 mm² - 185 mm² (1x) direct at switch rear-side connection
50 mm² - 185 mm² (4x) direct at switch rear-side connection
Terminal capacity (aluminum stranded conductor/cable)
50 mm² - 240 mm² (4x) at 4-hole tunnel terminal

ETIM for 112012 Low-voltage industrial controls and switchgear (EC000216)

Feature nameVersion as main switch (EF006981)
Feature valueYes
Feature nameVersion as maintenance-/service switch (EF006986)
Feature valueYes
Feature nameVersion as safety switch (EF006985)
Feature valueNo
Feature nameVersion as emergency stop installation (EF006959)
Feature valueYes
Feature nameVersion as reversing switch (EF009408)
Feature valueNo
Feature nameMax. rated operation voltage Ue AC (EF007355)
Feature value400 V
Feature nameRated operating voltage (EF001435)
Feature value690 V
Feature nameRated permanent current at AC-21, 400 V (EF009165)
Feature value0 A
Feature nameRated operation power at AC-3, 400 V (EF001364)
Feature value0 kW
Feature nameRated short-time withstand current lcw (EF007050)
Feature value25 kA
Feature nameRated operation power at AC-23, 400 V (EF007027)
Feature value450 kW
Feature nameSwitching power at 400 V (EF009166)
Feature value0 kW
Feature nameConditioned rated short-circuit current Iq (EF001444)
Feature value100 kA
Feature nameNumber of poles (EF001391)
Feature value3
Feature nameNumber of auxiliary contacts as normally closed contact (EF001377)
Feature value0
Feature nameNumber of auxiliary contacts as normally open contact (EF001376)
Feature value0
Feature nameNumber of auxiliary contacts as change-over contact (EF003531)
Feature value0
Feature nameMotor drive optional (EF007386)
Feature valueYes
Feature nameMotor drive integrated (EF006697)
Feature valueNo
Feature nameVoltage release optional (EF007491)
Feature valueYes
Feature nameDevice construction (EF008240)
Feature valueBuilt-in device fixed built-in technique
Feature nameSuitable for front mounting 4-hole (EF007247)
Feature valueNo
Feature nameSuitable for front mounting centre (EF007248)
Feature valueNo
Feature nameSuitable for distribution board installation (EF007262)
Feature valueYes
Feature nameSuitable for intermediate mounting (EF007264)
Feature valueYes
Feature nameColour control element (EF007167)
Feature valueGrey
Feature nameType of control element (EF006976)
Feature valueRocker lever
Feature nameInterlockable (EF006281)
Feature valueYes
Feature nameType of electrical connection of main circuit (EF006819)
Feature valueBolt connection
Feature nameWith pre-assembled cabling (EF016444)
Feature valueNo
Feature nameDegree of protection (IP), front side (EF003118)
Feature valueIP20
Feature nameWidth (EF000008)
Feature value210 mm
Feature nameHeight (EF000040)
Feature value207 mm
Feature nameDepth (EF000049)
Feature value401 mm

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.