ANUNCIAR
1SAZ911201R1005 ABB TF96-87 Thermal Overload Relay View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

1SAZ911201R1005 ABB TF96-87 Thermal Overload Relay

1SAZ911201R1005

ABB

TF96-87 Thermal Overload Relay

TF96-87 THERMAL OVERLOAD RELAY 75-87A

TF96-87 Thermal Overload Relay 75 ... 87 A

More details


Low-voltage industrial components > Thermal overload relay

Contactors and overload relays > Thermal Relays

Brand new product in its original packaging covered by the warranties and certifications provided by ABB

Total: $163.18
Unit price: $163.18
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

Best sellers

More info



Ordering
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Popular Downloads
Data Sheet, Technical Information2CDC106069D0201
Instructions and Manuals2CDC106052M6803
Instructions and Manuals (Part 2)1SAC200017M0002
Ex Operating Instructions2CDC106086M6801
Time-Current Characteristic Curve1SAZ900502F0005
CAD Dimensional Drawing2CDC001079B0201
Dimension Diagram1SAZ900401F0001
Dimensions
Product Net Width69.9 mm
Product Net Height106.9 mm
Product Net Depth / Length106.3 mm
Product Net Weight0.52 kg
Technical
Setting Range75 ... 87 A
Rated Operational VoltageAuxiliary Circuit 600 V AC/DC
Main Circuit 690 V AC
Main Circuit 440 V DC
Rated Operational Current (Ie)87 A
Rated Frequency (f)Auxiliary Circuit 50 Hz
Auxiliary Circuit 60 Hz
Auxiliary Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp)Auxiliary Circuit 6 kV
Main Circuit 8 kV
Rated Insulation Voltage (Ui)690 V
Number of Poles3P
Number of Auxiliary Contacts NC1
Number of Auxiliary Contacts NO1
Number of Protected Poles3
Conventional Free-air Thermal Current (Ith)Auxiliary Circuit NC 6 A
Auxiliary Circuit NO 4 A
Rated Operational Current AC-15 (Ie)(120 V) NC 3 A
(120 V) NO 0.5 A
(240 V) NC 3 A
(240 V) NO 0.5 A
(400 V) NC 0.75 A
(400 V) NO 0.5 A
(500 V) NC 0.75 A
(500 V) NO 0.5 A
Rated Operational Current DC-13 (Ie)(125 V) NC 0.55 A
(125 V) NO 0.55 A
(24 V) NC 1.25 A
(24 V) NO 1.25 A
(250 V) NC 0.27 A
(250 V) NO 0.27 A
(500 V) NC 0.15 A
(500 V) NO 0.15 A
(60 V) NC 0.55 A
(60 V) NO 0.55 A
Degree of ProtectionHousing IP20
Main Circuit Terminals IP10
Pollution Degree3
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Flexible 1/2x 0.75 ... 1 mm²
Flexible 1/2x 1 ... 2.5 mm²
Rigid 1/2x 0.75 ... 4 mm²
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 6 ... 35 mm²
Flexible with Ferrule 1x 6 ... 50 mm²
Flexible with Insulated Ferrule 1/2x 6 ... 16 mm²
Flexible with Insulated Ferrule 1x 6 ... 50 mm²
Flexible 1/2x 6 ... 35 mm²
Flexible 1x 6 ... 50 mm²
Rigid 1/2x 6 ... 35 mm²
Rigid 1x 6 ... 50 mm²
Tightening TorqueAuxiliary Circuit 1 ... 1.2 N·m
Main Circuit 6.0 ... 9.0 N·m
Wire Stripping LengthAuxiliary Circuit 9 mm
Main Circuit 20 mm
Recommended Screw DriverAuxiliary Circuit Pozidriv 2
Main Circuit Hexagon 4
Mounting Position1 ... 6
Power Lossat Rated Operating Conditions per Pole 2.9 ... 3.9 W
Suitable ForAF80
AF96
StandardsIEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 60947-5-1
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Technical UL/CSA
Maximum Operating Voltage UL/CSAMain Circuit 600 V AC
Contact Rating UL/CSA(NC:) B600
(NC:) Q600
(NO:) Q600
(NO:) D300
Connecting Capacity Main Circuit UL/CSAFlexible 1x 8-1 AWG
Flexible 2x 8-3 AWG
Stranded 1x 8-1 AWG
Stranded 2x 8-3 AWG
Connecting Capacity Auxiliary Circuit UL/CSAFlexible 1/2x 18-12 AWG
Stranded 1/2x 18-12 AWG
Tightening Torque UL/CSAAuxiliary Circuit 9 ... 11 in·lb
Main Circuit 53 ... 80 in·lb
Environmental
Ambient Air TemperatureOperation -40 ... +70 °C
Operation Compensated -40 ... +70 °C
Storage -50 ... +80 °C
Ambient Air Temperature CompensationYes
Maximum Operating Altitude Permissible2000 m
Resistance to Shock acc. to IEC 60068-2-2711 ms Pulse 25g
Resistance to Vibrations5g 3 ... 150 Hz
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA2CMT2023-006525
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration2CMT2021-006202
RoHS Declaration2CMT2021-006277
WEEE B2C / B2BBusiness To Business
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetUL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions1SAC200334H0001
Environmental Information1SAC200059H0009
Environmental Product Declaration - EPD1SAC200249H0001
Certificates and Declarations
A2L Certificate – IEC1SAA941000-4601
ABS Certificate1SAA941003-0101
ATEX Certificate1SAA941006-3901
BV Certificate1SAA941001-0203
CB Certificate1SAA941015-2001
CCC Certificate2024010304636179
CQC CertificateCQC2014010309689434
Declaration of Conformity - CCC2020980309000292
Declaration of Conformity - CE1SAD101100-3503
Declaration of Conformity - UKCA1SAD201100-3503
DNV GL Certificate1SAA941004-0301
EAC Certificate1SAA941002-2701
IECEx Certificate1SAA941002-4001
LR Certificate1SAA941003-0501
RINA CertificateRINA_ELE098115XG
RMRS Certificate1SAA941002-0701
UL CertificateE48139-20130329
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width97 mm
Package Level 1 Height121 mm
Package Level 1 Depth / Length97 mm
Package Level 1 Gross Weight0.62 kg
Package Level 1 EAN4013614483028
Package Level 2 Units12 piece
Package Level 2 Width280 mm
Package Level 2 Height210 mm
Package Level 2 Depth / Length395 mm
Package Level 2 Gross Weight7.826 kg
Package Level 2 EAN4013614485466
External Classifications and Standards
Object Classification CodeF
ETIM 9EC000106 - Thermal overload relay
ETIM 10EC000106 - Thermal overload relay
eClassV11.0 : 27371501
UNSPSC39122330
IDEA Granular Category Code (IGCC)5366 >> Thermal overload relay
E-Number (Finland)3706594
E-Number (Norway)4116798
E-Number (Sweden)3210274

ETIM for 1SAZ911201R1005 Low-voltage industrial controls and switchgear (EC000106)
Feature Name Feature Value
Adjustable current range (EF008211) 75 A
Max. rated operation voltage Ue (EF007357) 690 V
Mounting method (EF000003) Direct attachment
Type of electrical connection of main circuit (EF006819) Screw connection
Number of auxiliary contacts as normally closed contact (EF001377) 1
Number of auxiliary contacts as normally open contact (EF001376) 1
Number of auxiliary contacts as change-over contact (EF003531) 1
Release class (EF006668) CLASS 10
Reset function input (EF011940) No
Reset function automatic (EF011941) Yes
Reset function push-button (EF011942) Yes

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.