Selected parameters SYSTEM System HOUSING 1-DIN SENSING FUNCTION Filling or Emptying CONNECTION Terminals OUTPUT Relay SPST MATERIAL Plastic Others HOUSING 17,5 x 81 x 60 mm SENSING FUNCTION 5 koHm to 150 koHm MATERIAL NORYL ADDITIONAL Time Dependent Level

More details


Level Sensors Detectors Measurement

Sensors

Conductive Level Sensors

* Brand new product in its original packaging covered by the warranties and certifications provided by CARLO GAVAZZI

Quantity Price
1+$65.55
7+$56.76
13+$54.96
19+$54.06
26+$53.41
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Conductive Sensors
1-point Basic Level Controller
Type CL with Potentiometer and Time Control
• Conductive level controller
• Sensitivity adjustment 5 KΩ to 150 KΩ
• For filling or emptying applications
• Low-voltage AC electrodes
• Easy installation on DIN rails 17.5 mm
• Rated operational voltage: 24 VAC/DC
• Output 8A/250 VAC SPST relay
• LED indication for: Output ON, Power ON
Product Description
Ordering Key
CLD1EA1CM24
µ-Processor based level controllerforliquidswitha widesensitivityrangefrom
5 KΩ to 150 KΩ.
Type Selection
One probe level controlwith built in ON or OFF time delay for filling or emptying applica- tions. The time delay can be set from 1 to 30 seconds.
Type
DIN rail mounting
Inputs Function Adjustment Outputs
Relay versions
Power supply
Mounting Ordering no.
Supply: 24 VAC/DC
DIN-rail CLD1EA1CM24
Specifications
Rated operational voltage (UB)
Supply class 2
Pin A1 & A22419.2 to 28.8 VAC/DC Rated insulation voltage <2.0 kVAC (rms) Rated impulse withstand
voltage4 kV (1.2/50 µs) (line/neutral)
Rated operational power
AC/DC supply 5 VA / 5 W Delay on operate (tV) < 300 mS Outputs
Rated insulation voltage 250 VAC (rms) (cont./elec.)
Relay Rating (AgCdO) µ (micro gap)
Resistive loads AC1 8 A / 250 VAC (2500 VA) DC1 1 A / 250 VDC (250 W)
or 10 A 25 VDC (250 W) Small induc. LoadsAC15 0,4 A 250 VAC
DC13 0,4 A / 30 VDC Mechanical life (typical)≥30 x 106 operations
@ 18’000 imp/h
Electrical life (typical) AC1 > 250’000 operations
Level probe supplyMax. 5 VAC
Level probe current Max. 2 mA
Sensitivity5 KΩ to 150 KΩ, CF = 2.2 nF* Factory preset 150 KΩ
*CF = maximum Cable Capacitance
Dielectric voltage>2.0 KVAC (rms) (contacts / electronics)
Rated impulse withstand volt. 4 kV (1.2/50 µS) (contacts /
electronics) (IEC 664)
Operating frequency (f) max
Relay output0.5 Hz
Response time
OFF-ON (ton)1 sec to 30 sec adjustable
ON-OFF (toff)1 sec to 30 sec adjustable
Environment
Overvoltage category III (IEC 60664)
Degree of protection IP 20 /IEC 60529, 60947-1) Pollution degree2 (IEC 60664/60664A,
60947-1)
Temperature
Operating-20º to +50ºC (-4º to + 122º) Storage -50º to +85ºC (-58º to +185ºF)
Housing material ABS VO, light grey
Weight
AC/DC supply 125 g
Approvals
ULcus UL508, UL325, CSA-C22.2
No.247
CSAYes
CE markingYes
Specifications are subject to change without notice (26.10.2010)1

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.