Product successfully added to your shopping cart
2TLA020052R1000
ABB
1
Relays > Device for monitoring of safety-related circuits
Fences and rolling doors > Dynamic security - Vital
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Product Main Type | Vital |
| Product Name | Safety controller |
| Function | Safety controller for monitoring of safety devices using DYNlink |
| Sub-Function | Start/test input, Manual/Auto reset |
| Popular Downloads | |
| Data Sheet, Technical Information | 2TLC010001C0202 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Marketing Video | 2TLC010018N0201 |
| Installation | |
| Instructions and Manuals | 2TLC172156M0201 |
| Dimensions | |
| Product Net Depth / Length | 120 mm |
| Product Net Height | 84 mm |
| Product Net Width | 22.5 mm |
| Product Net Weight | 0.267 kg |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Safety Information | |
| Certification Agency | CE |
| TÜV NORD | |
| CCC | |
| UKCA | |
| cCSAus | |
| Performance Level (PL) | Up to e |
| Safety Integrity Level (SIL) | 3 |
| Technical | |
| Number of Outputs | Failsafe (Relay) 2 |
| Rated Control Supply Voltage (Us) | 24 V DC |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2022-006480 |
| RoHS Declaration | 2CMT2022-006499 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act - TSCA | 2CMT2023-006522 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| Certificates and Declarations | |
| CQC Certificate | CQC2013010303610941 |
| CSA Certificate | 2TLC172045D0201 |
| Declaration of Conformity - CCC | 2020980303000243 |
| Declaration of Conformity - CE | 2TLC172025D0201 |
| Declaration of Conformity - UKCA | 2TLC010206D0201 |
| TÜV Certificate | 2TLC172031D0401 |
| UL Certificate | 2TLC172045D0201 |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 90 mm |
| Package Level 1 Depth / Length | 45 mm |
| Package Level 1 Height | 130 mm |
| Package Level 1 Gross Weight | 0.367 kg |
| Package Level 1 EAN | 7350024431810 |
| External Classifications and Standards | |
| eClass | V11.0 : 27371819 |
| ETIM 7 | EC001449 - Device for monitoring of safety-related circuits |
| ETIM 8 | EC001449 - Device for monitoring of safety-related circuits |
| ETIM 9 | EC001449 - Device for monitoring of safety-related circuits |
| IDEA Granular Category Code (IGCC) | 3584 >> Safety Control Module |
| UNSPSC | 32151802 |
| Object Classification Code | K |
| E-Number (Finland) | 2712238 |
| E-Number (Sweden) | 3858760 |
| Feature Name | Feature Value |
|---|---|
| Model (EF000010) | Other |
| Suitable for monitoring of position switches (EF007270) | Yes |
| Suitable for monitoring of emergency-stop circuits (EF007268) | Yes |
| Suitable for monitoring of valves (EF007272) | Yes |
| Suitable for monitoring of optoelectronic protection equipment (EF007269) | Yes |
| Suitable for monitoring of tactile sensors (EF007271) | No |
| Suitable for monitoring of magnetic switches (EF007266) | Yes |
| Suitable for monitoring of proximity switches (EF007267) | Yes |
| Type of electric connection (EF003961) | Screw connection |
| Suitable for rail mounting (EF003972) | Yes |
| With detachable clamps (EF003340) | Yes |
| Evaluation inputs (EF008245) | 1-channel |
| With start input (EF003342) | Yes |
| With muting function (EF004057) | No |
| With feedback circuit (EF003343) | Yes |
| Release-delay (EF001129) | 48 s |
| Number of outputs, safety related, undelayed, with contact (EF003344) | 2 |
| Number of outputs, safety related, delayed, with contact (EF003345) | 0 |
| Number of outputs, safety related, undelayed, semiconductors (EF003346) | 0 |
| Number of outputs, safety related, delayed, semiconductors (EF003347) | 0 |
| Number of outputs, signalling function, undelayed, with contact (EF003348) | 0 |
| Number of outputs, signalling function, delayed, with contact (EF003349) | 0 |
| Number of outputs, signalling function, undelayed, semiconductors (EF003350) | 0 |
| Number of outputs, signalling function, delayed, semiconductors (EF003351) | 0 |
| Type of safety according to IEC 61496-1 (EF004105) | 4 |
| Stop category according to IEC 60204 (EF007498) | 0 |
| Performance level according to EN ISO 13849-1 (EF007399) | Level e |
| SIL according to IEC 61508 (EF009889) | 3 |
| With approval for BG BIA (EF004145) | No |
| With approval according to UL (EF001783) | No |
| Width (EF000008) | 22.5 mm |
| Height (EF000040) | 84 mm |
| Depth (EF000049) | 120 mm |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG SAFETY EN.pdf | 42 Mbytes |
|
| Vital 1 Safety Controller - ABB - Vital 1 - 2TLA020052R1000 | 80 Kbytes |
![]() |
| Vital 1 2TLA020052R1000 ABB Vital 1 Safety Controller | 60 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.