EATON - MOELLER CGVision Pro Package I 40071361021 - Image 1

Images are for illustrative purposes only. Please refer to data sheet for details.

CGVision Pro Package I 40071361021 EATON ELECTRIC Distribution board BI-7647 Package without metering applic..

Reference: CGVision Pro Package I

Code: 40071361021

Manufacturer: EATON - MOELLER

Description:

Distribution board BI-7647 Package without metering application
CGVision Pro Package I
Eaton CGL+ CGVision, CGVision Pro Package I

Categories:

  • PLC's > Visualization software
  • EATON - MOELLER > Central Battery System

Brand new product in its original packaging covered by the warranties and certifications provided by EATON - MOELLER

  • More Info
  • ETIM
  • PDF
  • Reviews
Guarantee, repair and return.

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

LAST VIEWED

MORE INFO

Distribution board BI-7647 Package without metering application
EL-Nummer (Norway)
1728160
[

Design verification as per IEC/EN 61439

Technical data for design verification
Heat dissipation, at an ambient temperature of 35°C, delta T: 20 degrees in top of the enclosure, calculated as per IEC 60890Individual enclosure for wall mounting [PV]
61 W
Heat dissipation, at an ambient temperature of 35°C, delta T: 20 degrees in top of the enclosure, calculated as per IEC 60890Starting enclosure for wall mounting [PV]
59 W
Heat dissipation, at an ambient temperature of 35°C, delta T: 20 degrees in top of the enclosure, calculated as per IEC 60890Middle enclosure for wall mounting [PV]
56 W
Heat dissipation, at an ambient temperature of 35°C, delta T: 35 degrees in top of the enclosure, calculated as per IEC 60890Individual enclosure for wall mounting [PV]
123 W
Heat dissipation, at an ambient temperature of 35°C, delta T: 35 degrees in top of the enclosure, calculated as per IEC 60890Starting enclosure for wall mounting [PV]
118 W
Heat dissipation, at an ambient temperature of 35°C, delta T: 35 degrees in top of the enclosure, calculated as per IEC 60890Middle enclosure for wall mounting [PV]
113 W
IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Not relevant to indoor installations.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply to enclosures without lifting aids.
10.2 Strength of materials and parts10.2.6 Mechanical impact
IK08
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
IP30
10.4 Clearances and creepage distances
Is the panel builder's responsibility.
10.5 Protection against electric shock
< 0.1 Ω; meets the product standard's requirements.
10.6 Incorporation of switching devices and components
Is the panel builder's responsibility.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Ui= 1890 V AC
10.9 Insulation properties10.9.3 Impulse withstand voltage
2.5 kV
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Does not apply to metal enclosures.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
Meets the product standard's requirements.
,

Technical data ETIM 7.0

Distribution boards (EG000023) / Small distribution board (EC000214)
Electric engineering, automation, process control engineering / Electrical installation, device / Electrical distribution system (incl. small distribution board) / Small distribution board (ecl@ss10.0.1-27-14-24-09 [ACN387011])
Mounting method
Surface mounted (plaster)
Number of rows
5
Width in number of modular spacings
20
Type of cover
Door
Cover model
Closed
Transparent cover/door
No
Material housing
Steel
Height
765 mm
Width
475 mm
Depth
220 mm
Built-in depth
212 mm
Internal depth
210 mm
DIN-rail
Yes
With mounting plate
No
Extension possible
No
EMC-version
Yes
Colour
White
RAL-number
9016
Degree of protection (IP)
IP30
With lock
No
Type of closure
Other
]

ETIM for 40071361021 PLC's (EC001416)

Feature nameWith OPC-interface, server (EF003172)
Feature value
Feature nameWith OPC-interface, client (EF003173)
Feature value
Feature nameWith programming interfaces (EF003174)
Feature value
Feature nameRuntime operating system, Windows XP (EF003177)
Feature value
Feature nameRuntime operating system, Windows 2000 (EF003178)
Feature value
Feature nameRuntime operating system, Linux (EF003179)
Feature value
Feature nameRuntime operation system, Windows Vista (EF007457)
Feature value
Feature nameSuitable for operating system Windows 7 (EF008526)
Feature value
Feature nameSuitable for operating system Windows 8 (EF009923)
Feature value
Feature nameSuitable for operating system Windows 10 (EF015965)
Feature value
Feature nameRuntime operating system, other (EF003180)
Feature value
Feature nameLoadable for operating system for configuration software, Windows 9x (EF003183)
Feature value
Feature nameLoadable for operating system for configuration software, Windows NT (EF003186)
Feature value
Feature nameLoadable for operating system for configuration software, Windows 2000 (EF003187)
Feature value
Feature nameLoadable for operating system for configuration software, Windows XP (EF003188)
Feature value
Feature nameLoadable for operating system for configuration software, Linux (EF003190)
Feature value
Feature nameLoadable for operating system for configuration software, Windows ME (EF003189)
Feature value
Feature nameLoadable for operating system for configuration software, Windows Vista (EF007417)
Feature value
Feature nameLoadable for operating system for configuration software, Windows 2003 Server (EF007416)
Feature value
Feature nameLoadable for operating system for configuration software, Windows 7 (EF008865)
Feature value
Feature nameLoadable for operating system for configuration software, Windows 8 (EF009924)
Feature value
Feature nameMin. required main memory for runtime system (EF003176)
Feature valueNone MB
Feature nameMin. required main memory for configuration software (EF003182)
Feature valueNone MB
Feature nameIndustry- and technological expansions (EF003151)
Feature value
Feature nameMulti-user capable, runtime (EF003152)
Feature value
Feature nameMax. number of servers (EF003153)
Feature value
Feature nameMax. number of clients (EF003154)
Feature value
Feature nameSuitable for web-clients (EF003155)
Feature value
Feature nameSCADA functionality (EF007458)
Feature value
Feature nameAlarm-management (EF006805)
Feature value
Feature nameTrend representation (EF007510)
Feature value
Feature nameMax. number of multi-users configuration (EF003157)
Feature value
Feature nameOnline projecting possible (EF003158)
Feature value
Feature nameIntegrable in the engineering software o.t autom.system (EF003159)
Feature value
Feature nameNumber of online/runtime languages (EF003160)
Feature value
Feature nameLanguage switch possible (EF007493)
Feature value
Feature nameNumber of configuration-/runtime languages (EF003161)
Feature value
Feature nameNumber of configuration-/desktop languages (EF003162)
Feature value
Feature nameWith script language Visual Basic (EF003163)
Feature value
Feature nameWith other script language (EF003164)
Feature value
Feature nameLibrary with object elements (EF003165)
Feature value
Feature nameUser groups (password protection) possible (EF003166)
Feature value
Feature nameMessage system (EF003167)
Feature value
Feature nameUser archive/recipes management (EF003168)
Feature value
Feature nameReporting system/protocol system (EF003169)
Feature value
Feature nameFunction process diagnostics (EF003170)
Feature value
Feature nameSQL-database (EF003171)
Feature value
Feature nameMin. required processor speed for runtime system (EF003175)
Feature valueNone GHz
Feature nameMin. required processor speed for configuration software (EF003181)
Feature valueNone GHz

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.