Product successfully added to your shopping cart
GJL1211901R8014
ABB
1
VB6-30-01-84 Mini Reversing Contactor
VB6-30-01 MINI INVERTER 110V-50/60 TOR
VB6-30-01-84 Mini Reversing Contactor 110 ... 127 V AC - 3 NO - 0 NC - Screw Terminals
Low-voltage industrial components > Combination of contactors
Contactors and overload relays > Minicontactors B6-B7
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85365080 |
| Popular Downloads | |
| EPLAN Data | 9AAC205198_EPLAN |
| Data Sheet, Technical Information | 1SBC100214C0202 |
| Instructions and Manuals | 2CDC102046M6801 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Dimensions | |
| Product Net Width | 96.2 mm |
| Product Net Depth / Length | 46.7 mm |
| Product Net Height | 57.5 mm |
| Product Net Weight | 0.355 kg |
| Dimension Diagram | GJL1200447F0001 |
| Technical | |
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Poles | 3P |
| Standards | IEC/EN 60947-1 |
| IEC/EN 60947-4-1 | |
| IEC/EN 60947-5-1 | |
| UL 60947-1 | |
| UL 60947-4-1 | |
| IEC 60335-2-40 A2L | |
| Rated Operational Voltage | Auxiliary Circuit 690 V AC |
| Auxiliary Circuit 250 V DC | |
| Main Circuit 690 V AC | |
| Main Circuit 220 V DC | |
| Rated Frequency (f) | Control Circuit 400 Hz |
| Control Circuit 50 Hz | |
| Control Circuit 60 Hz | |
| Main Circuit 60 Hz | |
| Main Circuit 50 Hz | |
| Main Circuit DC | |
| Conventional Free-air Thermal Current (Ith) | Main Circuit 20 A |
| Rated Operational Current AC-1 (Ie) | (220 / 240 V) 40 °C 20 A |
| (220 / 240 V) 55 °C 16 A | |
| (380 / 440 V) 40 °C 20 A | |
| (380 / 440 V) 55 °C 16 A | |
| (690 V) 40 °C 6 A | |
| (690 V) 55 °C 6 A | |
| Rated Operational Current AC-3 (Ie) | (230 V) 55°C 9 A |
| (400 V) 55 °C 9 A | |
| (500 V) 55 °C 6.5 A | |
| (690 V) NO 55°C 3.5 A | |
| Rated Operational Current AC-15 (Ie) | (440 V AC) 3 A |
| (24 V) 4 A | |
| (120 V) 4 A | |
| (240 V) 4 A | |
| (500 V) 2 A | |
| (380 / 400 V) 3 A | |
| Rated Operational Current DC-13 (Ie) | (24 V) 2.5 A |
| (110 V) 0.7 A | |
| (220 / 240 V) 0.4 A | |
| Rated Operational Power AC-3 (Pe) | (230 V) Three Phase 2.2 kW |
| (400 V) Three Phase 4 kW | |
| (500 V) Three Phase 4 kW | |
| (690 V) Three Phase, NO 3 kW | |
| Rated Breaking Capacity AC-3 | 8 x Ie / AC-3 |
| Rated Making Capacity AC-3 | 10 x Ie / AC-3 |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 64 A |
| Rated Insulation Voltage (Ui) | 690 V |
| acc. to UL/CSA 600 V | |
| Rated Impulse Withstand Voltage (Uimp) | Main Circuit 6 kV |
| Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour |
| (AC-15) 600 cycles per hour | |
| (AC-3) 600 cycles per hour | |
| (DC-1) 600 cycles per hour | |
| (DC-13) 600 cycles per hour | |
| (DC-3) 600 cycles per hour | |
| Mechanical Durability | Nr. Operations 10000000 cycle |
| Minimum Switching Capacity | Auxiliary Circuit 17 V |
| Auxiliary Circuit 5 mA | |
| Coil Operating Limits | (acc. to IEC 60947-4-1) for AC supply 0.85 ... 1.1 x Uc (at θ ≤ 55 °C) |
| (acc. to IEC 60947-4-1) for DC supply 0.85 ... 1.1 x Uc (at θ ≤ 55 °C) | |
| Rated Control Circuit Voltage (Uc) | 110 ... 127 V AC |
| Coil Consumption | Average Holding Value 50 Hz 3.5 V·A |
| Average Pull-in Value 50 Hz 3.5 V·A | |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 1 W |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 1 ... 2.5 mm² |
| Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm² | |
| Flexible 1/2x 1 ... 2.5 mm² | |
| Rigid 1/2x 1 ... 4 mm² | |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1/2x 1 ... 2.5 mm² |
| Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm² | |
| Flexible 1/2x 1 ... 2.5 mm² | |
| Rigid 1/2x 1 ... 4 mm² | |
| Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 1 ... 2.5 mm² |
| Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm² | |
| Flexible 1/2x 1 ... 2.5 mm² | |
| Rigid 1/2x 1 ... 4 mm² | |
| Wire Stripping Length | Auxiliary Circuit 9 mm |
| Main Circuit 9 mm | |
| Degree of Protection | Auxiliary Circuit Terminals IP20 |
| Control Circuit Terminals IP20 | |
| Main Circuit Terminals IP20 | |
| Recommended Screw Driver | M3 |
| Pozidriv 1 | |
| Tightening Torque | Control Circuit 0.8 ... 1.1 N·m |
| Main Circuit 0.8 ... 1.1 N·m | |
| Terminal Type | Screw Terminals |
| Product Name | Mini Reversing Contactor |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V AC |
| General Use Rating UL/CSA | (300 V AC) 12 A |
| Horsepower Rating UL/CSA | (115 V AC) Single Phase 0.25 Hp |
| (200 V AC) Three Phase 1 Hp | |
| (220 ... 240 V AC) Three Phase 2 Hp | |
| (230 V AC) Single Phase 0.5 Hp | |
| (440 ... 480 V AC) Three Phase 3 Hp | |
| (550 ... 600 V AC) Three Phase 1 Hp | |
| Connecting Capacity Main Circuit UL/CSA | Stranded 1/2x 22-10 AWG |
| Connecting Capacity Auxiliary Circuit UL/CSA | Stranded 1/2x 22-10 AWG |
| Contact Rating UL/CSA | A600 |
| Tightening Torque UL/CSA | Auxiliary Circuit 7 in·lb |
| Control Circuit 7 in·lb | |
| Main Circuit 7 in·lb | |
| Full Load Amps Motor Use | (115 V AC) Single Phase 5.8 A |
| (200 V AC) Three Phase 4.8 A | |
| (220 ... 240 V AC) Three Phase 6.8 A | |
| (230 V AC) Single Phase 4.9 A | |
| (440 ... 480 V AC) Three Phase 4.8 A | |
| (550 ... 600 V AC) Three Phase 1.7 A | |
| Environmental | |
| Ambient Air Temperature | Operation -20 ... +55 °C |
| Storage -40 ... +80 °C | |
| Maximum Operating Altitude Permissible | 2000 m |
| Resistance to Shock acc. to IEC 60068-2-27 | 11 ms Pulse 15g |
| Resistance to Vibrations | 5g 5 ... 150 Hz |
| Pollution Degree | 3 |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2021-006202 |
| RoHS Declaration | 2CMT2021-006277 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act - TSCA | 2CMT2023-006525 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| ABB EcoSolutions | |
| End Of Life Disassembling Instructions | 1SBC100156C0269 |
| Environmental Product Declaration - EPD | 1SAC200410H0001 |
| Certificates and Declarations | |
| A2L Certificate – IEC | 1SAA938000-4601 |
| CB Certificate | 1SAA938000-2002 |
| CQC Certificate | CQC2003010304064033 |
| Declaration of Conformity - CCC | 2020980304001854 |
| Declaration of Conformity - CE | 1SAD101100-3101 |
| Declaration of Conformity - UKCA | 1SAD201100-3101 |
| DNV GL Certificate | 1SAA938000-0306 |
| EAC Certificate | 1SAA920000-2702 |
| KC Certificate | 1SAA938000-1501 |
| RMRS Certificate | 1SAA938000-0704 |
| UL Certificate | E191658-19881208 |
| Container Information | |
| Package Level 1 Units | box 5 piece |
| Package Level 1 Width | 115 mm |
| Package Level 1 Depth / Length | 280 mm |
| Package Level 1 Height | 54 mm |
| Package Level 1 Gross Weight | 1.845 kg |
| Package Level 1 EAN | 4013614413766 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| ETIM 7 | EC000010 - Combination of contactors |
| ETIM 8 | EC000010 - Combination of contactors |
| ETIM 9 | EC000010 - Combination of contactors |
| eClass | V11.0 : 27371009 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4761 >> Magnet contactor, AC-switching |
| Feature Name | Feature Value |
|---|---|
| Function (EF000030) | Reversing safety |
| Rated control supply voltage AC 50 Hz (EF003978) | 110 V |
| Rated control supply voltage AC 60 Hz (EF003979) | 110 V |
| Voltage type for actuating (EF008242) | AC |
| Rated operation current Ie at AC-1, 400 V (EF001393) | 6 A |
| Rated operation current Ie at AC-3, 400 V (EF001392) | 9 A |
| Rated operation power at AC-3, 400 V (EF001364) | 4 kW |
| Rated operation power NEMA (EF011960) | 1.4914 kW |
| Number of normally closed contacts as main contact (EF001375) | 0 |
| Number of normally open contacts as main contact (EF001374) | 3 |
| Type of electrical connection for auxiliary- and control current circuit (EF006979) | Screw connection |
| Type of electrical connection of main circuit (EF006819) | Screw connection |
| Degree of protection (IP) (EF005474) | IP20 |
| Degree of protection (NEMA) (EF011959) | 1 |
| Suitable for rail mounting (EF003972) | Yes |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE MOTOR PROTECTION EN.pdf | 240 Mbytes |
|
| VB6-30-01-84 Mini Reversing Contactor - ABB - VB6-30-01 - GJL1211901R8014 | 100 Kbytes |
![]() |
| VB6-30-01 GJL1211901R8014 ABB VB6-30-01-84 Mini Reversing Contactor | 88 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.