Product successfully added to your shopping cart
GJH1213061R6402
ABB
1
TKC6-40E-62 Mini Contactor Relay 77-143VDC
TKC6-40E MINICONT. AUX. 77-143Vdc
TKC6-40E-62Mini Contactor Relay77 ... 143 V DC4NO0NCScrew Terminals
Low-voltage industrial components > Contactor relay
Contactors and overload relays > Minicontactors B6-B7
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85365080 |
| Popular Downloads | |
| EPLAN Data | 9AAC205064_EPLAN |
| Data Sheet, Technical Information | 1SBC100214C0202 |
| Instructions and Manuals | 2CDC102001C0202 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Dimensions | |
| Product Net Width | 52.5 mm |
| Product Net Depth / Length | 46.5 mm |
| Product Net Height | 57.5 mm |
| Product Net Weight | 0.18 kg |
| Technical | |
| Number of Main Contacts NO | 0 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 4 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 4P |
| Standards | IEC/EN 60947-1 |
| IEC/EN 60947-4-1 | |
| IEC/EN 60947-5-1 | |
| Rated Operational Voltage | Auxiliary Circuit 690 V AC |
| Auxiliary Circuit 250 V DC | |
| Rated Frequency (f) | Auxiliary Circuit 50 Hz |
| Auxiliary Circuit 60 Hz | |
| Auxiliary Circuit DC | |
| Control Circuit DC | |
| Main Circuit 60 Hz | |
| Main Circuit 50 Hz | |
| Main Circuit DC | |
| Conventional Free-air Thermal Current (Ith) | Auxiliary Circuit 6 A |
| Rated Operational Current AC-15 (Ie) | (24 V) 4 A |
| (120 V) 4 A | |
| (240 V) 4 A | |
| (400 V) 3 A | |
| (500 V) 2 A | |
| Rated Operational Current DC-13 (Ie) | (24 V) 2.5 A |
| (110 V) 0.7 A | |
| (220 / 240 V) 0.4 A | |
| Short-Circuit Protective Devices | gG Type Fuses 6 A |
| Rated Insulation Voltage (Ui) | 690 V |
| Rated Impulse Withstand Voltage (Uimp) | Auxiliary Circuit 6 kV |
| Maximum Electrical Switching Frequency | (AC-15) 600 cycles per hour |
| (DC-13) 600 cycles per hour | |
| Mechanical Durability | Nr. Operations 10000000 cycle |
| Minimum Switching Capacity | 17 V |
| 5 mA | |
| Coil Operating Limits | (acc. to IEC 60947-5-1) for DC supply Uc Min. ... Uc Max. (at θ ≤ 55 °C) |
| Rated Control Circuit Voltage (Uc) | 77 ... 143 V DC |
| Coil Consumption | Average Holding Value DC 5 W |
| Average Pull-in Value DC 5 W | |
| Power Loss | at Rated Operating Conditions per Pole 0.32 W |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1/2x 1 ... 2.5 mm² |
| Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm² | |
| Flexible 1/2x 1 ... 2.5 mm² | |
| Rigid 1/2x 1 ... 4 mm² | |
| Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 1 ... 2.5 mm² |
| Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm² | |
| Flexible 1/2x 1 ... 2.5 mm² | |
| Rigid 1/2x 1 ... 4 mm² | |
| Wire Stripping Length | Auxiliary Circuit 9 mm |
| Degree of Protection | Auxiliary Circuit Terminals IP20 |
| Control Circuit Terminals IP20 | |
| Recommended Screw Driver | M3 |
| Pozidriv 1 | |
| Tightening Torque | Auxiliary Circuit 0.8 ... 1.1 N·m |
| Control Circuit 0.8 ... 1.1 N·m | |
| Main Circuit 0.8 ... 1.1 N·m | |
| Terminal Type | Screw Terminals |
| Mini Contactor Type | Mini Contactor Relay |
| Product Name | Mini Contactor Relay |
| Remarks | No CA6 or CAF6 mountable |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | Auxiliary Circuit 600 V AC/DC |
| General Use Rating UL/CSA | (600 V AC) 5 A |
| Environmental | |
| Ambient Air Temperature | Operation -30 ... +70 °C |
| Storage -40 ... +85 °C | |
| Maximum Operating Altitude Permissible | 2000 m |
| Resistance to Shock acc. to IEC 60068-2-27 | 11 ms Pulse 15g |
| Resistance to Vibrations | 3g 3 ... 150 Hz |
| Shock and Vibration Withstand acc. to IEC 61373 | Category 1, Class B |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2021-006202 |
| RoHS Declaration | 2CMT2021-006277 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act - TSCA | 2CMT2023-006525 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| ABB EcoSolutions | |
| End Of Life Disassembling Instructions | 1SBC100156C0269 |
| Environmental Product Declaration - EPD | 1SAC200409H0001 |
| Certificates and Declarations | |
| Declaration of Conformity - CE | 1SAD101100-3101 |
| Declaration of Conformity - UKCA | 1SAD201100-3101 |
| EAC Certificate | 1SAA938001-2701 |
| Container Information | |
| Package Level 1 Units | box 10 piece |
| Package Level 1 Width | 115 mm |
| Package Level 1 Depth / Length | 280 mm |
| Package Level 1 Height | 54 mm |
| Package Level 1 Gross Weight | 1.87 kg |
| Package Level 1 EAN | 4013614412004 |
| External Classifications and Standards | |
| Object Classification Code | K |
| ETIM 7 | EC000196 - Contactor relay |
| ETIM 8 | EC000196 - Contactor relay |
| ETIM 9 | EC000196 - Contactor relay |
| eClass | V11.0 : 27371001 |
| UNSPSC | 39121500 |
| Feature Name | Feature Value |
|---|---|
| Rated control supply voltage DC (EF003980) | 143 V |
| Voltage type for actuating (EF008242) | DC |
| Rated operation current Ie, 400 V (EF001378) | 3 A |
| Connection type auxiliary circuit (EF006820) | Screw connection |
| Mounting method (EF000003) | DIN rail |
| Interface (EF000594) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 4 |
| Number of auxiliary contacts as normally closed contact, delayed switching (EF007281) | 0 |
| Number of auxiliary contacts as normally open contact, leading (EF007282) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 0 |
| With LED indication (EF005950) | No |
| Suitable for manual operation (EF002978) | No |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE MOTOR PROTECTION EN.pdf | 240 Mbytes |
|
| TKC6-40E-62 Mini Contactor Relay 77-143VDC - ABB - TKC6-40E - GJH1213061R6402 | 96 Kbytes |
![]() |
| TKC6-40E GJH1213061R6402 ABB TKC6-40E-62 Mini Contactor Relay 77-143VDC | 80 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.