ABB 1SFA898103R7000 1SFA898103R7000 - Image 1

Images are for illustrative purposes only. Please refer to data sheet for details.

1SFA898103R7000 ABB Soft Starter 400V/15kW, 500V/18,5kW, 30A

Reference: 1SFA898103R7000

Manufacturer: ABB

Description:

Soft Starter 400V/15kW, 500V/18,5kW, 30A
PSTX30-600-70 SOFT STARTER
PSTX30-600-70 Softstarter - 30 A - 208 ... 600 V AC

Categories:

  • Low-voltage industrial components > Soft starter
  • ABB > Soft Starters > Soft starters PSTX

Brand new product in its original packaging covered by the warranties and certifications provided by ABB

  • More Info
  • ETIM
  • PDF
  • Reviews
Guarantee, repair and return.

Unit Price: 688,86 €

This price is per unit and is the net value (not including taxes if applicable).

Calculate price by quantity

QuantityPrice

Standard lead time: 7-8 days.

  • These delivery times are an estimate any may vary when the item order has been processed.

LAST VIEWED

MORE INFO

Ordering
Minimum Order Quantity1 piece
Customs Tariff Number85371091
Popular Downloads
Data Sheet, Technical Information1SFC132012C0201
Instructions and Manuals1SFC132428M0201
Instructions and Manuals (Part 2)1SFC132081M0201
Instructions and Manuals (Part 3)1SFC132060M0201
CAD Dimensional Drawing2CDC001079B0201
Wiring DiagramN/A
Dimensions
Product Net Width150 mm
Product Net Height314 mm
Product Net Depth / Length198 mm
Product Net Weight4.6 kg
Technical
Rated Operational Voltage208 ... 600 V AC
Rated Control Supply Voltage (Us)100 ... 250 V AC
Rated Control Circuit Voltage (Uc)24 V DC
Rated Frequency (f)50/60 Hz
Main Circuit 50 / 60 Hz
Rated Operational Power - In-Line Connection (Pe)(230 V) 7.5 kW
(400 V) 15 kW
(500 V) 18.5 kW
Rated Operational Current - In-Line Connection (Ie)30 A
Rated Operational Power - Inside Delta Connectionat 230 V 12.5 kW
at 400 V 25 kW
at 500 V 30 kW
Rated Operational Current - Inside Delta Connection52 A
Service Factor Percentage100 %
Overload ProtectionBuilt-in electronic overload protection
Integrated Electronic OverloadYes
Starting Capacity at Maximum Rated Current Ie4xIe for 10s
Ramp Time1 ... 120 second [unit of time]
Initial Voltage During Start10 ... 99 %
Step Down Voltage Special Ramp100 ... 10 %
Current Limit Function1.5 ... 7.5 xle
Switch for Inside Delta ConnectionYes
Run Signal RelayYes
By-pass Signal RelayYes
Fault Signal RelayYes
Overload Signal RelayYes
Analog Outputs0…10 V, 0…20 mA, 4…20 mA
Signal Indication Ready to Start/Standby ON (LED)Green
Signal Indication Running R (LED)Green
Signal Indication Protection (LED)Yellow
Signal Indication Fault (LED)Red
CommunicationModbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal TypeCable Clamp
Connecting Capacity Main CircuitHole Diameter 8.5 mm
Connecting Capacity Control CircuitRigid 1 x 2.5 mm²
Connecting Capacity Supply CircuitRigid 1 x 2.5
Tightening TorqueMain Circuit 8 N·m
Product Main TypePSTX30
FunctionAuto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Full voltage start
Jog with slow speed, forward and reverse
Keypad password
Kick start
Limp mode with two-phase motor control if one set of thyristors is shorted
Motor heating
Pre-start function
Pump cleaning
Real time clock
Sequence start
Soft start with torque control
Soft start with voltage ramp
Soft stop with torque control
Soft stop with voltage ramp
Stand still brake
Start reverse (external contactors)
Thyristor runtime measurement
Torque limit
Voltage sags detection
Protection FunctionBypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Warning DetailsCurrent imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
Technical UL/CSA
Horsepower Rating UL/CSA(200 ... 208 V AC) Three Phase 7.5 Hp
(220 ... 240 V AC) Three Phase 10 Hp
(440 ... 480 V AC) Three Phase 20 Hp
(550 ... 600 V AC) Three Phase 25 Hp
Maximum Operating Voltage UL/CSAMain Circuit 600 V
Tightening Torque UL/CSAMain Circuit 70.8
Environmental
Ambient Air TemperatureOperation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration2CMT2022-006481
RoHS Declaration2CMT2022-006500
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP46ee42b5-0784-4f84-a200-fba43f921301 China
Toxic Substances Control Act - TSCA2CMT2023-006524
WEEE B2C / B2BBusiness To Business
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
CQC CertificateCN: CQC2014010304744405 / SE: CQC2014010304724380
Declaration of Conformity - CCCCN: 2020980304001091 / SE: 2020980304001489
Declaration of Conformity - CE2CMT005209
DNV CertificateTAE000087N
Container Information
Package Level 1 Width200 mm
Package Level 1 Depth / Length282 mm
Package Level 1 Height388 mm
Package Level 1 Gross Weight5.6 kg
Package Level 1 EAN7320500501290
Package Level 1 Unitsbox 1 piece
External Classifications and Standards
Object Classification CodeQ
ETIM 7EC000640 - Soft starter
ETIM 8EC000640 - Soft starter
ETIM 9EC000640 - Soft starter
eClassV11.0 : 27370907
UNSPSC39121521
IDEA Granular Category Code (IGCC)4740 >> Soft starter

ETIM for 1SFA898103R7000 Low-voltage industrial controls and switchgear (EC000640)

Feature nameRated operation current Ie at 40 °C Tu (EF007039)
Feature value30 A
Feature nameRated operating voltage Ue (EF002418)
Feature value208 V
Feature nameRated power three-phase motor, inline, at 230 V (EF007053)
Feature value7.5 kW
Feature nameRated power three-phase motor, inline, at 400 V (EF007054)
Feature value15 kW
Feature nameRated power three-phase motor, inside delta, at 230 V (EF007055)
Feature value12.5 kW
Feature nameRated power three-phase motor, inside delta, at 400 V (EF007056)
Feature value25 kW
Feature nameInternal bypass (EF009214)
Feature valueYes
Feature nameWith display (EF000458)
Feature valueYes
Feature nameTorque control (EF009215)
Feature valueYes
Feature nameRated surrounding temperature without derating (EF007074)
Feature value40 °C
Feature nameRated control supply voltage AC 50 Hz (EF003978)
Feature value100 V
Feature nameRated control supply voltage AC 60 Hz (EF003979)
Feature value100 V
Feature nameVoltage type for actuating (EF008242)
Feature valueAC
Feature nameIntegrated motor overload protection (EF007297)
Feature valueYes
Feature nameRelease class (EF006668)
Feature valueAdjustable
Feature nameDegree of protection (IP) (EF005474)
Feature valueIP00
Feature nameDegree of protection (NEMA) (EF011959)
Feature value1

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.