ANUNCIAR
1SFA898209R7000 ABB Soft Starter 400V/55kW, 500V/75kW, 690V/90kW, 106A View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

1SFA898209R7000 ABB Soft Starter 400V/55kW, 500V/75kW, 690V/90kW, 106A

1SFA898209R7000

ABB

Soft Starter 400V/55kW, 500V/75kW, 690V/90kW, 106A

PSTX105-690-70 SOFT STARTER

PSTX105-690-70 Softstarter - 105 A - 208 ... 690 V AC

More details


Low-voltage industrial components > Soft starter

Soft Starters > Soft starters PSTX

Brand new product in its original packaging covered by the warranties and certifications provided by ABB

Total: $1,951.54
Unit price: $1,951.54
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Ordering
Minimum Order Quantity1 piece
Customs Tariff Number85371091
Popular Downloads
Data Sheet, Technical Information1SFC132012C0201
Instructions and Manuals1SFC132428M0201
Instructions and Manuals (Part 2)1SFC132081M0201
Instructions and Manuals (Part 3)1SFC132060M0201
CAD Dimensional Drawing2CDC001079B0201
EPLAN Data9AAC181165_EPLAN
Wiring DiagramN/A
Dimensions
Product Net Width150 mm
Product Net Height314 mm
Product Net Depth / Length198 mm
Product Net Weight4.7 kg
Technical
Rated Operational Voltage208 ... 690 V AC
Rated Control Supply Voltage (Us)100 ... 250 V AC
Rated Control Circuit Voltage (Uc)24 V DC
Rated Frequency (f)50/60 Hz
Main Circuit 50 / 60 Hz
Rated Operational Power - In-Line Connection (Pe)(230 V) 30 kW
(400 V) 55 kW
(500 V) 75 kW
(690 V) 90 kW
Rated Operational Current - In-Line Connection (Ie)105 A
Rated Operational Power - Inside Delta Connectionat 230 V 55 kW
at 400 V 90 kW
at 500 V 110 kW
at 690 V 160 kW
Rated Operational Current - Inside Delta Connection181 A
Service Factor Percentage100 %
Overload ProtectionBuilt-in electronic overload protection
Integrated Electronic OverloadYes
Starting Capacity at Maximum Rated Current Ie4xIe for 10s
Ramp Time1 ... 120 second [unit of time]
Initial Voltage During Start10 ... 99 %
Step Down Voltage Special Ramp100 ... 10 %
Current Limit Function1.5 ... 7.5 xle
Switch for Inside Delta ConnectionYes
Run Signal RelayYes
By-pass Signal RelayYes
Fault Signal RelayYes
Overload Signal RelayYes
Analog Outputs0…10 V, 0…20 mA, 4…20 mA
Signal Indication Ready to Start/Standby ON (LED)Green
Signal Indication Running R (LED)Green
Signal Indication Protection (LED)Yellow
Signal Indication Fault (LED)Red
CommunicationModbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal TypeCable Clamp
Connecting Capacity Main CircuitHole Diameter 8.5 mm
Connecting Capacity Control CircuitRigid 1 x 2.5 mm²
Connecting Capacity Supply CircuitRigid 1 x 2.5
Tightening TorqueMain Circuit 8 N·m
Product Main TypePSTX105
FunctionAuto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Full voltage start
Jog with slow speed, forward and reverse
Keypad password
Kick start
Limp mode with two-phase motor control if one set of thyristors is shorted
Motor heating
Pre-start function
Pump cleaning
Real time clock
Sequence start
Soft start with torque control
Soft start with voltage ramp
Soft stop with torque control
Soft stop with voltage ramp
Stand still brake
Start reverse (external contactors)
Thyristor runtime measurement
Torque limit
Voltage sags detection
Protection FunctionBypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Warning DetailsCurrent imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
Technical UL/CSA
Horsepower Rating UL/CSA(200 ... 208 V AC) Three Phase 30 Hp
(220 ... 240 V AC) Three Phase 40 Hp
(440 ... 480 V AC) Three Phase 75 Hp
(550 ... 600 V AC) Three Phase 100 Hp
Maximum Operating Voltage UL/CSAMain Circuit 690 V
Tightening Torque UL/CSAMain Circuit 70.8
Environmental
Ambient Air TemperatureOperation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration2CMT2022-006481
RoHS Declaration2CMT2022-006500
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIPe7940dd6-ebdc-421a-ac15-6f53c066ab8e Sweden
Simplified SCIP0b26b9b3-1b09-4bda-808b-1c558c375102 Portugal
0ecd87f6-0b3d-4907-8e10-b07e53cce57a Greece
0ff651df-9e2c-4fd7-b1e3-7cdaed08d236 Estonia
185e87bb-a37a-47ec-bd3d-a49bd77cbe1f Belgium
26dbf795-797e-4169-9759-e7ad5374af6a Sweden
28ddc28d-3da5-43e8-94da-a1fef8c1eab9 Germany
2ac451b5-ed1c-4476-9960-5ffabd9a0512 Finland
32f62b4f-95d7-4d73-aff3-62825836cebe Norway
3bed07d0-3bb9-44af-a139-581d61ebcd55 Hungary
42618e39-7d5c-43e9-9c94-b18398113682 Poland
4b0c1e22-8250-42b2-85b2-2be2b3907126 Germany
53f68d24-5dc7-4aed-be25-6a92d43375e7 Germany
58568401-1ee5-4bda-92b9-97e38b7e9aee Hungary
7cd4d1f3-bb06-450b-b35d-875203c7f72d France
8697daae-e634-4686-a21d-36ea2c0dac72 Czech Republic
8777ac81-e4a5-4d81-8368-c11520219b5a Germany
8ef52d23-dd29-4c2b-8238-e3befec6b35f Poland
8f2933a9-0358-42b9-976b-1823cdc5cecc Bulgaria
9615b811-0bd3-4002-9062-d525714c5595 Croatia
a8593dc1-700a-43cd-8208-68e0d6de8729 France
ba0882b5-3f8d-416f-b004-0428942396a0 Denmark
bfbd2c7e-2d98-4400-8a70-755f22a45b45 Spain
c780222a-3d86-4656-bd30-fa6943426d29 Belgium
d9ebb58f-6b81-4c30-aa3f-99a3694286dd Italy
ed181487-611b-4185-8e13-39630ba2d6c0 Netherlands
ed52b8d9-4f83-4b16-ab5b-c14b8acb3935 Germany
ee24cbb2-bc7b-487d-8c7d-25111e9ddb8b Poland
Toxic Substances Control Act - TSCA2CMT2023-006524
WEEE B2C / B2BBusiness To Business
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
CQC CertificateCN: CQC2014010304744405 / SE: CQC2014010304724380
Declaration of Conformity - CCCCN: 2020980304001091 / SE: 2020980304001489
Declaration of Conformity - CE2CMT005209
DNV CertificateTAE000087N
Container Information
Package Level 1 Width200 mm
Package Level 1 Depth / Length282 mm
Package Level 1 Height388 mm
Package Level 1 Gross Weight5.7 kg
Package Level 1 EAN7320500501344
Package Level 1 Unitsbox 1 piece
External Classifications and Standards
Object Classification CodeQ
ETIM 7EC000640 - Soft starter
ETIM 8EC000640 - Soft starter
ETIM 9EC000640 - Soft starter
eClassV11.0 : 27370907
UNSPSC39121521
IDEA Granular Category Code (IGCC)4740 >> Soft starter

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.