CLP2EA1C230 CARLO GAVAZZI Selected parameters SYSTEM System HOUSING Rectangular SENSING FUNCTION Filling or .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

CLP2EA1C230 CARLO GAVAZZI Selected parameters SYSTEM System HOUSING Rectangular SENSING FUNCTION Filling or ..

CLP2EA1C230

CLP2EA1C230

CARLO GAVAZZI

Available

Ship on today

Selected parameters SYSTEM System HOUSING Rectangular SENSING FUNCTION Filling or Emptying CONNECTION Plug and socket OUTPUT Relay DPDT MATERIAL Plastic Others HOUSING 35,5 x 81 x 63 mm SENSING FUNCTION 250 oHm to 500 koHm MATERIAL NORYL

More details


Level Sensors Detectors Measurement

Sensors

Conductive Level Sensors

* Brand new produt in its original packing covered by the warranties and certifications provided by CARLO GAVAZZI

QuantityPrice
1+61,87 €
3+58,84 €
6+57,39 €
9+56,67 €
12+56,22 €
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Conductive Sensors
2-point level controller
Type CL with potentiometer
• Conductive level controller
• Sensitivity adjustment from 250 Ω to 500 KΩ
• For filling or emptying applications
• Low-voltage AC electrodes
• Easy installation on DIN rails or with 11 pin circular plug
• Rated operational voltage:
24 VAC/DC, 115 VAC or 230 VAC
• Output 2 x 8A/250 VAC DPDT relay
• LED indication for: Output ON and Power ON
Product Description
Ordering Key
CLD2EA1CM24
µ-Processor based level controller for liquids with a wide sensitivity range (like sewage water, chemicals, salt water etc.).
Type Selection
Max./min. control of charging/ discharging. The sensitivity is adjustable by means of the potentiometerand the rotary switch.
2 x 8A DPDT relay output.
Conductive level
DIN rail or plug mounting No of inputs Charge/discharge Adjustment potentiometer Output
Relay DPDT Power supply
MountingRelay Ordering no. Ordering no. Ordering no.
Supply: 24 VAC/DCSupply: 115 VACSupply: 230 VAC
DIN-railDPDT CLD2EA1CM24CLD2EA1C115 CLD2EA1C230
11-p circular plug CLP2EA1CM24CLP2EA1C115CLP2EA1C230
Specifications
Rated operational voltage (UB)
Pin 2 & 10 230195 to 265 VAC, 45 to 65 Hz
11598 to 132 VAC, 45 to 65 Hz
Supply class 2 2419.2 to 28.8 VAC/DC Rated insulation voltage <2.0 kVAC (rms) Rated impulse withstand
voltage4 kV (1.2/50 µs) (line/neutral)
Rated operational power
AC supply 5 VA AC/DC supply 5 VA / 5 W
Delay on operate (tV) < 300 mS
Outputs
Rated insulation voltage 250 VAC (rms) (cont./elec.)
Relay Rating (AgCdO) µ (micro gap)
Resistive loads AC1 8 A / 250 VAC (2500 VA) DC1 1 A / 250 VDC (250 W)
or 10 A / 25 VDC (250 W) Small induc. LoadsAC15 0,4 A / 250 VAC
DC13 0,4 A / 30 VDC Mechanical life (typical)≥30 x 106 operations
@ 18’000 imp/h
Electrical life (typical) AC1 > 250’000 operations
Level probe supply Max. 5 VAC Level probe current Max. 2 mA Sensitivity250Ω to 500KΩ
Factory settings standard
range “S” 100KΩ
Ranges L (Low sensitivity)250 Ω to 5 KΩ, CF* = 4.7 nF
Ranges S (Standard sensitivity) 5 KΩ to 100 KΩ, CF* = 2.2 nF Ranges H (High sensitivity) 50 KΩ to 500 KΩ, CF* = 1.0 nF
Dielectric voltage>2.0 KVAC (rms) (contacts / electronics)
Rated impulse withstand volt. 4 kV (1.2/50 µS) (contacts /
electronics) (IEC 664)
Operating frequency (f)
Relay output0.5 HZ
Response time
OFF-ON (ton)1 s
ON-OFF (toff)1 s
Environment
Overvoltage category III (IEC 60664)
Degree of protection IP 20 (IEC 60529, 60947-1) Pollution degree 2 (IEC 60664/60664A,
60947-1)
Temperature
Operating-20º to +50ºC (-4º to + 122ºF) Storage -50º to +85ºC (-58º to +185ºF)
Housing materialCLP NORYL PPO, light grey
CLD ABS VO, light grey
Weight
AC supply 200 g
AC/DC supply 125 g
UL Approvals cURus UL508, UL325, CSA-C22.2
No.247
CE markingYes
*CF = maximum Cable Capacitance
Specifications are subject to change without notice (20.05.2014) 1

Datasheet - PDF

Title:Language:Size:Type:
pdf1-mostradoSelected parameters SYSTEM System HOUSING Rectangular SENSING FUNCTION Filling or Emp - CARLO GAVEnglish357 Kbytespdf1-mostradoSelected parameters SYSTEM System HOUSING Rectangular SENSING FUNCTION Filling or Emp - CARLO GAV
pdf1-Selected parameters SYSTEM System HOUSING Rectangular SENSING FUNCTION Filling or Emp - CARLO GEnglish12 Mbytespdf1-mostradoSelected parameters SYSTEM System HOUSING Rectangular SENSING FUNCTION Filling or Emp - CARLO GAV
pdf2-mostradoSelected parameters SYSTEM System HOUSING Rectangular SENSING FUNCTION Filling or Emp - CARLO GAVEnglish200 Kbytespdf1-mostradoSelected parameters SYSTEM System HOUSING Rectangular SENSING FUNCTION Filling or Emp - CARLO GAV

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review