ANUNCIAR
1SFA898210R7000 ABB Soft Starter 400V/75kW, 500V/90kW, 690V/132kW, 143A View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

1SFA898210R7000 ABB Soft Starter 400V/75kW, 500V/90kW, 690V/132kW, 143A

1SFA898210R7000

ABB

Soft Starter 400V/75kW, 500V/90kW, 690V/132kW, 143A

PSTX142-690-70 SOFT STARTER

PSTX142-690-70 Softstarter - 142 A - 208 ... 690 V AC

More details


Low-voltage industrial components > Soft starter

Soft Starters > Soft starters PSTX

Brand new product in its original packaging covered by the warranties and certifications provided by ABB

Total: $2,179.02
Unit price: $2,179.02
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Ordering
Minimum Order Quantity1 piece
Customs Tariff Number85371091
Popular Downloads
Data Sheet, Technical Information1SFC132012C0201
Instructions and Manuals1SFC132428M0201
Instructions and Manuals (Part 2)1SFC132081M0201
Instructions and Manuals (Part 3)1SFC132060M0201
CAD Dimensional Drawing2CDC001079B0201
EPLAN Data9AAC181166_EPLAN
Wiring DiagramN/A
Dimensions
Product Net Width199 mm
Product Net Height377 mm
Product Net Depth / Length283 mm
Product Net Weight7 kg
Technical
Rated Operational Voltage208 ... 690 V AC
Rated Control Supply Voltage (Us)100 ... 250 V AC
Rated Control Circuit Voltage (Uc)24 V DC
Rated Frequency (f)50/60 Hz
Main Circuit 50 / 60 Hz
Rated Operational Power - In-Line Connection (Pe)(230 V) 37 kW
(400 V) 75 kW
(500 V) 90 kW
(690 V) 132 kW
Rated Operational Current - In-Line Connection (Ie)142 A
Rated Operational Power - Inside Delta Connectionat 230 V 75 kW
at 400 V 132 kW
at 500 V 160 kW
at 690 V 220 kW
Rated Operational Current - Inside Delta Connection245 A
Service Factor Percentage100 %
Overload ProtectionBuilt-in electronic overload protection
Integrated Electronic OverloadYes
Starting Capacity at Maximum Rated Current Ie4xIe for 10s
Ramp Time1 ... 120 second [unit of time]
Initial Voltage During Start10 ... 99 %
Step Down Voltage Special Ramp100 ... 10 %
Current Limit Function1.5 ... 7.5 xle
Switch for Inside Delta ConnectionYes
Run Signal RelayYes
By-pass Signal RelayYes
Fault Signal RelayYes
Overload Signal RelayYes
Analog Outputs0…10 V, 0…20 mA, 4…20 mA
Signal Indication Ready to Start/Standby ON (LED)Green
Signal Indication Running R (LED)Green
Signal Indication Protection (LED)Yellow
Signal Indication Fault (LED)Red
CommunicationModbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal TypeMain Circuit: Bars
Connecting Capacity Main CircuitHole Diameter 8.5 mm
Connecting Capacity Control CircuitRigid 1 x 2.5 mm²
Connecting Capacity Supply CircuitRigid 1 x 2.5
Tightening TorqueMain Circuit 14 N·m
Product Main TypePSTX142
FunctionAuto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Full voltage start
Jog with slow speed, forward and reverse
Keypad password
Kick start
Limp mode with two-phase motor control if one set of thyristors is shorted
Motor heating
Pre-start function
Pump cleaning
Real time clock
Sequence start
Soft start with torque control
Soft start with voltage ramp
Soft stop with torque control
Soft stop with voltage ramp
Stand still brake
Start reverse (external contactors)
Thyristor runtime measurement
Torque limit
Voltage sags detection
Protection FunctionBypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Warning DetailsCurrent imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
Technical UL/CSA
Horsepower Rating UL/CSA(200 ... 208 V AC) Three Phase 40 Hp
(220 ... 240 V AC) Three Phase 50 Hp
(440 ... 480 V AC) Three Phase 100 Hp
(550 ... 600 V AC) Three Phase 125 Hp
Maximum Operating Voltage UL/CSAMain Circuit 690 V
Tightening Torque UL/CSAMain Circuit 123.9
Environmental
Ambient Air TemperatureOperation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration2CMT2022-006481
RoHS Declaration2CMT2022-006500
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP7ac58c93-1935-4f9a-a1cf-b53a16b37b9e Sweden
Simplified SCIP2c12831e-d227-4343-89cd-8ad9d0598b61 Croatia
2c8d8687-c1c6-45eb-96a8-f71342d2e1f0 Finland
2ef72255-8a48-4f8e-a7b1-313f04b94f51 Germany
347da50a-f271-4da7-8510-8026f1acdea3 Germany
440607c6-b08e-4d6d-bd83-61d6cb8a5e26 Estonia
58839739-518f-4286-8ac2-834169918879 Germany
59a2564a-7755-4843-a2aa-a3a56004e5e9 Denmark
602979df-6621-44e7-8b07-d529d35e25de Czech Republic
6b121e93-34c0-4cc5-8588-2cfd914a2297 Bulgaria
6be3dec0-f89a-43ab-a9bf-4fd7d32b2cfe Italy
7f3a5266-46a0-4bd5-8956-4cb28cf71584 France
86667217-7850-4464-bc67-0989310e6d51 Belgium
8945c0b2-d687-4890-84ec-bfd8b63a6873 Belgium
8de00583-51c1-4c15-921d-cf224e8d6a7b Greece
95cdfb74-c4de-43c9-a407-a32f70a6bc98 Poland
99ee119e-fa5f-497c-961a-89051ecf6b00 Poland
b797e4b8-7518-46e0-ab6f-0e4d1c2aa87a Germany
bf3d4a73-1b3c-451a-b266-236ba7136eed Hungary
c0ef8ad3-55b8-4056-8a87-a33727de619c France
c6ec4ad1-bc67-4e74-b1bd-5e37556b8b4e Norway
c7da1248-c80a-4811-a6a8-195c040a4df8 Sweden
c83eb676-1ff4-412a-af63-9f6fe9b3a126 Poland
c93a6f14-01b7-4e10-8eaf-7b935d98e077 Germany
d0f38e66-e5ff-4c69-a6b4-db6ed0a1dc9b Netherlands
d236d276-4f52-41a5-aad1-8b8367bd7a2b Portugal
de94f801-93d2-454f-b5a5-8d39e3193292 Spain
fa967b40-4d4f-4609-80c5-d1098a8f5331 Hungary
Toxic Substances Control Act - TSCA2CMT2023-006524
WEEE B2C / B2BBusiness To Business
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
CQC CertificateCN: CQC2014010304744407 / SE: CQC2014010304724379
Declaration of Conformity - CCCCN: 2020980304001092 / SE: 2020980304001485
Declaration of Conformity - CE2CMT005209
DNV CertificateTAE000087N
Container Information
Package Level 1 Width263 mm
Package Level 1 Depth / Length323 mm
Package Level 1 Height454 mm
Package Level 1 Gross Weight8.7 kg
Package Level 1 EAN7320500501450
Package Level 1 Unitsbox 1 piece
External Classifications and Standards
Object Classification CodeQ
ETIM 7EC000640 - Soft starter
ETIM 8EC000640 - Soft starter
ETIM 9EC000640 - Soft starter
eClassV11.0 : 27370907
UNSPSC39121521
IDEA Granular Category Code (IGCC)4740 >> Soft starter

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.