EM24DINAV23XO2PFA CARLO GAVAZZI Selected parameters FUNCTION MID Energy analyzer MOUNTING DIN Rail POWER SU.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

EM24DINAV23XO2PFA CARLO GAVAZZI Selected parameters FUNCTION MID Energy analyzer MOUNTING DIN Rail POWER SU..

EM24DINAV23XO2PFA

CARLO GAVAZZI

Selected parameters FUNCTION MID Energy analyzer MOUNTING DIN Rail POWER SUPPLY Self power supply OUTPUT DIGITAL INPUT DC output (Open Collector) INPUT TYPE 3-phase AC CONNECTION Direct COMMUNICATION None Others RANGE 196V to 460VLL 10(65)A DISPLAY 7+1 DGT VARIABLES kWh, kvarh, VLL, VLN, Admd max, VA, VAdmd, VAdmd max, W, Wdmd, Wdmd max, var, PF, Hz, Phase-sequence DIGITAL INPUTS none PULSE 2 ALARMS none ANALOGUE none

More details


Inductive Sensors Proximity Switches

Sensors

Inductive Sensors and Loop Detector

* Brand new product in its original packaging covered by the warranties and certifications provided by CARLO GAVAZZI

* This article is obsolete. Please ask us for a quotation and we will check if there are units available or we will offer you an alternative product.

Related products

More info



Energy Management Energy Analyzer Type EM24 DIN
• RS485 serial output (MODBUS-RTU), iFIX SCADA com- patibility
• M-bus communication port (option M1)
• Dupline communication capability (option DP)
• Application adaptable display and programming proce- dure (Easyprog function)
• Easy connections management
• Certified according to MID Directive (option PF):
see “how to order” below
• Other versions available (not certified, option X):
see “how to order” on the next page
• Class 1 (kWh) according to EN62053-21
• Class B (kWh) according to EN50470-3
• Class 2 (kvarh) according to EN62053-23
• Accuracy ±0.5 RDG (current/voltage)
• Energy analyzer
• Instantaneous variables readout: 4 DGT
• Energies/gas/water readout: 8 DGT
• System variables: VLL, VLN, Admd max, VA, VAdmd, VAd- md max, W, Wdmd, Wdmd max, var, PF, Hz, Phase- sequence.
• Single phase variables: VLL, VLN, A, VA, W, var, PF
• Energy measurements: total and partial kWh and kvarh or based on 4 different tariffs single phase measurements
• Gas, cold water, hot water, kWh remote heating mea- surements
• Hour counter (6+2 DGT)
• TRMS measurements of distorted sine waves (volt- ages/currents)
• Self power supply (AV2-AV9 inputs)
• Auxiliary power supply (AV5-AV6 inputs)
• 3 digital inputs for tariff selection, DMD synch or gas/
water (hot-cold) and remote heating metering (on request)
• 2 digital outputs for pulses or for alarms or as a mix of them
• Dimensions: 4-DIN modules
• Protection degree (front): IP50
Product Description
Three-phase energy analyzer with built-in configuration joystickandLCD datadis- playing particularly indicat- ed for active and reactive energy metering and for cost allocation. Housing for DIN-
rail mountingwithIP50 (front) protection degree. Direct connection up to 65A and by means of external current and potential trans- formers.
Moreover the meter can be
provided with digital outputs that can be either for pulse proportional to the active (imported and exported) and reactive energy beingmea- sured or foralarm outputs. In alternative the RS485
communication port and 3 digital inputs or Dupline port and 3 digitalinputsor the M-bus communication port are available as an option.
Specifications are subject to change without notice EM24 DIN DS260315 1

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Últimas Opiniones de Nuestros Clientes

Todas las valoraciones que recibimos de los artículos que ofrecemos son reales y están verificadas. Un pequeño gesto, pero de mucho valor. Por eso, te agradecemos ese minuto que inviertes en dejarnos tu opinión y calificación sobre los productos, porque nos ayuda a seguir mejorando y a ofrecerte un servicio de todavía mayor calidad.