Selected parameters OUTPUT SIGNAL 1 relay SETPOINTS 1, fixed MONITORED VARIABLE 3-phase AC voltage monitoring Others SIZE 22,5 mm POWER SUPPLY RANGE 380÷415 VAC MONITORING FUNCTION Phase sequence MOUTING DIN-rail INPUT RANGE 380÷415 VAC

More details


Energy Meters Control Analizers

Controls

Monitoring Relays and Measurement Current Transformers

* Brand new produt in its original packing covered by the warranties and certifications provided by CARLO GAVAZZI

QuantityPrice
1+68,29 €
3+65,04 €
6+63,48 €
8+62,92 €
11+62,39 €
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Monitoring Relays
3-Phase Sequence
Types DPA02, PPA02
• 3-Phase monitoring relays for phase sequence
• Measure their own power supply
• Power supply range: 208 to 240 and 380 to 415 VAC (±15%)
• Output 8 A SPDT relay normally energized
• For mounting on DIN-rail in accordance with DIN/EN
50 022 or Plug-in module
• 22.5 mm Euronorm housing (DPA02) or 36 mm Plug- in module (PPA02)
• LED indication for relay ON
DPA02 PPA02
Product DescriptionOrdering Key
DPA 02 C M40
3-phaserelay fordetection of incorrect phase sequence. Supplyrangefrom208to
240and380to415VAC
covered by two multi voltage relays. For mountingon DIN-rail or Plug-in module.
Housing Function Type
Item number
Output
Power supply
Type Selection
MountingOutput Supply: 208-240 VAC Supply: 380-415 VAC
DIN-railSPDT DPA 02 C M23 DPA 02 C M40
Plug-in SPDT PPA 02 C M23 PPA 02 C M40
InputSpecifications
Input
L1, L2, L3DPA02: Terminals L1, L2, L3
PPA02: Terminals 5, 6, 7
Measure their own supply
Measuring ranges
208 to 240 VAC177 to 275 VAC
380 to 415 VAC323 to 475 VAC
Supply Specifications
Power supplyOvervoltage cat. III Rated operational voltage (IEC 60664, IEC 60038) through terminals:
L1, L2, L3 (DPA02)
5, 6, 7 (PPA02)
Output Specifications
OutputSPDT relay, N.E. Rated insulation voltage 250 VAC Contact ratings (AgSnO2) µ
Resistive loadsAC 1 8 A @ 250 VAC
DC 12 5 A @ 24 VDC Small inductive loads AC 15 2.5 A @ 250 VAC
DC 13 2.5 A @ 24 VDC
Mechanical life≥ 30 x 106 operations
Electrical life≥ 105 operations
(at 8 A, 250 V, cos ϕ = 1)
Operating frequency ≤ 7200 operations/h
Dielectric strength
Dielectric voltage≥ 2 kVAC (rms) Rated impulse withstand volt. 4 kV (1.2/50 µs)
M23:208 to 240 VAC ± 15%,
45 to 65 Hz
M40:380 to 415 VAC ± 15%,
45 to 65 Hz
Rated operational power 5 VA @ 230 VAC, 50 Hz (M23)
≤6,5 VA @ 230 VAC, 60 Hz
(M23)
8 VA @ 400 VAC, 50 Hz (M40)
≤8,5 VA @ 400 VAC, 60 Hz
(M40)
Supplied by L2 and L3
Specifications are subject to change without notice (02.05.11)1

Datasheet - PDF

Title:Language:Size:Type:
pdf1-mostradoSelected parameters OUTPUT SIGNAL 1 relay SETPOINTS 1, fixed MONITORED VARIABLE 3-phas - CARLO GAEnglish123 Kbytespdf1-mostradoSelected parameters OUTPUT SIGNAL 1 relay SETPOINTS 1, fixed MONITORED VARIABLE 3-phas - CARLO GA
pdf1-Selected parameters OUTPUT SIGNAL 1 relay SETPOINTS 1, fixed MONITORED VARIABLE 3-phas - CARLO English12 Mbytespdf1-mostradoSelected parameters OUTPUT SIGNAL 1 relay SETPOINTS 1, fixed MONITORED VARIABLE 3-phas - CARLO GA

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review