A82-2025 A822025 CARLO GAVAZZI MOUNTING Panel HOUSING Solid-core INPUT RANGE 25 A View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

A82-2025 A822025 CARLO GAVAZZI MOUNTING Panel HOUSING Solid-core INPUT RANGE 25 A

A82-2025

A822025

CARLO GAVAZZI

Available

Ship on today

MOUNTING Panel HOUSING Solid-core INPUT RANGE 25 A

More details


Energy Meters Control Analizers

Controls

Monitoring Relays and Measurement Current Transformers

* Brand new produt in its original packing covered by the warranties and certifications provided by CARLO GAVAZZI

QuantityPrice
1+169,53 €
2+165,30 €
3+163,20 €
4+161,86 €
5+161,69 €
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Monitoring Relays
True RMS AC Current Transformer
Types A 82-10, A 82-20, A 82-30
• 5 types of input:
• Output:
0 - 25 AAC
0 - 50 AAC
0 - 100 AAC
0 - 250 AAC
0 - 500 AAC
A 82-10: 0 - 20 mADC (source) A 82-20: 4 - 20 mADC (sink)
A 82-30: 0 - 10 VDC
• Easy interface to PLC or setpoint relays
Product Description
Ordering Key
A 82-10 50
True RMSACcurrentme- tering transformer for 25, 50,
100, 250 or 500 AAC. Out- put current in accordance with IEC 60381-1 (A 82-10, A 82-20) or output voltage in accordance with IEC 60381-2 (A 82-30).
A 82-10 and A 82-20 can be used with relays DIB01, PIB01, DIC01 or PIC01.
A 82-30canbeusedwith DUB01, PUB01, DUB71, DUC01 or PUC01.
All units can be directly con- nected to a PLC. Power supply ON is indicated by a green LED on the side of the housing.
Type
Output
Input current
Type Selection
Input currentOutput Type no.
25 AAC0 - 20 mA A 82-10 25
50 AAC0 - 20 mA A 82-10 50
100 AAC0 - 20 mA A 82-10 100
250 AAC0 - 20 mA A 82-10 250
500 AAC0 - 20 mA A 82-10 500
25 AAC4 - 20 mA A 82-20 25
50 AAC4 - 20 mA A 82-20 50
100 AAC4 - 20 mA A 82-20 100
250 AAC4 - 20 mA A 82-20 250
500 AAC4 - 20 mA A 82-20 500
25 AAC0 - 10 VA 82-30 25
50 AAC0 - 10 VA 82-30 50
100 AAC0 - 10 VA 82-30 100
250 AAC0 - 10 VA 82-30 250
500 AAC0 - 10 VA 82-30 500
InputSpecifications
A 82-10/20/30 25A 82-10/20/30 50A 82-10/20/30 100 A 82-10/20/30 250 A 82-10/20/30 500
Current range 0 - 25 AAC 0 - 50 AAC0 - 100 AAC0 - 250 AAC0 - 500 AAC Max. current (continuously)600 AAC 600 AAC 600 AAC 600 AAC 600 AAC Max. overload current (t = 30 s) 3000 AAC 3000 AAC 3000 AAC 3000 AAC 3000 AAC Rated insulation voltage
Input - output1000 VAC rms 1000 VAC rms 1000 VAC rms 1000 VAC rms 1000 VAC rms
Overvoltage categoryIV (IEC 60664) IV (IEC 60664)IV (IEC 60664) IV (IEC 60664) IV (IEC 60664)
Dielectric strength
Dielectric voltage 6 kVAC rms6 kVAC rms 6 kVAC rms6 kVAC rms6 kVAC rms
Rated impulse withstand volt.12 kV12 kV12 kV12 kV12 kV
(1.2/50 µs)(1.2/50 µs)(1.2/50 µs)(1.2/50 µs)(1.2/50 µs)
Specifications are subject to change without notice (10.07.08)1

Datasheet - PDF

Title:Language:Size:Type:
pdf1-mostrado MOUNTING Panel HOUSING Solid-core INPUT RANGE 25 A - CARLO GAVAZZI - A82-2025 - A822025 English158 Kbytespdf1-mostrado MOUNTING Panel HOUSING Solid-core INPUT RANGE 25 A - CARLO GAVAZZI - A82-2025 - A822025
pdf1- MOUNTING Panel HOUSING Solid-core INPUT RANGE 25 A - CARLO GAVAZZI - A82-2025 - A822025 English12 Mbytespdf1-mostrado MOUNTING Panel HOUSING Solid-core INPUT RANGE 25 A - CARLO GAVAZZI - A82-2025 - A822025

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review